Study of Gafchromic® EBT film response over a large dose range

被引:26
作者
Martisikova, Maria [1 ]
Jaekel, Oliver [1 ,2 ]
机构
[1] German Canc Res Ctr, Dept Med Phys Radiat Oncol, D-69120 Heidelberg, Germany
[2] Univ Klinikum Heidelberg, Heidelberger Ionenstrahl Therapiezentrum HIT, D-69120 Heidelberg, Germany
关键词
DOSIMETRY; MODEL;
D O I
10.1088/0031-9155/55/10/N03
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Presently Gafchromic EBT films are widely used for relative dose verification in standard radiation therapy using high-energy photons, inclusive IMRT. The use of films for dosimetry in medical ion beams is more complicated due to the strongly inhomogeneous dose deposition by ions on microscopic level. Track structuremodels, presently used to describe dosimeter response as a function of the ion field properties, are based on input information which can be obtained from the film response in photon beams. We therefore studied the performance of Gafchromic EBT films, ancestors of currently available EBT2 films, in Co-60 photon beams. The dose-response curve was measured from 7.5 x 10(-2) Gy to 3 x 10(4) Gy. The dynamic range, linearity and dose rate dependence of this calibration curve were studied. A high saturation dose of 3 x 10(3) Gy, and thus a large dynamic range, was observed. No signs of supralinearity and bleaching due to radiation were found. No dependence of the response on the dose rate at high dose rates and high doses was found. All those properties justify the use of simplified models of the film response to ions. Furthermore, fits of the calibration data by predictions of different models for signal creation mechanism of dosimetric materials were performed. The best description was found for the recently published gamma-distributed single-hit model which takes into account different sizes of the active centres.
引用
收藏
页码:N281 / N290
页数:10
相关论文
共 19 条
[1]  
B_tter-Jensen L., 2003, Optically Stimulated Luminescence Dosimetry, V1st
[2]   Absorption spectra variations of EBT radiochromic film from radiation exposure [J].
Butson, MJ ;
Cheung, T ;
Yu, PKN .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (13) :N135-N140
[3]   THEORY OF RBE FOR HEAVY ION BOMBARDMENT OF DRY ENZYMES AND VIRUSES [J].
BUTTS, JJ ;
KATZ, R .
RADIATION RESEARCH, 1967, 30 (04) :855-&
[4]   From the limits of the classical model of sensitometric curves to a realistic model based on the percolation theory for GafChromic™ EBT films [J].
del Moral, F. ;
Vazquez, J. A. ;
Ferrero, J. J. ;
Willisch, P. ;
Ramirez, R. D. ;
Teijeiro, A. ;
Lopez Medina, A. ;
Andrade, B. ;
Vazquez, J. ;
Salvador, F. ;
Medal, D. ;
Salgado, M. ;
Munoz, V. .
MEDICAL PHYSICS, 2009, 36 (09) :4015-4026
[5]  
DERTINGER H, 1969, MOLEKULARE STRAHLENB, P13
[6]   Precise radiochromic film dosimetry using a flat-bed document scanner [J].
Devic, S ;
Seuntjens, J ;
Sham, E ;
Podgorsak, EB ;
Schmidtlein, CR ;
Kirov, AS ;
Soares, CG .
MEDICAL PHYSICS, 2005, 32 (07) :2245-2253
[7]   Clinical use of EBT model Gafchromic™ film in radiotherapy [J].
Fiandra, Christian ;
Ricardi, Umberto ;
Ragona, Riccardo ;
Anglesio, Silvia ;
Giglioli, Francesca Romana ;
Calamia, Elisa ;
Lucio, Francesco .
MEDICAL PHYSICS, 2006, 33 (11) :4314-4319
[8]   EXPERIMENTAL AND CALCULATED RESPONSE OF A RADIOCHROMIC DYE FILM DOSIMETER TO HIGH-LET RADIATIONS [J].
HANSEN, JW ;
OLSEN, KJ .
RADIATION RESEARCH, 1984, 97 (01) :1-15
[9]  
HELTHANSEN J, 2009, COMMUNICATION
[10]  
*INT SPEC PROD, 2006, GAFCHR EBT SELF DEV