Incorporating Cone-Beam CT Into the Diagnostic Algorithm for Suspected Radiocarpal Fractures: A New Standard of Care?

被引:27
|
作者
Gibney, Brian [1 ]
Smith, Michelle [2 ]
Moughty, Adrian [3 ]
Kavanagh, Eoin C. [1 ,4 ]
Hynes, Darragh [2 ,4 ]
MacMahon, Peter J. [1 ,4 ]
机构
[1] Mater Misericordiae Univ Hosp, Dept Radiol, Whitty Bldg,N Circular Rd, Dublin D07 R2WY, Ireland
[2] Mater Misericordiae Univ Hosp, Dept Orthopaed Surg, Dublin, Ireland
[3] Mater Misericordiae Univ Hosp, Emergency Dept, Dublin, Ireland
[4] Univ Coll Dublin, Sch Med, Dublin, Ireland
关键词
cone-beam CT; diagnosis; trauma; wrist; OCCULT SCAPHOID FRACTURES; CONVENTIONAL RADIOGRAPHY; COMPUTED-TOMOGRAPHY; COST-EFFECTIVENESS; WRIST FRACTURES; SENSITIVITY; SYSTEM; MDCT; MRI;
D O I
10.2214/AJR.19.21478
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to assess the result of adding cone-beam CT to the standard imaging algorithm for patients with suspected radiographically occult traumatic radiocarpal fractures. SUBJECTS AND METHODS. A prospective review was performed on all patients who had cone-beam CT investigation of acute wrist pain after normal initial radiographs. Patients with no identified fractures were clinically reassessed and referred for MRI if concern for a fracture persisted. RESULTS. In all, 117 patients were assessed; 50.4% had fractures identified with a total of 67 radiographically occult fractures. One fracture was identified on MRI that was not seen on cone-beam CT. Cone-beam CT had sensitivity of 98.3% (95% CI, 91.1-100%), specificity of 100% (95% CI, 93.7-100%), positive predictive value of 100%, and negative predictive value of 98.3% (95% CI, 89.1-100%). Accuracy was 99.1% (95% CI, 95.3-100%). CONCLUSION. Incorporating cone-beam CT into routine clinical practice as part of a standardized diagnostic algorithm yielded a 50% fracture detection rate in patients with negative wrist radiographs but ongoing clinical concern for radiocarpal fracture. Cone-beam CT provides more diagnostic information than radiographs at a lower radiation dose than conventional MDCT. Given the poor accuracy of radiographs for acute radiocarpal fractures and the high fracture prevalence in this cohort, we feel that cone-beam CT should be regarded as the new standard of care in the investigation of these patients.
引用
收藏
页码:1117 / 1123
页数:7
相关论文
共 50 条
  • [31] Evaluation of the OSC-TV iterative reconstruction algorithm for cone-beam optical CT
    Matenine, Dmitri
    Mascolo-Fortin, Julia
    Goussard, Yves
    Despres, Philippe
    MEDICAL PHYSICS, 2015, 42 (11) : 6376 - 6386
  • [32] Comparison between cone-beam CT and multidetector-row CT by ROC analysis regarding diagnostic accuracy for artificial alveolar bone defects in the mandibular molar region
    Minami, Seiji
    Ohnishi, Takashi
    Sano, Tomoaki
    Sugiura, Kazutaka
    Nakayama, Eiji
    ORAL RADIOLOGY, 2015, 31 (02) : 97 - 104
  • [33] In vitro evaluation of the accuracy of electronic apex locators and cone-beam CT in the detection of oblique root fractures
    Koc, Simay
    Harorli, Hatice
    Kustarci, Alper
    DENTOMAXILLOFACIAL RADIOLOGY, 2024, 53 (07) : 509 - 514
  • [34] An efficient Monte Carlo-based algorithm for scatter correction in keV cone-beam CT
    Poludniowski, G.
    Evans, P. M.
    Hansen, V. N.
    Webb, S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (12): : 3847 - 3864
  • [35] A hybrid reconstruction algorithm for fast and accurate 4D cone-beam CT imaginga)
    Yan, Hao
    Zhen, Xin
    Folkerts, Michael
    Li, Yongbao
    Pan, Tinsu
    Cervino, Laura
    Jiang, Steve B.
    Jia, Xun
    MEDICAL PHYSICS, 2014, 41 (07)
  • [36] A BPF-FBP tandem algorithm for image reconstruction in reverse helical cone-beam CT
    Cho, Seungryong
    Xia, Dan
    Pellizzari, Charles A.
    Pan, Xiaochuan
    MEDICAL PHYSICS, 2010, 37 (01) : 32 - 39
  • [37] Dual-energy cone-beam CT with a flat-panel detector: Effect of reconstruction algorithm on material classification
    Zbijewski, W.
    Gang, G. J.
    Xu, J.
    Wang, A. S.
    Stayman, J. W.
    Taguchi, K.
    Carrino, J. A.
    Siewerdsen, J. H.
    MEDICAL PHYSICS, 2014, 41 (02)
  • [38] Cone-Beam CT Compared to Multi-Slice CT for the Diagnostic Analysis of Conductive Hearing Loss: A Feasibility Study
    Kemp, Pieter
    Van Stralen, Jiska
    De Graaf, Pim
    Berkhout, Erwin
    Van Horssen, Pepijn
    Merkus, Paul
    JOURNAL OF INTERNATIONAL ADVANCED OTOLOGY, 2020, 16 (02): : 222 - +
  • [39] Diagnostic Performance of Ultrasonography for Evaluation of Osteoarthritis of Ankle Joint Comparison With Radiography, Cone-Beam CT, and Symptoms
    Nevalainen, Mika T.
    Pitkanen, Milla-Maaria
    Saarakkala, Simo
    JOURNAL OF ULTRASOUND IN MEDICINE, 2022, 41 (05) : 1139 - 1146
  • [40] Contrast-Enhanced Cone-Beam Breast CT: An Analysis of Diagnostic Value in Predicting Breast Lesion With Rim Enhancement Malignancy
    Zhao, Xin
    Yang, Jun
    Zuo, Yang
    Kang, Wei
    Liao, Hai
    Zheng, Zhong-Tao
    Su, Dan-Ke
    FRONTIERS IN ONCOLOGY, 2022, 12