Quantitative Assessment of Weight-Bearing Fracture Biomechanics Using Extremity Cone-Beam CT

被引:3
作者
Liu, S. Z. [1 ]
Cao, Q. [1 ]
Osgood, G. M. [2 ]
Siewerdsen, J. H. [1 ,3 ]
Stayman, J. W. [1 ]
Zbijewski, W. [1 ]
机构
[1] Johns Hopkins Univ, Dept Biomed Engn, Baltimore, MD 21205 USA
[2] Johns Hopkins Univ Hosp, Dept Orthoped Surg, Baltimore, MD 21205 USA
[3] Johns Hopkins Univ Hosp, Russell H Morgan Dept Radiol, Baltimore, MD 21205 USA
来源
MEDICAL IMAGING 2020: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING | 2021年 / 11317卷
关键词
orthopedic imaging; quantitative imaging; fracture biomechanics; surgical hardware; 3D-2D registration; deformable registration; REGISTRATION; PLACEMENT; MODEL;
D O I
10.1117/12.2549768
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose: We investigate an application of multisource extremity Cone-Beam CT (CBCT) with capability of weight-bearing tomographic imaging to obtain quantitative measurements of load-induced deformation of metal internal fixation hardware (e.g. tibial plate). Such measurements are desirable to improve the detection of delayed fusion or non-union of fractures, potentially facilitating earlier return to weight-bearing activities. Methods: To measure the deformation, we perform a deformable 3D-2D registration of a prior model of the implant to its CBCT projections under load-bearing. This Known-Component Registration (KC-Reg) framework avoids potential errors that emerge when the deformation is estimated directly from 3D reconstructions with metal artifacts. The 3D-2D registration involves a free-form deformable (FFD) point cloud model of the implant and a 3D cubic B-spline representation of the deformation. Gradient correlation is used as the optimization metric for the registration. The proposed approach was tested in experimental studies on the extremity CBCT system. A custom jig was designed to apply controlled axial loads to a fracture model, emulating weight-bearing imaging scenarios. Performance evaluation involved a Sawbone tibia phantom with an -4 mm fracture gap. The model was fixed with a locking plate and imaged under five loading conditions. To investigate performance in the presence of confounding background gradients, additional experiments were performed with a pre-deformed femoral plate placed in a water bath with Ca bone mineral density inserts. Errors were measured using eight reference BBs for the tibial plate, and surface point distances for the femoral plate, where a prior model of deformed implant was available for comparison. Results: Both in the loaded tibial plate case and for the femoral plate with confounding background gradients, the proposed KC-Reg framework estimated implant deformations with errors of <0.2 mm for the majority of the investigated deformation magnitudes (error range 0.14 - 0.25 mm). The accuracy was comparable between 3D-2D registrations performed from 12 x-ray views and registrations obtained from as few as 3 views. This was likely enabled by the unique three-source x-ray unit on the extremity CBCT scanner, which implements two off-central-plane focal spots that provided oblique views of the field-of-view to aid implant pose estimation. Conclusion: Accurate measurements of fracture hardware deformations under physiological weight-bearing are feasible using an extremity CBCT scanner and FFD 3D-2D registration. The resulting deformed implant models can be incorporated into tomographic reconstructions to reduce metal artifacts and improve quantification of the mineral content of fracture callus in CBCT volumes.
引用
收藏
页数:8
相关论文
共 41 条
  • [1] Marker-free motion correction in weight-bearing cone-beam CT of the knee joint
    Berger, M.
    Mueller, K.
    Aichert, A.
    Unberath, M.
    Thies, J.
    Choi, J. -H.
    Fahrig, R.
    Maier, A.
    MEDICAL PHYSICS, 2016, 43 (03) : 1235 - 1248
  • [2] Quantitative Evaluation of Bone Microstructure using High-Resolution Extremity Cone-Beam CT with a CMOS Detector
    Subramanian, S.
    Brehler, M.
    Cao, Q.
    Gonzalez, F. J. Quevedo
    Breighner, R. E.
    Canino, J. A.
    Wright, T.
    Yorkston, J.
    Siewerdsen, J. H.
    Zbijewski, W.
    MEDICAL IMAGING 2019: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2019, 10953
  • [3] Weight-bearing cone-beam CT with extensive coverage for volumetric imaging in adolescent idiopathic scoliosis: system implementation and initial validation
    Liang, Zejun
    Xia, Chunchao
    Wang, Qian
    Chen, Zengtong
    Zhang, Yu
    Ye, Chao
    Zhang, Yiteng
    Yang, Jie
    Wang, Hairong
    Zheng, Han
    Du, Jing
    Li, Zhenlin
    Tang, Jing
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2023, 46 (04) : 1467 - 1474
  • [4] The Role of Cone-Beam Computed Tomography CT Extremity Arthrography in the Preoperative Assessment of Osteoarthritis
    Hamard, Marion
    Sans Merce, Marta
    Gorican, Karel
    Poletti, Pierre-Alexandre
    Neroladaki, Angeliki
    Boudabbous, Sana
    TOMOGRAPHY, 2023, 9 (06) : 2134 - 2147
  • [5] Motion compensation in extremity cone-beam CT using a penalized image sharpness criterion
    Sisniega, A.
    Stayman, J. W.
    Yorkston, J.
    Siewerdsen, J. H.
    Zbijewski, W.
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (09) : 3712 - 3734
  • [6] Quantitative cone-beam CT imaging in radiation therapy using planning CT as a prior: First patient studies
    Niu, Tianye
    Al-Basheer, Ahmad
    Zhu, Lei
    MEDICAL PHYSICS, 2012, 39 (04) : 1991 - 2000
  • [7] METAL ARTIFACT REDUCTION IN CONE-BEAM EXTREMITY IMAGES USING GATED CONVOLUTIONS
    Agrawal, Harshit
    Hietanen, Ari
    Sarkka, Simo
    2021 IEEE 18TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2021, : 1087 - 1090
  • [8] Cone-Beam CT Images as an Indicator of QACT During Adaptive Proton Therapy of Extremity Sarcomas
    Biswal, Nrusingh C.
    Zhang, Baoshe
    Nichols, Elizabeth
    Witek, Matthew E.
    Regine, William F.
    Yi, Byongyong
    INTERNATIONAL JOURNAL OF PARTICLE THERAPY, 2024, 12
  • [9] Motion compensation for cone-beam CT using Fourier consistency conditions
    Berger, M.
    Xia, Y.
    Aichinger, W.
    Mentl, K.
    Unberath, M.
    Aichert, A.
    Riess, C.
    Hornegger, J.
    Fahrig, R.
    Maier, A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (17) : 7181 - 7215
  • [10] Improving Image Quality of Cone-Beam CT Using Alternating Regression Forest
    Lei, Yang
    Tang, Xiangyang
    Higgins, Kristin
    Wang, Tonghe
    Liu, Tian
    Dhabaan, Anees
    Shim, Hyunsuk
    Curran, Walter J.
    Yang, Xiaofeng
    MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573