Intraoperative Monitoring With Transesophageal Real-Time Three-Dimensional Echocardiography During Transapical Prosthetic Aortic Valve Implantation

被引:14
|
作者
Marcos-Alberca, Pedro [1 ]
Luis Zamorano, Jose [1 ]
Sanchez, Tibisay [1 ]
Maroto, Luis [2 ]
Perez de Isla, Leopoldo [1 ]
Almeria, Carlos [1 ]
Macaya, Carlos [2 ]
Rodriguez, Enrique [2 ]
机构
[1] Univ Complutense, Unidad Imagen Cardiovasc, Serv Cardiol, Inst Cardiovasc,Hosp Clin San Carlos, E-28040 Madrid, Spain
[2] Univ Complutense, Serv Cirugia Cardiaca, Hosp Clin San Carlos, Inst Cardiovasc, E-28040 Madrid, Spain
来源
REVISTA ESPANOLA DE CARDIOLOGIA | 2010年 / 63卷 / 03期
关键词
Prosthetic valve; Echocardiography; Surgery; REPLACEMENT;
D O I
10.1016/S0300-8932(10)70095-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Degenerative aortic stenosis is the most common valvulopathy in Europe. In symptomatic patients, aortic valve replacement with a prosthesis substantially improves prognosis. However, a high percentage of candidates for valve replacement surgery are rejected because of the high risk of serious complications. In recent years, percutaneous and minimally invasive surgical techniques have been developed for the transcatheter implantation of prosthetic aortic valves. These developments could lead to an increase in the number of interventions carried out in high-risk patients as the positive effect of treatment on prognosis would be retained while the complication rate would be reduced. We describe the use of transesophageal echocardiography (TEE) for intratoperative monitoring in 21 patients who underwent transcatheter aortic valve replacement using an transapical approach, and report morphologic findings, hemodynamic results, and complications observed. We propose a standard approach to imaging, in which real-time three-dimensional TEE is used to provide additional information during intratoperative monitoring of transapical transcatheter aortic valve replacement.
引用
收藏
页码:352 / 356
页数:5
相关论文
共 50 条
  • [1] Real-Time Three-Dimensional Transesophageal Echocardiography Adds Value to Transcatheter Aortic Valve Implantation
    Smith, Lindsay A.
    Dworakowski, Rafal
    Bhan, Amit
    Delithanasis, Ioannis
    Hancock, Jane
    MacCarthy, Philip A.
    Wendler, Olaf
    Thomas, Martyn R.
    Monaghan, Mark J.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2013, 26 (04) : 359 - 369
  • [2] Guidance of percutaneous transcatheter aortic valve implantation by real-time three-dimensional transesophageal echocardiography - A single-center experience
    Janosi, Rolf Alexander
    Kahlert, Philipp
    Plicht, Bjoern
    Boese, Dirk
    Wendt, Daniel
    Thielmann, Matthias
    Jakob, Heinz
    Eggebrecht, Holger
    Erbel, Raimund
    Buck, Thomas
    MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 2009, 18 (03) : 142 - 148
  • [3] Application research of three-dimensional transesophageal echocardiography in predicting prosthetic valve size for transcatheter aortic valve implantation
    Meng, Xin
    Sun, Yandan
    Bai, Wei
    Li, Yuxi
    Tuo, Shengjun
    Cao, Liang
    Du, Mengmeng
    Liu, Yang
    Jin, Ping
    Yang, Jian
    Liu, Liwen
    ANNALS OF TRANSLATIONAL MEDICINE, 2022, 10 (02)
  • [4] Comparison of two-dimensional and real-time three-dimensional transesophageal echocardiography in the assessment of aortic valve area
    Furukawa, Atsuko
    Abe, Yukio
    Tanaka, Chiharu
    Ito, Kazato
    Tabuchi, Isao
    Osawa, Kazuhiro
    Kino, Naoto
    Nakagawa, Eiichiro
    Komatsu, Ryushi
    Haze, Kazuo
    Yoshiyama, Minoru
    Yoshikawa, Junichi
    Naruko, Takahiko
    Itoh, Akira
    JOURNAL OF CARDIOLOGY, 2012, 59 (03) : 337 - 343
  • [5] Bioprosthetic tricuspid valve dysfunction evaluated by real-time three-dimensional transesophageal echocardiography
    Sakata K.
    Furuya M.
    Mizuno Y.
    Sato K.
    Minamishima T.
    Takemoto K.
    Taguchi H.
    Soga Y.
    Yoshino H.
    Journal of Echocardiography, 2011, 9 (4) : 158 - 160
  • [6] Role of Intraoperative Real-Time Three-Dimensional Transesophageal Echocardiography During Cone Procedure for Ebstein's Anomaly
    Sujatha, Madassery
    Gadhinglajkar, Shrinivas
    Dharan, Baiju S.
    Sreedhar, Rupa
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2016, 30 (01) : 176 - 178
  • [7] Impact of Three-Dimensional Transesophageal Echocardiography on Prosthesis Sizing for Transcatheter Aortic Valve Implantation
    Husser, Oliver
    Rauch, Simon
    Endemann, Dierk H.
    Resch, Markus
    Nunez, Julio
    Bodi, Vicente
    Hilker, Michael
    Schmid, Christof
    Riegger, Guenter A. J.
    Luchner, Andreas
    Hengstenberg, Christian
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2012, 80 (06) : 956 - 963
  • [8] The value of real-time three-dimensional transesophageal echocardiography in the assessment of paravalvular leak origin following prosthetic mitral valve replacement
    Yildiz, Mustafa
    Duran, Nilufer Eksi
    Gokdeniz, Tayyar
    Kaya, Hasan
    Ozkan, Mehmet
    TURK KARDIYOLOJI DERNEGI ARSIVI-ARCHIVES OF THE TURKISH SOCIETY OF CARDIOLOGY, 2009, 37 (06): : 371 - 377
  • [9] Aortic Root Geometry in Patients with Aortic Stenosis Assessed by Real-Time Three-Dimensional Transesophageal Echocardiography
    Wu, Victor Chien-Chia
    Kaku, Kyoko
    Takeuchi, Masaaki
    Otani, Kyoko
    Yoshitani, Hidetoshi
    Tamura, Masahito
    Abe, Haruhiko
    Lin, Fen-Chiung
    Otsuji, Yutaka
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2014, 27 (01) : 32 - 41
  • [10] Feasibility of transapical aortic valve implantation fully guided by transesophageal echocardiography
    Dumont, Eric
    Lemieux, Jerome
    Doyle, Daniel
    Rodes-Cabau, Josep