High loop rate adaptive optics flood illumination ophthalmoscope with structured illumination capability

被引:23
作者
Gofas-Salas, Elena [1 ,2 ,6 ]
Mece, Pedro [1 ,3 ,6 ]
Petit, Cyril [1 ,6 ]
Jarosz, Jessica [1 ,3 ]
Mugnier, Laurent M. [1 ]
Bonnefois, Aurelie Montmerle [1 ]
Grieve, Kate [2 ,4 ,6 ]
Sahel, Jose [2 ,4 ,5 ]
Paques, Michel [2 ,4 ,6 ]
Meimon, Serge [1 ,6 ]
机构
[1] Univ Paris Saclay, ONERA, DOTA, F-91123 Palaiseau, France
[2] UPMC Univ Paris 06, Sorbonne Univ, Inst Vis, INSERM,CNRS, 17 Rue Moreau, F-75012 Paris, France
[3] Quantel Med, Cournon Dauvergne, France
[4] Quinze Vingts Hosp, INSERM, CIC 1423, Paris, France
[5] Univ Pittsburgh, Sch Med, Dept Ophthalmol, Pittsburgh, PA 15213 USA
[6] PARIS Grp Paris Adapt Opt Retinal Imaging & Surg, Paris, France
基金
欧盟地平线“2020”;
关键词
RETINAL IMAGES; RESOLUTION; REGISTRATION; LIGHT; EYE;
D O I
10.1364/AO.57.005635
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The design and performance of an adaptive optics flood illumination ophthalmoscope (AO-FIO) platform, based on eye motion and dynamic aberrations experimental analysis, are described. The system incorporates a custom-built real-time controller, enabling up to 70 Hz loop rate without jitter, and an AO-corrected illumination capable of projecting high-resolution features in the retina. Wide-field (2.7 degrees x 5.4 degrees) and distortionless images from vessel walls, capillaries, and the lamina cribrosa are obtained with an enhanced contrast and signal-to-noise ratio, thanks to careful control of AO parameters. The high spatial and temporal resolution (image acquisition up to 200 Hz) performance achieved by this platform enables the visualization of vessel deformation and blood flow. This system opens up the prospect of a return to favor of flood illumination adaptive optics systems provided that its high pixel rate and structured illumination capabilities are exploited. (C) 2018 Optical Society of America
引用
收藏
页码:5635 / 5642
页数:8
相关论文
共 26 条
  • [21] Adaptive optics scanning laser ophthalmoscopy
    Roorda, A
    Romero-Borja, F
    Donnelly, WJ
    Queener, H
    Hebert, TJ
    Campbell, MCW
    [J]. OPTICS EXPRESS, 2002, 10 (09): : 405 - 412
  • [22] The arrangement of the three cone classes in the living human eye
    Roorda, A
    Williams, DR
    [J]. NATURE, 1999, 397 (6719) : 520 - 522
  • [23] Roorda A, 2000, J REFRACT SURG, V16, pS602
  • [24] Sauvage J.-F, 2016, Proc. SPIE, V9909
  • [25] Theoretical modeling and evaluation of the axial resolution of the adaptive optics scanning laser ophthalmoscope
    Venkateswaran, K
    Roorda, A
    Romero-Borja, F
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2004, 9 (01) : 132 - 138
  • [26] Imaging microscopic structures in pathological retinas using a flood-illumination adaptive optics retinal camera
    Viard, Clement
    Nakashima, Kiyoko
    Lamory, Barbara
    Paques, Michel
    Levecq, Xavier
    Chateau, Nicolas
    [J]. OPHTHALMIC TECHNOLOGIES XXI, 2011, 7885