Quantitative Assessment of Weight-Bearing Fracture Biomechanics Using Extremity Cone-Beam CT

被引:3
作者
Liu, S. Z. [1 ]
Cao, Q. [1 ]
Osgood, G. M. [2 ]
Siewerdsen, J. H. [1 ,3 ]
Stayman, J. W. [1 ]
Zbijewski, W. [1 ]
机构
[1] Johns Hopkins Univ, Dept Biomed Engn, Baltimore, MD 21205 USA
[2] Johns Hopkins Univ Hosp, Dept Orthoped Surg, Baltimore, MD 21205 USA
[3] Johns Hopkins Univ Hosp, Russell H Morgan Dept Radiol, Baltimore, MD 21205 USA
来源
MEDICAL IMAGING 2020: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING | 2021年 / 11317卷
关键词
orthopedic imaging; quantitative imaging; fracture biomechanics; surgical hardware; 3D-2D registration; deformable registration; REGISTRATION; PLACEMENT; MODEL;
D O I
10.1117/12.2549768
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose: We investigate an application of multisource extremity Cone-Beam CT (CBCT) with capability of weight-bearing tomographic imaging to obtain quantitative measurements of load-induced deformation of metal internal fixation hardware (e.g. tibial plate). Such measurements are desirable to improve the detection of delayed fusion or non-union of fractures, potentially facilitating earlier return to weight-bearing activities. Methods: To measure the deformation, we perform a deformable 3D-2D registration of a prior model of the implant to its CBCT projections under load-bearing. This Known-Component Registration (KC-Reg) framework avoids potential errors that emerge when the deformation is estimated directly from 3D reconstructions with metal artifacts. The 3D-2D registration involves a free-form deformable (FFD) point cloud model of the implant and a 3D cubic B-spline representation of the deformation. Gradient correlation is used as the optimization metric for the registration. The proposed approach was tested in experimental studies on the extremity CBCT system. A custom jig was designed to apply controlled axial loads to a fracture model, emulating weight-bearing imaging scenarios. Performance evaluation involved a Sawbone tibia phantom with an -4 mm fracture gap. The model was fixed with a locking plate and imaged under five loading conditions. To investigate performance in the presence of confounding background gradients, additional experiments were performed with a pre-deformed femoral plate placed in a water bath with Ca bone mineral density inserts. Errors were measured using eight reference BBs for the tibial plate, and surface point distances for the femoral plate, where a prior model of deformed implant was available for comparison. Results: Both in the loaded tibial plate case and for the femoral plate with confounding background gradients, the proposed KC-Reg framework estimated implant deformations with errors of <0.2 mm for the majority of the investigated deformation magnitudes (error range 0.14 - 0.25 mm). The accuracy was comparable between 3D-2D registrations performed from 12 x-ray views and registrations obtained from as few as 3 views. This was likely enabled by the unique three-source x-ray unit on the extremity CBCT scanner, which implements two off-central-plane focal spots that provided oblique views of the field-of-view to aid implant pose estimation. Conclusion: Accurate measurements of fracture hardware deformations under physiological weight-bearing are feasible using an extremity CBCT scanner and FFD 3D-2D registration. The resulting deformed implant models can be incorporated into tomographic reconstructions to reduce metal artifacts and improve quantification of the mineral content of fracture callus in CBCT volumes.
引用
收藏
页数:8
相关论文
共 41 条
  • [31] 4D cone-beam CT reconstruction using multi-organ meshes for sliding motion modeling
    Zhong, Zichun
    Gu, Xuejun
    Mao, Weihua
    Wang, Jing
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (03) : 996 - 1020
  • [32] Feasability of a Frameless Brain Biopsy System for Companion Animals Using Cone-Beam CT-Based Automated Registration
    Meneses, Felix
    Maiolini, Arianna
    Forterre, Franck
    Oevermann, Anna
    Schweizer-Gorgas, Daniela
    FRONTIERS IN VETERINARY SCIENCE, 2022, 8
  • [33] COMPARISON OF PLANNED VERSUS ACTUAL DOSE DELIVERED FOR EXTERNAL BEAM ACCELERATED PARTIAL BREAST IRRADIATION USING CONE-BEAM CT AND DEFORMABLE REGISTRATION
    Hasan, Yasmin
    Kim, Leonard
    Wloch, Jennifer
    Chi, Y.
    Liang, J.
    Martinez, Alvaro
    Yan, Di
    Vicini, Frank
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 80 (05): : 1473 - 1476
  • [34] Digital reconstruction of high-quality daily 4D cone-beam CT images using prior knowledge of anatomy and respiratory motion
    Zhang, Yongbin
    Yang, Jinzhong
    Zhang, Lifei
    Court, Laurence E.
    Gao, Song
    Balter, Peter A.
    Dong, Lei
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2015, 40 : 30 - 38
  • [35] Pre- and postoperative assessment of sinus grafting procedures using cone-beam computed tomography compared with panoramic radiographs
    Baciut, Mihaela
    Hedesiu, Mihaela
    Bran, Simion
    Jacobs, Reinhilde
    Nackaerts, Olivia
    Baciut, Grigore
    CLINICAL ORAL IMPLANTS RESEARCH, 2013, 24 (05) : 512 - 516
  • [36] Image-guided pedicle screws using intraoperative cone-beam CT and navigation. A cost-effectiveness study
    Lee, Yu Chao
    Lee, Robert
    JOURNAL OF CLINICAL NEUROSCIENCE, 2020, 72 : 68 - 71
  • [37] Image-based scatter correction for cone-beam CT using flip swin transformer U-shape network
    Zhang, Xueren
    Jiang, Yangkang
    Luo, Chen
    Li, Dengwang
    Niu, Tianye
    Yu, Gang
    MEDICAL PHYSICS, 2023, 50 (08) : 5002 - 5019
  • [38] An alternative method to match planned and achieved positions of implants, after virtual planning using cone-beam CT data and surgical guide templates - A method reducing patient radiation exposure (part I)
    Nickenig, Hans-Joachim
    Eitner, Stephan
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2010, 38 (06) : 436 - 440
  • [39] Response Assessment in Locally Advanced Head and Neck Cancer Based on RECIST and Volume Measurements Using Cone Beam CT Images
    Hou, Jidong
    Guerrero, Mariana
    Suntharalingam, Mohan
    D'Souza, Warren D.
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2015, 14 (01) : 19 - 27
  • [40] Assessment of In Vivo Lumbar Inter-Vertebral Motion: Reliability of a Novel Dynamic Weight-Bearing Magnetic Resonance Imaging Technique Using a Side-Bending Task
    Mahato, Niladri Kumar
    Montuelle, Stephane
    Clark, Brian C.
    ASIAN SPINE JOURNAL, 2019, 13 (03) : 377 - 385