A comparative evaluation of three accelerometry-based physical activity monitors

被引:241
作者
Welk, GJ
Blair, SN
Wood, K
Jones, S
Thompson, RW
机构
[1] Iowa State Univ, Dept Hlth & Human Performance, Ames, IA 50011 USA
[2] Cooper Inst, Dallas, TX 75230 USA
关键词
physical activity assessment; motion sensors; CSA; Tritrac; biotrainer;
D O I
10.1097/00005768-200009001-00008
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Purpose: Accelerometry-based activity monitors offer promise for the assessment of free-living physical activity. They provide an objective record of frequency, intensity, and duration of physical activity with minimal burden on participants. The purpose of this study was to evaluate the absolute and relative validity of three contemporary activity monitors (Computer Science and Applications, Inc. [CSA], Tritrac, and Biotrainer) under both laboratory and field conditions. Methods: Fifty-two participants completed two 30-min choreographed routines designed to simulate a variety of lifestyle physical activities. Three different treadmill paces were completed in both routines to evaluate reliability and validity under laboratory conditions. Six different lifestyle activities were also examined to evaluate the validity of the monitors under field conditions. During each routine, the activity levels of participants were monitored with the three activity monitors as well as by indirect calorimetry systems. Results: The correlations between the monitors and measured (V)over dotO(2) were higher for treadmill activity (mean r = 0.86) compared with lifestyle activity (mean r = 0.55). Correlations among the different monitors were high for both treadmill (r = 0.86) and lifestyle activities (r = 0.70), suggesting that the monitors provide similar information under both conditions. Under laboratory conditions, the CSA yielded accurate predictions of energy expenditure (EE), whereas the Tritrac and Biotrainer tended to overestimate the EE (101-136% of measured value). The Tritrac, however, was found to have less error in individual estimates of EE. Under field conditions, all of the monitors underestimated EE (range: 42-67% of measured value). Conclusion: The observed differences among the monitors were attributed primarily to differences in the accuracy of the calibration equations rather than to the monitors themselves. Further research is needed to better understand how to use these devices for field-based assessments of physical activity.
引用
收藏
页码:S489 / S497
页数:9
相关论文
共 27 条
[1]   COMPENDIUM OF PHYSICAL ACTIVITIES - CLASSIFICATION OF ENERGY COSTS OF HUMAN PHYSICAL ACTIVITIES [J].
AINSWORTH, BE ;
HASKELL, WL ;
LEON, AS ;
JACOBS, DR ;
MONTOYE, HJ ;
SALLIS, JF ;
PAFFENBARGER, RS .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1993, 25 (01) :71-80
[2]  
AINSWORTH BE, 1994, PHYSICAL ACTIVITY FI, P146
[3]  
[Anonymous], PEDIAT EXERCISE SCI
[4]  
[Anonymous], 1996, PHYS ACT HLTH REP SU
[5]   CALORIMETRIC VALIDATION OF THE CALTRAC ACCELEROMETER DURING LEVEL WALKING [J].
BALOGUN, JA ;
MARTIN, DA ;
CLENDENIN, MA .
PHYSICAL THERAPY, 1989, 69 (06) :501-509
[6]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[7]   Daily physical activity assessment: Comparison between movement registration and doubly labeled water [J].
Bouten, CVC ;
VerboeketVandeVenne, WPHG ;
Westerterp, KR ;
Verduin, M ;
Janssen, JD .
JOURNAL OF APPLIED PHYSIOLOGY, 1996, 81 (02) :1019-1026
[8]   Effects of placement and orientation of body-fixed accelerometers on the assessment of energy expenditure during walking [J].
Bouten, CVC ;
Sauren, AAHJ ;
Verduin, M ;
Janssen, JD .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1997, 35 (01) :50-56
[9]  
BRAY MS, 1994, MED SCI SPORT EXER, V26, P1524
[10]   Validity of heart rate, pedometry, and accelerometry for predicting the energy cost of children's activities [J].
Eston, RG ;
Rowlands, AV ;
Ingledew, DK .
JOURNAL OF APPLIED PHYSIOLOGY, 1998, 84 (01) :362-371