Colloidal gold as an electrochemical label of streptavidin-biotin interaction

被引:75
作者
González-García, MB [1 ]
Fernández-Sánchez, C [1 ]
Costa-García, A [1 ]
机构
[1] Univ Oviedo, Dept Quim Fis & Analit, Oviedo 33006, Spain
关键词
carbon paste electrode; colloidal gold; streptavidin; biotin; adsorptive voltammetry;
D O I
10.1016/S0956-5663(00)00074-9
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A new electrochemical method to monitor biotin-streptavidin interaction, based on the use of colloidal gold as an electrochemical label, is investigated. Biotinylated albumin is adsorbed on the pretreated surface of a carbon paste electrode (CPE). This modified electrode is immersed in colloidal gold-streptavidin labelled solutions. Adsorptive voltammetry is used to monitor colloidal gold bound to streptavidin, obtaining a good reproducibility of the analytical signal (R.S.D. = 3.3%). A linear relationship between peak current and streptavidin concentration from 2.5 x 10(-9) to 2.5 x 10(-5) M is obtained when a sequential competitive assay between streptavidin and colloidal gold-labelled streptavidin is carried out. On the other hand, the adsorption of streptavidin on the electrode surface was performed, followed by the reaction with biotinylated albumin labelled with colloidal gold. In this way, a linear relationship between peak current and colloidal gold labelled biotinylated albumin concentration is achieved with a limit of detection of 7.3 x 10(9) gold particles per ml (5.29 x 10(-9) M in biotin). (C) 2000 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:315 / 321
页数:7
相关论文
共 24 条
  • [1] AVIDIN-BIOTIN COMPLEXATION FOR ENZYME SENSOR APPLICATIONS
    ANZAI, J
    HOSHI, T
    OSA, T
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1994, 13 (05) : 205 - 210
  • [2] AVIDIN-BIOTIN BASED ELECTROCHEMICAL IMMUNOASSAY FOR THYROTROPIN
    ATHEY, D
    BALL, M
    MCNEIL, CJ
    [J]. ANNALS OF CLINICAL BIOCHEMISTRY, 1993, 30 : 570 - 577
  • [3] BEESLEY JE, 1988, SCANNING MICROSCOPY, V2, P1055
  • [4] ANODIC DEPOSITION OF COLLOIDAL GOLD
    DESPIC, AR
    PAVLOVIC, MG
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1984, 180 (1-2) : 31 - 40
  • [5] FAULK WP, 1971, IMMUNOCHEMISTRY, V8, P1081
  • [6] Gonzalez Garcia M. B., 1995, Bioelectrochemistry and Bioenergetics, V38, P389, DOI 10.1016/0302-4598(95)01813-T
  • [7] Green N M, 1975, Adv Protein Chem, V29, P85, DOI 10.1016/S0065-3233(08)60411-8
  • [8] COLLOIDAL GOLD GRANULES AS MARKERS FOR CELL-SURFACE RECEPTORS IN SCANNING ELECTRON-MICROSCOPE
    HORISBERGER, M
    ROSSET, J
    BAUER, H
    [J]. EXPERIENTIA, 1975, 31 (10): : 1147 - 1149
  • [9] HORISBERGER M, 1981, SCANNING ELECTRON MI, V2, P9
  • [10] ELECTROCHEMICAL DEPOSITION OF AVIDIN ON THE SURFACE OF A PLATINUM-ELECTRODE FOR ENZYME SENSOR APPLICATIONS
    HOSHI, T
    ANZAI, J
    OSA, T
    [J]. ANALYTICA CHIMICA ACTA, 1994, 289 (03) : 321 - 327