Incorporating Cone-Beam CT Into the Diagnostic Algorithm for Suspected Radiocarpal Fractures: A New Standard of Care?

被引:27
|
作者
Gibney, Brian [1 ]
Smith, Michelle [2 ]
Moughty, Adrian [3 ]
Kavanagh, Eoin C. [1 ,4 ]
Hynes, Darragh [2 ,4 ]
MacMahon, Peter J. [1 ,4 ]
机构
[1] Mater Misericordiae Univ Hosp, Dept Radiol, Whitty Bldg,N Circular Rd, Dublin D07 R2WY, Ireland
[2] Mater Misericordiae Univ Hosp, Dept Orthopaed Surg, Dublin, Ireland
[3] Mater Misericordiae Univ Hosp, Emergency Dept, Dublin, Ireland
[4] Univ Coll Dublin, Sch Med, Dublin, Ireland
关键词
cone-beam CT; diagnosis; trauma; wrist; OCCULT SCAPHOID FRACTURES; CONVENTIONAL RADIOGRAPHY; COMPUTED-TOMOGRAPHY; COST-EFFECTIVENESS; WRIST FRACTURES; SENSITIVITY; SYSTEM; MDCT; MRI;
D O I
10.2214/AJR.19.21478
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to assess the result of adding cone-beam CT to the standard imaging algorithm for patients with suspected radiographically occult traumatic radiocarpal fractures. SUBJECTS AND METHODS. A prospective review was performed on all patients who had cone-beam CT investigation of acute wrist pain after normal initial radiographs. Patients with no identified fractures were clinically reassessed and referred for MRI if concern for a fracture persisted. RESULTS. In all, 117 patients were assessed; 50.4% had fractures identified with a total of 67 radiographically occult fractures. One fracture was identified on MRI that was not seen on cone-beam CT. Cone-beam CT had sensitivity of 98.3% (95% CI, 91.1-100%), specificity of 100% (95% CI, 93.7-100%), positive predictive value of 100%, and negative predictive value of 98.3% (95% CI, 89.1-100%). Accuracy was 99.1% (95% CI, 95.3-100%). CONCLUSION. Incorporating cone-beam CT into routine clinical practice as part of a standardized diagnostic algorithm yielded a 50% fracture detection rate in patients with negative wrist radiographs but ongoing clinical concern for radiocarpal fracture. Cone-beam CT provides more diagnostic information than radiographs at a lower radiation dose than conventional MDCT. Given the poor accuracy of radiographs for acute radiocarpal fractures and the high fracture prevalence in this cohort, we feel that cone-beam CT should be regarded as the new standard of care in the investigation of these patients.
引用
收藏
页码:1117 / 1123
页数:7
相关论文
共 50 条
  • [21] The application of cone-beam CT in the aging of bone calluses: a new perspective?
    Cappella, A.
    Amadasi, A.
    Gaudio, D.
    Gibelli, D.
    Borgonovo, S.
    Di Giancamillo, M.
    Cattaneo, C.
    INTERNATIONAL JOURNAL OF LEGAL MEDICINE, 2013, 127 (06) : 1139 - 1144
  • [22] Incorporating the synthetic CT image for improving the performance of deformable image registration between planning CT and cone-beam CT
    Li, Na
    Zhou, Xuanru
    Chen, Shupeng
    Dai, Jingjing
    Wang, Tangsheng
    Zhang, Chulong
    He, Wenfeng
    Xie, Yaoqin
    Liang, Xiaokun
    FRONTIERS IN ONCOLOGY, 2023, 13
  • [23] Diagnostic performance of cone-beam computed tomography for scaphoid fractures: a systematic review and diagnostic meta-analysis
    Yang, Ta-Wei
    Lin, Yen-Yue
    Hsu, Shih-Chang
    Chu, Karen Chia-Wen
    Hsiao, Chih-Wei
    Hsu, Chin-Wang
    Bai, Chyi-Huey
    Chang, Cheng-Kuang
    Hsu, Yuan-Pin
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [24] Improved Diagnostic Accuracy of Ameloblastoma and Odontogenic Keratocyst on Cone-Beam CT by Artificial Intelligence
    Chai, Zi-Kang
    Mao, Liang
    Chen, Hua
    Sun, Ting-Guan
    Shen, Xue-Meng
    Liu, Juan
    Sun, Zhi-Jun
    FRONTIERS IN ONCOLOGY, 2022, 11
  • [25] Cone-beam breast CT using an offset detector: effect of detector offset and image reconstruction algorithm
    Tseng, Hsin Wu
    Karellas, Andrew
    Vedantham, Srinivasan
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (08):
  • [26] Exact radon rebinning algorithm for the long object problem in helical cone-beam CT
    Schaller, S
    Noo, F
    Sauer, F
    Tam, KC
    Lauritsch, G
    Flohr, T
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (05) : 361 - 375
  • [27] Algorithm for x-ray beam hardening and scatter correction in low-dose cone-beam CT: Phantom studies
    Liu, Wenlei
    Rong, Junyan
    Gao, Peng
    Liao, Qimei
    Lu, HongBing
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [28] Translational motion correction algorithm for truncated cone-beam CT using opposite projections
    Gu, Jawook
    Bae, Woong
    Ye, Jong Chul
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2017, 25 (06) : 927 - 944
  • [29] Development of a new three-dimensional image reconstruction algorithm to reduce cone-beam artifacts
    Gomi, T
    Koshida, K
    Miyati, T
    MEDICAL IMAGING 2005: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2005, 5745 : 1046 - 1056
  • [30] Feasibility of improving cone-beam CT number consistency using a scatter correction algorithm
    Li, Jun
    Yao, Weiguang
    Xiao, Ying
    Yu, Yan
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (06): : 167 - 176