Three-dimensional T1ρ-weighted MRI at 1.5 Tesla

被引:49
作者
Borthakur, A [1 ]
Wheaton, A [1 ]
Charagundla, SR [1 ]
Shapiro, EM [1 ]
Regatte, RR [1 ]
Akella, SVS [1 ]
Kneeland, JB [1 ]
Reddy, R [1 ]
机构
[1] Univ Penn, Dept Radiol, Stellar Chance Labs B1, Philadelphia, PA 19104 USA
关键词
T1; rho; cartilage; spin-lock; RF heating; SAR;
D O I
10.1002/jmri.10296
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To design and implement a magnetic resonance imaging (MRI) pulse sequence capable of performing three-dimensional T-1rho-weighted MRI on a 1.5-T clinical scanner, and determine the optimal sequence parameters, both theoretically and experimentally, so that the energy deposition by the radiofrequency pulses in the sequence, measured as the specific absorption rate (SAR), does not exceed safety guidelines for imaging human subjects. Materials and Methods: A three-pulse cluster was pre-encoded to a three-dimensional gradient-echo imaging sequence to create a three-dimensional, T-1rho-weighted MRI pulse sequence. Imaging experiments were performed on a GE clinical scanner with a custom-built knee-coil. We validated the performance of this sequence by imaging articular cartilage of a bovine patella and comparing T-1rho values measured by this sequence to those obtained with a previously tested two-dimensional imaging sequence. Using a previously developed model for SAR calculation, the imaging parameters were adjusted such that the energy deposition by the radiofrequency pulses in the sequence did not exceed safety guidelines for imaging human subjects. The actual temperature increase due to the sequence was measured in a phantom by a MRI-based temperature mapping technique. Following these experiments, the performance of this sequence was demonstrated in vivo by obtaining T-1rho-weighted images of the knee joint of a healthy individual. Results: Calculated T-1rho of articular cartilage in the specimen was similar for both and three-dimensional and two-dimensional methods (84+/-2 msec and 80+/-3 msec, respectively). The temperature increase in the phantom resulting from the sequence was 0.015degreesC, which is well below the established safety guidelines. Images of the human knee joint in vivo demonstrate a clear delineation of cartilage from surrounding tissues. Conclusion: We developed and implemented a three-dimensional T-1rho-weighted pulse sequence on a 1.5-T clinical scanner.
引用
收藏
页码:730 / 736
页数:7
相关论文
共 37 条
[31]   Fast MRI of RF heating via phase difference mapping [J].
Shapiro, EM ;
Borthakur, A ;
Shapiro, MJ ;
Reddy, R ;
Leigh, JS .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (03) :492-498
[32]   SUPERFICIAL-TISSUE AND DEEP-TISSUE TEMPERATURE INCREASES IN ANESTHETIZED DOGS DURING EXPOSURE TO HIGH SPECIFIC ABSORPTION RATES IN A 1.5-T MR IMAGER [J].
SHUMAN, WP ;
HAYNOR, DR ;
GUY, AW ;
WESBEY, GE ;
SCHAEFER, DJ ;
MOSS, AA .
RADIOLOGY, 1988, 167 (02) :551-554
[33]  
TAILOR DR, 2001, P 9 ANN M ISMRM GLAS
[34]  
*US FDA, 1998, GUID SUBM PREM NOT
[35]  
VANDELOO AAJ, 1994, AGENTS ACTIONS, V41, P200
[36]   T1p MR imaging characteristics of human anterior tibial and gastrocnemius muscles [J].
Virta, A ;
Komu, M ;
Lundbom, N ;
Kormano, M .
ACADEMIC RADIOLOGY, 1998, 5 (02) :104-110
[37]   FURTHER OBSERVATIONS ON THE MEASUREMENT OF TISSUE T-1 TO MONITOR TEMPERATURE IN-VIVO BY MRI [J].
YOUNG, IR ;
HAND, JW ;
OATRIDGE, A ;
PRIOR, MV ;
FORSE, GR .
MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (03) :342-345