Characterization of firefighter exposures during fire overhaul

被引:112
作者
Bolstad-Johnson, DM
Burgess, JL
Crutchfield, CD
Storment, S
Gerkin, R
Wilson, JR
机构
[1] City Phoenix Personnel Dept, Safety Sect, Phoenix, AZ 85003 USA
[2] Univ Arizona, Prevent Ctr, Tucson, AZ 85719 USA
[3] City Phoenix Fire Dept, Phoenix, AZ 85034 USA
[4] Arizona State Univ, Tempe, AZ 85287 USA
来源
AIHAJ | 2000年 / 61卷 / 05期
关键词
characterization of hazards during fire overhaul; fire overhaul; fire overhaul contaminants; recommended respiratory protection;
D O I
10.1080/15298660008984572
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Previous studies have characterized firefighter exposures during fire suppression. However, minimal information is available regarding firefighter exposures during overhaul, when firefighters look for hidden fire inside attics, ceilings, and walls, often without respiratory protection. A comprehensive air monitoring study was conducted to characterize City of Phoenix firefighter exposures during the overhaul phase of 25 structure tires. Personal samples were collected for aldehydes; benzene; toluene; ethyl benzene; xylene; hydrochloric acid; polynuclear aromatic hydrocarbons (PNA); respirable dust; and hydrogen cyanide (HCN). Gas analyzers were employed to continuously monitor carbon monoxide (CO), HCN, nitrogen dioxide (NO2), and sulfur dioxide (SO2). Area samples were collected for asbestos, metals (Cd, Cr, Pb), and total dust. During overhaul the following exceeded published ceiling values: acrolein (American Conference of Governmental Industrial Hygienists [ACGIH (R)] 0.1 ppm) at 1 fire; CO (National Institute for Occupational Safety and Health [NIOSH] 200 ppm) at 5 fires; formaldehyde (NIOSH 0.1 ppm) at 22 fires; and glutaraldehyde (ACGIH 0.05 ppm) at 5 fires. In addition, the following exceeded published short-term exposure limit values: benzene (NIOSH 1 ppm) at two fires, NO2 (NIOSH 1 ppm) at two fires, and SO2 (ACGIH 5 ppm) at five fires. On an additive effects basis, PNA concentrations exceeded the NIOSH recommended exposure limits (0.1 mg/M-3) for coal tar pitch volatiles at two fires. Maximum concentrations of other sampled substances were below their respective permissible exposure limits. Initial 10-min average CO concentrations did not predict concentrations of other products of combustion. The results indicate that firefighters should use respiratory protection during overhaul. In addition, these findings suggest that CO should not be used as an indicator gas for other contaminants found in this atmosphere.
引用
收藏
页码:636 / 641
页数:6
相关论文
共 11 条
  • [1] *ACGIH, 1998, 1998 TLVS BEIS THRES
  • [2] Longitudinal decline in measured firefighter single-breath diffusing capacity of carbon monoxide values - A respiratory surveillance dilemma
    Burgess, JL
    Brodkin, CA
    Daniell, WE
    Pappas, GP
    Keifer, MC
    Stover, BD
    Edland, SD
    Barnhart, S
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1999, 159 (01) : 119 - 124
  • [3] MINIMUM PROTECTION FACTORS FOR RESPIRATORY PROTECTIVE DEVICES FOR FIREFIGHTERS
    BURGESS, WA
    SIDOR, R
    LYNCH, JJ
    BUCHANAN, P
    CLOUGHERTY, E
    [J]. AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1977, 38 (01): : 18 - 23
  • [4] ELLER PM, 1994, DHHS NIOSH PUBLICATI
  • [5] EXPOSURE OF FIREFIGHTERS TO TOXIC AIR CONTAMINANTS
    GOLD, A
    BURGESS, WA
    CLOUGHERTY, EV
    [J]. AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1978, 39 (07): : 534 - 539
  • [6] HARTZELL GE, 1983, AM IND HYG ASSOC J, V44, P248, DOI 10.1080/15298668391404743
  • [7] REGULATORY ASPECTS OF FIRE TOXICOLOGY
    NELSON, GL
    [J]. TOXICOLOGY, 1987, 47 (1-2) : 181 - 199
  • [8] *NIOSH, 1998, 9601712692 NIOSH HET
  • [9] *NIOSH, 1997, DHHS NIOSH PUBL
  • [10] STORMENT S, 1998, COMMUNICATION 0105