Gas-liquid interfacial area and mass transfer coefficient in a co-current down flow contacting column

被引:6
作者
Dursun, Gulbeyi [1 ]
Akosman, Cevdet [1 ]
机构
[1] Firat Univ, Dept Chem Engn, TR-23279 Elazig, Turkey
关键词
co-current down flow contacting column (CDCC); interfacial area; mass transfer; mass transfer coefficient; fermentation medium;
D O I
10.1002/jctb.1611
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
The gas-liquid interfacial area and mass transfer coefficient for absorption of oxygen from air into water, aqueous glycerol solutions up to 1.5% (w/w) and fermentation medium containing glucose up to a 3% concentration were determined in a co-current down flow contacting column (CDCC; 0.05 m i.d. and 0.8 m length). Experimental studies were conducted using various nozzle diameters at different gas and re-circulation liquid rates. Specific interfacial area (a) is determined from the fractional gas hold-up (80 and the average bubble diameter (db). Once the interfacial area is determined, the volumetric mass transfer coefficient (k(L)a) is then used to evaluate the film mass transfer coefficient in the CDCC. The effects of operating conditions and liquid properties on the specific interfacial area were investigated. The values of interfacial area in air-aqueous glycerol solutions and fermentation media were found to be lower than those in the air-water system. As far as experimental conditions were concerned, the values of interfacial area obtained from this study were found to be considerably higher than those of the literature values of conventional bubble columns. The penetration theory is used to interpret the film mass transfer coefficient and results match the experimental k(L) data reasonably wen. (c) 2006 Society of Chemical Industry
引用
收藏
页码:1859 / 1865
页数:7
相关论文
共 27 条
[21]   Effect of plate geometry on characteristics of fluid flow and mass transfer in external-loop airlift bubble column [J].
Miyahara, T ;
Hamanaka, H ;
Umeda, T ;
Akagi, Y .
JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 1999, 32 (05) :689-695
[22]  
Özer A, 2000, J CHEM TECHNOL BIOT, V75, P1061, DOI 10.1002/1097-4660(200011)75:11<1061::AID-JCTB318>3.0.CO
[23]  
2-K
[24]  
RAO NVR, 1988, CAN J CHEM ENG, V66, P211
[25]   GAS HOLDUP IN 2-PHASE AND 3-PHASE DOWNFLOW BUBBLE-COLUMNS [J].
SHAH, YT ;
KULKARNI, AA ;
WIELAND, JH ;
CARR, NL .
CHEMICAL ENGINEERING JOURNAL AND THE BIOCHEMICAL ENGINEERING JOURNAL, 1983, 26 (02) :95-104
[26]   Comparison of experimental methods for determination of the volumetric mass transfer coefficient in fermentation processes [J].
Tobajas, M ;
García-Calvo, E .
HEAT AND MASS TRANSFER, 2000, 36 (03) :201-207
[27]   Effect of contaminants on mass transfer coefficients in bubble column and airlift contactors [J].
Vasconcelos, JMT ;
Rodrigues, JML ;
Orvalho, SCP ;
Alves, SS ;
Mendes, RL ;
Reis, A .
CHEMICAL ENGINEERING SCIENCE, 2003, 58 (08) :1431-1440