Colloidal gold as an electrochemical label of streptavidin-biotin interaction

被引:75
|
作者
González-García, MB [1 ]
Fernández-Sánchez, C [1 ]
Costa-García, A [1 ]
机构
[1] Univ Oviedo, Dept Quim Fis & Analit, Oviedo 33006, Spain
来源
BIOSENSORS & BIOELECTRONICS | 2000年 / 15卷 / 5-6期
关键词
carbon paste electrode; colloidal gold; streptavidin; biotin; adsorptive voltammetry;
D O I
10.1016/S0956-5663(00)00074-9
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A new electrochemical method to monitor biotin-streptavidin interaction, based on the use of colloidal gold as an electrochemical label, is investigated. Biotinylated albumin is adsorbed on the pretreated surface of a carbon paste electrode (CPE). This modified electrode is immersed in colloidal gold-streptavidin labelled solutions. Adsorptive voltammetry is used to monitor colloidal gold bound to streptavidin, obtaining a good reproducibility of the analytical signal (R.S.D. = 3.3%). A linear relationship between peak current and streptavidin concentration from 2.5 x 10(-9) to 2.5 x 10(-5) M is obtained when a sequential competitive assay between streptavidin and colloidal gold-labelled streptavidin is carried out. On the other hand, the adsorption of streptavidin on the electrode surface was performed, followed by the reaction with biotinylated albumin labelled with colloidal gold. In this way, a linear relationship between peak current and colloidal gold labelled biotinylated albumin concentration is achieved with a limit of detection of 7.3 x 10(9) gold particles per ml (5.29 x 10(-9) M in biotin). (C) 2000 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:315 / 321
页数:7
相关论文
共 50 条
  • [1] Energy landscape roughness of the streptavidin-biotin interaction
    Rico, Felix
    Moy, Vincent T.
    JOURNAL OF MOLECULAR RECOGNITION, 2007, 20 (06) : 495 - 501
  • [2] Shotgun scanning the streptavidin-biotin interaction.
    Weiss, GA
    Avrantinis, SK
    Stafford, RL
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2002, 224 : U166 - U166
  • [3] Visualisation of the streptavidin-biotin interaction using AFM
    Neish, CS
    Henderson, RM
    Edwardson, JM
    BIOPHYSICAL JOURNAL, 2002, 82 (01) : 337A - 337A
  • [4] Shotgun scanning the streptavidin-biotin interaction.
    Weiss, GA
    Avrantinis, SK
    Stafford, RL
    BIOCHEMISTRY, 2002, 41 (28) : 8977 - 8977
  • [5] Direct force measurements of the streptavidin-biotin interaction
    Wong, J
    Chilkoti, A
    Moy, VT
    BIOMOLECULAR ENGINEERING, 1999, 16 (1-4): : 45 - 55
  • [6] Electrochemical assay of nonlabeled DNA chip and SNOM imaging by using streptavidin-biotin interaction
    Lee, HY
    Park, JW
    Jung, HS
    Kim, JM
    Kawai, T
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2004, 4 (07) : 882 - 885
  • [7] Dissecting streptavidin-biotin interaction with a Laminar flow chamber
    Pierres, A
    Touchard, D
    Benoliel, AM
    Bongrand, P
    BIOPHYSICAL JOURNAL, 2002, 82 (06) : 3214 - 3223
  • [8] Streptavidin-biotin binding energetics
    Stayton, PS
    Freitag, S
    Klumb, LA
    Chilkoti, A
    Chu, V
    Penzotti, JE
    To, R
    Hyre, D
    Le Trong, I
    Lybrand, TP
    Stenkamp, RE
    BIOMOLECULAR ENGINEERING, 1999, 16 (1-4): : 39 - 44
  • [9] Kinetic Stability of the Streptavidin-Biotin Interaction Enhanced in the Gas Phase
    Deng, Lu
    Broom, Aron
    Kitova, Elena N.
    Richards, Michele R.
    Zheng, Ruixiang Blake
    Shoemaker, Glen K.
    Meiering, Elizabeth M.
    Klassen, John S.
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2012, 134 (40) : 16586 - 16596
  • [10] Determination of biotin in foodstuffs and pharmaceutical preparations using a biosensing system based on the streptavidin-biotin interaction
    Reyes, FD
    Romero, JMF
    de Castro, MDL
    ANALYTICA CHIMICA ACTA, 2001, 436 (01) : 109 - 117