The Functional Aortic Annulus in the 3D Era: Focus on Transcatheter Aortic Valve Replacement for the Perioperative Echocardiographer

被引:18
|
作者
Patel, Prakash A. [1 ]
Gutsche, Jacob T. [1 ]
Vernick, William J. [1 ]
Giri, Jay S. [2 ]
Ghadimi, Kamrouz [1 ]
Weiss, Stuart J. [1 ]
Jagasia, Dinesh H. [2 ]
Bavaria, Joseph E. [3 ]
Augoustides, John G. T. [1 ]
机构
[1] Univ Penn, Perelman Sch Med, Dept Anesthesiol & Crit Care, Cardiovasc & Thorac Sect, Philadelphia, PA 19104 USA
[2] Univ Penn, Philadelphia, PA 19104 USA
[3] Univ Penn, Perelman Sch Med, Dept Med, Thorac Aort Program,Div Cardiovasc Med, Philadelphia, PA 19104 USA
关键词
functional aortic annulus; hinge points; virtual ring; aortic leaflets; ellipse; transcatheter aortic valve replacement; paravalvular leak; multidetector computed axial tomography; three-dimensional transesophageal echocardiography; Valve Academic Research Consortium; aortic annular area; coronary artery height; 3-DIMENSIONAL TRANSESOPHAGEAL ECHOCARDIOGRAPHY; COMPUTED-TOMOGRAPHY; PARAVALVULAR REGURGITATION; CONSENSUS DOCUMENT; IMPLANTATION; ROOT; PREDICTORS; ACCURACY; REPAIR; MULTICENTER;
D O I
10.1053/j.jvca.2014.05.027
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The functional aortic annulus represents a sound clinical framework for understanding the components of the aortic root complex. Recent three-dimensional imaging analysis has demonstrated that the aortic annulus frequently is elliptical rather than circular. Comprehensive three-dimensional quantification of this aortic annular geometry by transesophageal echocardiography and/or multidetector computed tomography is essential to guide precise prosthesis sizing in transcatheter aortic valve replacement to minimize paravalvular leak for optimal clinical outcome. Furthermore, three-dimensional transesophageal echocardiography accurately can quantify additional parameters of the functional aortic annulus such as coronary height for complete sizing profiles for all valve types in transcatheter aortic valve replacement. Although it is maturing rapidly as a clinical imaging modality, its role in transcatheter aortic valve replacement is seen best as complementary to multidetector computed tomography in a multidisciplinary heart team model. (C) 2014 Published by Elsevier Inc.
引用
收藏
页码:240 / 245
页数:6
相关论文
共 50 条
  • [41] Balloon Versus Computed Tomography Sizing of the Aortic Annulus for Transcatheter Aortic Valve Replacement and the Impact of Left Ventricular Outflow Tract Calcification and Morphology on Sizing
    Condado, Jose F.
    Lerakis, Stamatios
    Stewart, James
    Jensen, Hanna
    Henry, Travis S.
    Ko, Sung Min
    Stillman, Arthur
    Rajaei, Mohammad H.
    Mavromatis, Kreton
    Devireddy, Chandan
    Sarin, Eric
    Leshnower, Brad
    Guyton, Robert
    Kaebnick, Brian
    Thourani, Vinod H.
    Block, Peter C.
    Babaliaros, Vasilis
    JOURNAL OF INVASIVE CARDIOLOGY, 2016, 28 (07) : 295 - 304
  • [42] Automated 3D Analysis of Multislice Computed Tomography to Define the Line of Perpendicularity of the Aortic Annulus and of the Implanted Valve: Benefit on Planning Transcatheter Aortic Valve Replacement
    Samin, Mariam
    Juthier, Francis
    Van Belle, Camille
    Agostoni, Pierfrancesco
    Kluin, Jolanda
    Stella, Pieter R.
    Ramjankhan, Faiez
    Budde, Ricardo P. J.
    Sieswerda, Gertjan
    Algeri, Emanuela
    Elkalioubie, Ahmed
    Belkacemi, Anouar
    Bertrand, Michel E.
    Doevendans, Pieter A.
    Van Belle, Eric
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2014, 83 (01) : E119 - E127
  • [43] Aborted sternotomy in the modern era of transcatheter aortic valve replacement
    Gasparovic, Ivo
    Artemiou, Panagiotis
    Hulman, Michal
    COR ET VASA, 2020, 62 (01) : 33 - 36
  • [44] Transcatheter aortic valve replacement: perioperative stroke and beyond
    Mokin, Maxim
    Zivadinov, Robert
    Dwyer, Michael G.
    Lazar, Ronald M.
    Hopkins, L. Nelson
    Siddiqui, Adnan H.
    EXPERT REVIEW OF NEUROTHERAPEUTICS, 2017, 17 (04) : 327 - 334
  • [45] Computed Tomography for Planning Transcatheter Aortic Valve Replacement
    Apfaltrer, Paul
    Henzler, Thomas
    Blanke, Phillip
    Krazinski, Aleksander W.
    Silverman, Justin R.
    Schoepf, U. Joseph
    JOURNAL OF THORACIC IMAGING, 2013, 28 (04) : 231 - 239
  • [46] Valve-in-Valve Transcatheter Aortic Valve Replacement Versus Redo Surgical Aortic Valve Replacement An Updated Meta-Analysis
    Sa, Michel Pompeu B. O.
    Van den Eynde, Jef
    Simonato, Matheus
    Cavalcanti, Luiz Rafael P.
    Doulamis, Ilias P.
    Weixler, Viktoria
    Kampaktsis, Polydoros N.
    Gallo, Michele
    Laforgia, Pietro L.
    Zhigalov, Konstantin
    Ruhparwar, Arjang
    Weymann, Alexander
    Pibarot, Philippe
    Clavel, Marie-Annick
    JACC-CARDIOVASCULAR INTERVENTIONS, 2021, 14 (02) : 211 - 220
  • [47] Lifetime Management of Patients With Severe Aortic Stenosis in the Era of Transcatheter Aortic Valve Replacement
    Jubran, Ayman
    Patel, Raumil, V
    Sathananthan, Janarthanan
    Wijeysundera, Harindra C.
    CANADIAN JOURNAL OF CARDIOLOGY, 2024, 40 (02) : 210 - 217
  • [48] Pacemaker dependency after transcatheter aortic valve replacement compared to surgical aortic valve replacement
    Hwang, You Mi
    Kim, Jun
    Nam, Gi Byoung
    Choi, Kee Joon
    Park, Duk-Woo
    Kang, Do-Yoon
    Park, Seung-Jung
    Park, Seo Young
    MEDICINE, 2021, 100 (22) : E26123
  • [49] Successful Transcatheter Aortic Valve Replacement for Bicuspid Aortic Valve
    Maeda, Koichi
    Kuratani, Toru
    Torikai, Kei
    Shimamura, Kazuo
    Ueno, Takayoshi
    Toda, Koichi
    Sawa, Yoshiki
    ANNALS OF THORACIC AND CARDIOVASCULAR SURGERY, 2014, 20 : 705 - 708
  • [50] Transcatheter aortic valve replacement in bicuspid aortic valve disease
    Kochman, Janusz
    Rymuza, Bartosz
    Huczek, Zenon
    CURRENT OPINION IN CARDIOLOGY, 2015, 30 (06) : 594 - 602