Haemodynamic determinants of the mitral valve closure sound: a finite element study

被引:35
作者
Einstein, DR [1 ]
Kunzelman, KS
Reinhall, PG
Nicosia, MA
Cochran, RP
机构
[1] Univ Washington, Dept Bioengn, Seattle, WA USA
[2] Central Maine Heart & Vasc Inst, Ctr Maine Med Ctr, Lewiston, ME USA
[3] Univ Washington, Dept Mech Engn, Seattle, WA USA
[4] Univ Minnesota, Dept Biomed Engn, Minneapolis, MN USA
关键词
fluid-structure interaction; microstructure; acoustics; LS-DYNA; validation;
D O I
10.1007/BF02345218
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Automatic acoustic classification and diagnosis of mitral valve. disease remain outstanding biomedical problems. Although considerable attention has been given to the evolution of signal processing techniques, the mechanics of the first heart sound generation has been largely overlooked. In this study, the haemodynamic determinants of the first heart sound were examined in a computational model. Specifically, the relationship of the transvalvular pressure and its maximum derivative to the time-frequency content of the acoustic pressure was examined. To model the transient vibrations of the mitral valve apparatus bathed in a blood medium, a dynamic, non-linear, fluid-coupled finite element model of the mitral valve leaflets and chordae tendinae was constructed. It was found that the root mean squared (RMS), acoustic pressure varied linearly (r(2) = 0.99) from 0.010 to 0.259 mmHg, following an increase in maximum dP/dt from 415 to 12470 mm Hg s(-1). Over that same range, peak frequency varied non-linearly from 59.6 to 88.1 Hz. An increase in left-ventricular pressure at coaptation from 22.5 to 58.5 mm Hg resulted in a linear (r(2) = 0.91) rise in RMS acoustic pressure from 0.017 to 1.41 mmHg. This rise in transmitral pressure was accompanied by a non-linear rise in peak frequency from 63.5 to 74.1 Hz. The relationship between the transvalvular pressure and its derivative and the time-frequency content of the first heart sound has been examined comprehensively in a computational model for the first time. Results suggest that classification schemes should embed both of these variables for more accurate classification.
引用
收藏
页码:832 / 846
页数:15
相关论文
共 51 条
[1]  
AUBERT AE, 1984, J CARDIOGR, V14, P159
[2]  
BARRY DT, 1991, 14 ANN INT C IEEE EN
[3]   Time-frequency and time-scale techniques for the classification of native and bioprosthetic heart valve sounds [J].
Bentley, PM ;
Grant, PM ;
McDonnell, JTE .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1998, 45 (01) :125-128
[4]   ONE-DIMENSIONAL MODEL OF DIASTOLIC SEMILUNAR VALVE VIBRATIONS PRODUCTIVE OF HEART SOUNDS [J].
BLICK, EF ;
SABBAH, HN ;
STEIN, PD .
JOURNAL OF BIOMECHANICS, 1979, 12 (03) :223-227
[5]   Lack of allelic association between 102T/C polymorphism of serotonin receptor type 2A gene and schizophrenia in Chinese [J].
Chen, CH ;
Lee, YR ;
Wei, FC ;
Koong, FJ ;
Hwu, HG ;
Hsiao, KJ .
PSYCHIATRIC GENETICS, 1997, 7 (01) :35-38
[6]   Time-frequency analysis of the first heart sound: Part 3: Application to dogs with varying cardiac contractility and to patients with mitral mechanical prosthetic heart valves [J].
Chen, D ;
Durand, LG ;
Lee, HC ;
Wieting, DW .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1997, 35 (05) :455-461
[7]   Time-frequency analysis of the first heart sound. Part 2: An appropriate time-frequency representation technique [J].
Chen, D ;
Durand, LG ;
Guo, Z ;
Lee, HC .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1997, 35 (04) :311-317
[8]  
Cochran R P, 1991, ASAIO Trans, V37, pM447
[9]  
Dagum P, 2000, CIRCULATION, V102, P62
[10]  
Decoodt P, 1990, Int J Card Imaging, V6, P47, DOI 10.1007/BF01798432