Influence of stack geometry on the performance of thermoacoustic refrigerator

被引:12
作者
Nayak, B. Ramesh [1 ]
Pundarika, G. [2 ]
Arya, Bheemsha [3 ]
机构
[1] BMS Coll Engn, Dept Ind Engn & Management, Bengaluru 560019, India
[2] Govt Engn Coll, Ramanagara 562159, India
[3] BMS Coll Engn, Dept Mech Engn, Bengaluru 560019, India
来源
SADHANA-ACADEMY PROCEEDINGS IN ENGINEERING SCIENCES | 2017年 / 42卷 / 02期
关键词
COP; COPR; cooling load; drive ratio; frequency; stack geometry; ENGINES; FLOW;
D O I
10.1007/s12046-016-0585-5
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The work reported in this paper is focused on the performance of a thermoacoustic refrigerator under various operating conditions. The experiments were conducted with various stack geometries fabricated with epoxy glass and Mylar material. Four stacks with different pore sizes are used to evaluate the performance of the refrigerator. Stack 1 has parallel plates of Mylar material 0.12 mm thick spaced 0.36 mm apart. Stacks 2, 3 and 4 are made of epoxy glass with pores of circular cross-section having 1, 2 and 3 mm diameter, respectively. The entire resonator system was constructed from aluminium material coated with polyurethane material from inside to reduce conduction heat losses. Helium gas was used as a working fluid. The experiments were conducted with different drive ratios ranging from 1.6% to 2% with varying cooling load from 2 to 10 W. For the experiments, operating frequencies from 200 to 600 Hz with mean pressure varying from 2 to 10 bar in steps of 2 bar each were considered. The temperatures of the hot end and cold end of the heat exchangers were recorded using RTDs and a data acquisition system under various operating conditions. The coefficient of performance (COP) and relative COP (COPR) are evaluated. Results show that COP of the refrigerator rises with increase of cooling load and decreases at higher drive ratio. It was also observed that the temperature difference between the hot end and cold end of the stack is higher at 2 W cooling load for 400 Hz operating frequency. The temperature difference between the hot end and cold end of the stack was observed to be 19.4, 17.2, 14 and 12.4 degrees C for stacks 1, 2, 3 and 4, respectively, for 10 bar mean pressure and 2 W cooling load. The temperature difference and COP of the parallel plate stack are better compared with other stack geometries.
引用
收藏
页码:223 / 230
页数:8
相关论文
共 21 条
[1]   The impact of gas blockage on the performance of a thermoacoustic refrigerator [J].
Akhavanbazaz, Masoud ;
Siddiqui, M. H. Kamran ;
Bhat, Rama B. .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2007, 32 (01) :231-239
[2]   Acoustic power flow measurement in a thermoacoustic resonator by means of laser Doppler anemometry (LDA) and microphonic measurement [J].
Bailliet, H ;
Lotton, P ;
Bruneau, M ;
Gusev, V ;
Valière, JC ;
Gazengel, B .
APPLIED ACOUSTICS, 2000, 60 (01) :1-11
[3]   Working gases in thermoacoustic engines [J].
Belcher, JR ;
Slaton, WV ;
Raspet, R ;
Bass, HE ;
Lightfoot, J .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1999, 105 (05) :2677-2684
[4]  
Bheemsha Ramesh Nayak B, 2011, INT J EMERGING TREND, V2, P47
[5]  
Emmanuel C.N., 2009, APPL THERM ENG, V29, P2672
[6]   THERMOACOUSTIC REFRIGERATOR FOR SPACE APPLICATIONS [J].
GARRETT, SL ;
ADEFF, JA ;
HOFLER, TJ .
JOURNAL OF THERMOPHYSICS AND HEAT TRANSFER, 1993, 7 (04) :595-599
[7]  
Hofler T.J., 1986, Ph. D. Thesis,
[8]   THERMOACOUSTIC EFFECTS IN A RESONANCE TUBE [J].
MERKLI, P ;
THOMANN, H .
JOURNAL OF FLUID MECHANICS, 1975, 70 (JUL15) :161-177
[9]   TRANSITION TO TURBULENCE IN OSCILLATING PIPE-FLOW [J].
MERKLI, P ;
THOMANN, H .
JOURNAL OF FLUID MECHANICS, 1975, 68 (APR15) :567-&
[10]  
Minner BL, 1997, ASHRAE TRAN, V103, P873