Real-time monitoring of the tablet-coating process by near-infrared spectroscopy - Effects of coating polymer concentrations on pharmaceutical properties of tablets

被引:29
|
作者
Hattori, Yusuke [1 ]
Sugata, Misuzu [1 ]
Kamata, Hitoshi [2 ]
Nagata, Makoto [2 ]
Nagato, Takuya [2 ]
Hasegawa, Kouji [2 ]
Otsuka, Makoto [1 ]
机构
[1] Musashino Univ, Fac Pharm, 1-1-20 Shinmachi, Nishi Tokyo 2028585, Japan
[2] Powrex Corp, 121-1 Kita Itami 8 Chome, Itami, Hyogo 6640831, Japan
关键词
Quality-by-Design; Real-time monitoring; In-line near-infrared spectroscopy; EUDRAGIT((R)); Partial least-squares regression; Table-coating process; NIR SPECTROSCOPY; FILM THICKNESS; RELEASE; PREDICTION; DISSOLUTION; SYSTEM;
D O I
10.1016/j.jddst.2018.04.018
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
In order to establish a pharmaceutical manufacturing process control system based on a Quality-by-Design concept, the pharmaceutical properties of tablets during the tablet-coating process were monitored in real time and predicted using values recorded by in-line near-infrared (NIR) spectroscopy. Coating amount (C%), thickness (L), tablet hardness (HT), and tablet dissolution parameters with elution times (T-0, T-50, and T-80) were measured using individual pharmaceutical tests. Tablet coating was performed by spraying F-A (25 w/w%) or F-B (17.8 w/w%) containing EUDRAGIT((R)) L 30 D-55, and monitored using an in-line NIR spectroscopy instrument. Calibration models to predict tablet properties (C%, L, HT, T-0, T-50, and T-80) were obtained based on NIR spectroscopy using a partial least-squares regression (PLS). Chemometric parameters were found to be sufficiently accurate. Correlations between the predicted and measured values of each tablet property showed satisfactory linear relationships. Therefore, the pharmaceutical properties (C%, L, HT, T-0, T-50, and T-80) of tablets may be monitored in real time during the coating process with an in-line NIR spectroscopy method.
引用
收藏
页码:111 / 121
页数:11
相关论文
共 50 条
  • [31] Real-time imaging as an emerging process analytical technology tool for monitoring of fluid bed coating process
    Naidu, Venkata Ramana
    Deshpande, Rucha S.
    Syed, Moinuddin R.
    Wakte, Pravin S.
    PHARMACEUTICAL DEVELOPMENT AND TECHNOLOGY, 2018, 23 (06) : 596 - 601
  • [32] Real-Time Monitoring of Critical Quality Attributes during High-Shear Wet Granulation Process by Near-Infrared Spectroscopy Effect of Water Addition and Stirring Speed on Pharmaceutical Properties of the Granules
    Koyanagi, Keita
    Ueno, Akinori
    Sasaki, Tetsuo
    Otsuka, Makoto
    PHARMACEUTICALS, 2022, 15 (07)
  • [33] Integration of Near-Infrared Spectroscopy and Mechanistic Modeling for Predicting Film-Coating and Dissolution of Modified Release Tablets
    Wu, Huiquan
    Lyon, Robbe C.
    Khan, Mansoor A.
    Voytilla, Randall J.
    Drennen, James K., III
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2015, 54 (22) : 6012 - 6023
  • [34] Real-time monitoring of the column chromatography process of Ginkgo biloba using near-infrared and Raman spectroscopy combined with spectral fusion strategy
    Zhang, Sijie
    Zhang, Sheng
    Gong, Xingchu
    Qu, Haibin
    PROCESS BIOCHEMISTRY, 2024, 145 : 50 - 62
  • [35] Real-time monitoring prefrontal activities during online video game playing by functional near-infrared spectroscopy
    Li, Yue
    Zhang, Lei
    Long, Kehong
    Gong, Hui
    Lei, Hao
    JOURNAL OF BIOPHOTONICS, 2018, 11 (09)
  • [36] A Non-invasive Real-Time Methodology for the Quantification of Antioxidant Properties in Coffee During the Roasting Process Based on Near-Infrared Spectroscopy
    Tiago A. Catelani
    Ricardo N. M. J. Páscoa
    João Rodrigo Santos
    Leonardo Pezza
    Helena R. Pezza
    José L. F. C. Lima
    João A. Lopes
    Food and Bioprocess Technology, 2017, 10 : 630 - 638
  • [37] A Non-invasive Real-Time Methodology for the Quantification of Antioxidant Properties in Coffee During the Roasting Process Based on Near-Infrared Spectroscopy
    Catelani, Tiago A.
    Pascoa, Ricardo N. M. J.
    Santos, Joao Rodrigo
    Pezza, Leonardo
    Pezza, Helena R.
    Lima, Jose L. F. C.
    Lopes, Joao A.
    FOOD AND BIOPROCESS TECHNOLOGY, 2017, 10 (04) : 630 - 638
  • [38] Light leakage effects with different sample holder geometries in quantitative near-infrared transmission spectroscopy of pharmaceutical tablets
    Sparén, A
    Malm, M
    Josefson, M
    Folestad, S
    Johansson, J
    APPLIED SPECTROSCOPY, 2002, 56 (05) : 586 - 592
  • [39] Real-time and field monitoring of the key parameters in industrial trough composting process using a handheld near infrared spectrometer
    Huang, Yuanping
    Sun, Xiaoxi
    Liao, Keke
    Han, Lujia
    Yang, Zengling
    JOURNAL OF NEAR INFRARED SPECTROSCOPY, 2020, 28 (5-6) : 334 - 343
  • [40] Real-time monitoring of integrated continuous granulation/drying line system " LaVortex ®" for the pharmaceutical manufacturing of acetaminophen oral dosage formulations using near-infrared spectroscopy
    Koyanagi, Keita
    Shoji, Kippei
    Ueno, Akinori
    Sasaki, Tetsuo
    Otsuka, Makoto
    JOURNAL OF DRUG DELIVERY SCIENCE AND TECHNOLOGY, 2024, 101