The utility of bispectral index monitoring in flexible bronchoscopy: A single-center, retrospective observational study

被引:5
|
作者
Yamada, Jun [1 ]
Hazama, Daisuke [1 ]
Tachihara, Motoko [1 ]
Kawanami, Yuki [2 ]
Kawaguchi, Aki [1 ]
Yatani, Atsuhiko [1 ]
Sato, Hiroki [1 ]
Mimura, Chihiro [1 ]
Katsurada, Naoko [1 ]
Yamamoto, Masatsugu [1 ]
Nishimura, Yoshihiro [1 ]
Kobayashi, Kazuyuki [1 ]
机构
[1] Kobe Univ, Dept Internal Med, Div Resp Med, Grad Sch Med, Kobe, Hyogo, Japan
[2] Kobe Univ Hosp, Dept Clin Engn, Kobe, Hyogo, Japan
关键词
BIS value; flexible bronchoscopy; MOAA; S score; sedation; SEDATION SCALE; PROPOFOL;
D O I
10.1111/1759-7714.14658
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background The desired depth of sedation during flexible bronchoscopy is one in which verbal contact is possible whenever necessary. Although it is common that the depth of sedation is assessed by validated instruments such as the modified observer's assessment of alertness and sedation (MOAA/S) score, the repeated stimulation associated with the assessment can affect the sedation. The bispectral index (BIS) has been widely used for general anesthesia due to its objective and noninvasive nature. However, the utility of BIS monitoring and a target BIS value for use during bronchoscopy have not been fully elucidated. Methods We performed a retrospective observational study to assess the utility of the BIS value for monitoring conscious sedation during bronchoscopy at Kobe University Hospital from August 2020 to April 2021. Results Eighteen patients underwent bronchoscopy with BIS monitoring. The BIS value significantly correlated with the MOAA/S score (r = 0.2, p < 0.01), and the correlation was stronger in sufficiently sedated patients (r = 0.486, p < 0.01). The lowest MOAA/S score during the procedure was highly correlated with the BIS value (r = 0.625, p < 0.01). The BIS monitoring seemed to be more sensitive to changes in the sedation level than the MOAA/S score, heart rate and mean arterial pressure. The median BIS value at an MOAA/S score of 3-4, the desired depth of sedation, was 82.0. Conclusions BIS value is useful for monitoring sedation during bronchoscopy. This study suggests that a BIS value of 82 reflects an adequate level of sedation.
引用
收藏
页码:3052 / 3057
页数:6
相关论文
共 50 条
  • [1] Bispectral Index Monitoring of Midazolam Sedation During Flexible Bronchoscopy
    Yamamoto, Shinichi
    Igarashi, Takashi
    Tetsuka, Kenji
    Endo, Shunsuke
    JOURNAL OF BRONCHOLOGY & INTERVENTIONAL PULMONOLOGY, 2009, 16 (04) : 241 - 244
  • [2] Utility of Flexible Bronchoscopy as an Interventional Tool in Children: A Single-Center Cross-Sectional Study
    Bhat, Javeed Iqbal
    Tramboo, Zubair Mushtaq
    Zargar, Shahan Iqbal
    Maqsood, Shadab
    Charoo, Bashir Ahmad
    JOURNAL OF PEDIATRIC INTENSIVE CARE, 2024,
  • [3] Pulmonary infections mimicking malignancy on bronchoscopy: A retrospective single-center study in Japan
    Itoh, Naoya
    Shimizu, Junichi
    Murakami, Hiromi
    Hida, Toyoaki
    JOURNAL OF GENERAL AND FAMILY MEDICINE, 2021, 22 (01): : 38 - 42
  • [4] Prospective Randomized Trial of Bispectral Index Monitoring of Sedation Depth during Flexible Bronchoscopy
    Fruchter, Oren
    Tirosh, Michal
    Carmi, Uri
    Rosengarten, Dror
    Kramer, Mordechai R.
    RESPIRATION, 2014, 87 (05) : 388 - 393
  • [5] Bispectral Index Monitoring: Validity and Utility in Pediatric Dentistry
    Goyal, A.
    Mittal, N.
    Mittal, P.
    Gauba, K.
    JOURNAL OF CLINICAL PEDIATRIC DENTISTRY, 2014, 38 (04) : 366 - 369
  • [6] Bispectral index monitoring: Optimizing anesthesia in rigid bronchoscopy
    Adiyeke, Ozal
    Sarban, Onur
    Mendes, Ergun
    Akca, Hilal
    Turan, Engin Ihsan
    Demirkol, Baris
    Ozgul, Mehmet Akif
    Gumus Ozcan, Funda
    TUBERKULOZ VE TORAKS-TUBERCULOSIS AND THORAX, 2024, 72 (03):
  • [7] A randomised study of comfort during bronchoscopy comparing conscious sedation and anaesthetist-controlled general anaesthesia, including the utility of bispectral index monitoring
    Skinner, Thomas R.
    Churton, Joseph
    Edwards, Timothy P.
    Bashirzadeh, Farzad
    Zappala, Christopher
    Hundloe, Justin T.
    Tan, Hau
    Pattison, Andrew J.
    Todman, Maryann
    Hartel, Gunter F.
    Fielding, David, I
    ERJ OPEN RESEARCH, 2021, 7 (02)
  • [8] Safety and efficacy of remimazolam compared with midazolam during bronchoscopy: a single-center, randomized controlled study
    Kim, Sun-Hyung
    Cho, Jun Yeun
    Kim, Miyeon
    Chung, Ji Min
    Yang, Jiyoul
    Seong, Changhwan
    Kim, Eung-Gook
    Seok, Jeong Won
    Shin, Yoon Mi
    Lee, Ki Man
    Choe, Kang Hyeon
    Han, Joung-Ho
    Yang, Bumhee
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [9] The Insertion of Self Expanding Metal Stents With Flexible Bronchoscopy Under Sedation for Malignant Tracheobronchial Stenosis: A Single-Center Retrospective Analysis
    McGrath, Emmet E.
    Warriner, David
    Anderson, Paul
    ARCHIVOS DE BRONCONEUMOLOGIA, 2012, 48 (02): : 43 - 48
  • [10] Risk factors associated with reintubations in children undergoing foreign body removal using flexible bronchoscopy: a single-center retrospective cross-sectional study
    Su-Jing Zhang
    Hong-Bin Gu
    Min Zhou
    Min-Yi Lin
    Long-Xin Zhang
    Xiu-Ying Chen
    Guo-Lin Lu
    BMC Anesthesiology, 22