Three-dimensional T1ρ-weighted MRI at 1.5 Tesla

被引:49
|
作者
Borthakur, A [1 ]
Wheaton, A [1 ]
Charagundla, SR [1 ]
Shapiro, EM [1 ]
Regatte, RR [1 ]
Akella, SVS [1 ]
Kneeland, JB [1 ]
Reddy, R [1 ]
机构
[1] Univ Penn, Dept Radiol, Stellar Chance Labs B1, Philadelphia, PA 19104 USA
关键词
T1; rho; cartilage; spin-lock; RF heating; SAR;
D O I
10.1002/jmri.10296
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To design and implement a magnetic resonance imaging (MRI) pulse sequence capable of performing three-dimensional T-1rho-weighted MRI on a 1.5-T clinical scanner, and determine the optimal sequence parameters, both theoretically and experimentally, so that the energy deposition by the radiofrequency pulses in the sequence, measured as the specific absorption rate (SAR), does not exceed safety guidelines for imaging human subjects. Materials and Methods: A three-pulse cluster was pre-encoded to a three-dimensional gradient-echo imaging sequence to create a three-dimensional, T-1rho-weighted MRI pulse sequence. Imaging experiments were performed on a GE clinical scanner with a custom-built knee-coil. We validated the performance of this sequence by imaging articular cartilage of a bovine patella and comparing T-1rho values measured by this sequence to those obtained with a previously tested two-dimensional imaging sequence. Using a previously developed model for SAR calculation, the imaging parameters were adjusted such that the energy deposition by the radiofrequency pulses in the sequence did not exceed safety guidelines for imaging human subjects. The actual temperature increase due to the sequence was measured in a phantom by a MRI-based temperature mapping technique. Following these experiments, the performance of this sequence was demonstrated in vivo by obtaining T-1rho-weighted images of the knee joint of a healthy individual. Results: Calculated T-1rho of articular cartilage in the specimen was similar for both and three-dimensional and two-dimensional methods (84+/-2 msec and 80+/-3 msec, respectively). The temperature increase in the phantom resulting from the sequence was 0.015degreesC, which is well below the established safety guidelines. Images of the human knee joint in vivo demonstrate a clear delineation of cartilage from surrounding tissues. Conclusion: We developed and implemented a three-dimensional T-1rho-weighted pulse sequence on a 1.5-T clinical scanner.
引用
收藏
页码:730 / 736
页数:7
相关论文
共 50 条
  • [21] Three-Dimensional Bioprinted MR-Trackable Regenerative Scaffold for Postimplantation Monitoring on T1-Weighted MRI
    Loai, Sadi
    Szulc, Daniel A.
    Cheng, Hai-Ling Margaret
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2022, 56 (02) : 570 - 578
  • [22] Three-dimensional T1 mapping for dGEMRIC at 3.0 T using the look locker method
    Kimelman, T
    Vu, A
    Storey, P
    McKenzie, C
    Burstein, D
    Prasad, P
    INVESTIGATIVE RADIOLOGY, 2006, 41 (02) : 198 - 203
  • [23] Parallel-transmission-enabled three-dimensional T2-weighted imaging of the human brain at 7 Tesla
    Massire, Aurelien
    Vignaud, Alexandre
    Robert, Benjamin
    Le Bihan, Denis
    Boulant, Nicolas
    Amadon, Alexis
    MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (06) : 2195 - 2203
  • [24] Three-dimensional delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) at 1.5T and 3.0T
    McKenzie, Charles A.
    Williams, Ashley
    Prasad, Pottumarthi V.
    Burstein, Deborah
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 24 (04) : 928 - 933
  • [25] Imaging of the Wrist at 1.5 Tesla Using Isotropic Three-Dimensional Fast Spin Echo Cube
    Stevens, Kathryn J.
    Wallace, Charles G.
    Chen, Weitian
    Rosenberg, Jarrett K.
    Gold, Garry E.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 33 (04) : 908 - 915
  • [26] The development of a three-dimensional T1 image calculation program in proportion to the DICOM data of any marketing clinical MRI systems
    Ikehira, H
    Watanabe, A
    Obata, T
    Tsujii, H
    Jones, KM
    Li, S
    Moriya, H
    MAGNETIC RESONANCE IMAGING, 2004, 22 (04) : 595 - 597
  • [27] REGIONAL VARIATIONS IN MYOCARDIAL T1 RELAXATION TIMES IN HEALTHY ADULTS AT 1.5 AND 3.0 TESLA
    Rauhalammi, S.
    Carrick, D.
    Mangion, K.
    Clerfond, G.
    Barrientos, P. Hall
    McComb, C.
    Radjenovic, A.
    Berry, C.
    HEART, 2015, 101 : A15 - A15
  • [28] Geometric accuracy in three-dimensional coordinates of Leksell stereotactic skull frame with wide-bore 1.5-T MRI compared with conventional 1.5-T MRI
    Nakazawa, Hisato
    Komori, Masataka
    Shibamoto, Yuta
    Takikawa, Yukinori
    Mori, Yoshimasa
    Tsugawa, Takahiko
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2014, 58 (05) : 595 - 600
  • [29] Free-Breathing Post-Contrast Three-Dimensional T1 Mapping: Volumetric Assessment of Myocardial T1 Values
    Weingaertner, Sebastian
    Akcakaya, Mehmet
    Roujol, Sebastien
    Basha, Tamer
    Stehning, Christian
    Kissinger, Kraig V.
    Goddu, Beth
    Berg, Sophie
    Manning, Warren J.
    Nezafat, Reza
    MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (01) : 214 - 222
  • [30] High-resolution three-dimensional ANGIE T1 mapping of the whole heart
    Bhairav B Mehta
    Michael Salerno
    Frederick H Epstein
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)