Incorporating Cone-Beam CT Into the Diagnostic Algorithm for Suspected Radiocarpal Fractures: A New Standard of Care?

被引:27
|
作者
Gibney, Brian [1 ]
Smith, Michelle [2 ]
Moughty, Adrian [3 ]
Kavanagh, Eoin C. [1 ,4 ]
Hynes, Darragh [2 ,4 ]
MacMahon, Peter J. [1 ,4 ]
机构
[1] Mater Misericordiae Univ Hosp, Dept Radiol, Whitty Bldg,N Circular Rd, Dublin D07 R2WY, Ireland
[2] Mater Misericordiae Univ Hosp, Dept Orthopaed Surg, Dublin, Ireland
[3] Mater Misericordiae Univ Hosp, Emergency Dept, Dublin, Ireland
[4] Univ Coll Dublin, Sch Med, Dublin, Ireland
关键词
cone-beam CT; diagnosis; trauma; wrist; OCCULT SCAPHOID FRACTURES; CONVENTIONAL RADIOGRAPHY; COMPUTED-TOMOGRAPHY; COST-EFFECTIVENESS; WRIST FRACTURES; SENSITIVITY; SYSTEM; MDCT; MRI;
D O I
10.2214/AJR.19.21478
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to assess the result of adding cone-beam CT to the standard imaging algorithm for patients with suspected radiographically occult traumatic radiocarpal fractures. SUBJECTS AND METHODS. A prospective review was performed on all patients who had cone-beam CT investigation of acute wrist pain after normal initial radiographs. Patients with no identified fractures were clinically reassessed and referred for MRI if concern for a fracture persisted. RESULTS. In all, 117 patients were assessed; 50.4% had fractures identified with a total of 67 radiographically occult fractures. One fracture was identified on MRI that was not seen on cone-beam CT. Cone-beam CT had sensitivity of 98.3% (95% CI, 91.1-100%), specificity of 100% (95% CI, 93.7-100%), positive predictive value of 100%, and negative predictive value of 98.3% (95% CI, 89.1-100%). Accuracy was 99.1% (95% CI, 95.3-100%). CONCLUSION. Incorporating cone-beam CT into routine clinical practice as part of a standardized diagnostic algorithm yielded a 50% fracture detection rate in patients with negative wrist radiographs but ongoing clinical concern for radiocarpal fracture. Cone-beam CT provides more diagnostic information than radiographs at a lower radiation dose than conventional MDCT. Given the poor accuracy of radiographs for acute radiocarpal fractures and the high fracture prevalence in this cohort, we feel that cone-beam CT should be regarded as the new standard of care in the investigation of these patients.
引用
收藏
页码:1117 / 1123
页数:7
相关论文
共 50 条
  • [41] 3D cone-beam CT guidance, a novel technique in renal biopsy-results in 41 patients with suspected renal masses
    Braak, Sicco J.
    van Melick, Harm H. E.
    Onaca, Mircea G.
    van Heesewijk, Johannes P. M.
    van Strijen, Marco J. L.
    EUROPEAN RADIOLOGY, 2012, 22 (11) : 2547 - 2552
  • [42] Comparative diagnostic yield of cone beam CT reconstruction using various software programs on the detection of vertical root fractures
    Melo, S. L. S.
    Haiter-Neto, F.
    Correa, L. R.
    Scarfe, W. C.
    Farman, A. G.
    DENTOMAXILLOFACIAL RADIOLOGY, 2013, 42 (09)
  • [43] Generative Noise Reduction in Dental Cone-Beam CT by a Selective Anatomy Analytic Iteration Reconstruction Algorithm
    Dao-Ngoc, Lam
    Du, Yi-Chun
    ELECTRONICS, 2019, 8 (12)
  • [44] Sparse-View Cone-Beam CT Reconstruction by Bar-by-Bar Neural FDK Algorithm
    Wang, Siqi
    Yatagawa, Tatsuya
    Ohtake, Yutaka
    Suzuki, Hiromasa
    NONDESTRUCTIVE TESTING AND EVALUATION, 2024, 39 (02) : 310 - 332
  • [45] A curve-filtered FDK (C-FDK) reconstruction algorithm for circular cone-beam CT
    Li, Liang
    Xing, Yuxiang
    Chen, Zhiqiang
    Zhang, Li
    Kang, Kejun
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2011, 19 (03) : 355 - 371
  • [46] Algorithm-enabled exploration of image-quality potential of cone-beam CT in image-guided radiation therapy
    Han, Xiao
    Pearson, Erik
    Pelizzari, Charles
    Al-Hallaq, Hania
    Sidky, Emil Y.
    Bian, Junguo
    Pan, Xiaochuan
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (12): : 4601 - 4633
  • [47] Filtering path variable FDK (v-FDK) reconstruction algorithm for circular cone-beam CT
    Wang, Chen
    Tan, Bo-zhong
    Yang, Qing-guo
    Li, Ze-ren
    2019 INTERNATIONAL CONFERENCE ON OPTICAL INSTRUMENTS AND TECHNOLOGY: IRMMW-THZ TECHNOLOGIES AND APPLICATIONS, 2020, 11441
  • [48] Shading correction algorithm for cone-beam CT in radiotherapy: Extensive clinical validation of image quality improvement
    Joshi, K. D.
    Marchant, T. E.
    Moore, C. J.
    MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING, 2017, 10132
  • [49] Geometric 3D analyses of the foot and ankle using weight-bearing and non weight-bearing cone-beam CT images: The new standard?
    Broos, M.
    Berardo, S.
    Dobbe, J. G. G.
    Maas, M.
    Streekstra, G. J.
    Wellenberg, R. H. H.
    EUROPEAN JOURNAL OF RADIOLOGY, 2021, 138
  • [50] A novel calibration method incorporating nonlinear optimization and ball-bearing markers for cone-beam CT with a parameterized trajectory
    Li, Guang
    Luo, Shouhua
    You, Chenyu
    Getzin, Matthew
    Zheng, Liang
    Wang, Ge
    Gu, Ning
    MEDICAL PHYSICS, 2019, 46 (01) : 152 - 164