Measurement of dead time by time interval distribution method

被引:16
|
作者
Arkani, Mohammad [1 ]
Raisali, Gholamreza [2 ]
机构
[1] NSTRI, Reactor Res Sch, Tehran, Iran
[2] NSTRI, Radiat Applicat Res Sch, Tehran, Iran
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 2015年 / 774卷
关键词
Dead time; Nuclear radiation detector; Poisson process; Time interval distribution; POISSON; STATISTICS;
D O I
10.1016/j.nima.2014.11.069
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Non-random event losses due to dead time effect in nuclear radiation detection systems distort the original Poisson process info a new type of distribution. As the characteristics of the distribution depend on physical properties of the detection system, it is possible to estimate the dead time parameters based on time interval analysis, this is the problem investigated in this work. A BF3 ionization chamber is taken as a case study to check the validity of the method in experiment. The results are compared with the data estimated by power rising experiment performed in Esfahan Heavy Water Zero Power Reactor (EHWZPR). Using Monte Carlo simulation, the problem is elaborately studied and useful range for counting rates of the detector is determined. The proposed method is accurate and applicable for all kinds of radiation detectors with no potential difficulty and no need for any especial nuclear facility. This is not a time consuming method and advanced capability of online examination during normal operation of the detection system is possible. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:151 / 158
页数:8
相关论文
共 50 条
  • [31] PRECISE MEASUREMENT OF DEAD-TIME
    SCHONFELD, E
    JANSSEN, H
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 339 (1-2): : 137 - 143
  • [32] DEAD TIME MEASUREMENT OF GM COUNTERS
    FAVA, L
    SANGIUST, V
    NUCLEAR INSTRUMENTS & METHODS, 1966, 42 (02): : 325 - &
  • [33] Dead time losses and their measurement in DIRAC
    Kulikov, A
    Zhabitsky, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 527 (03): : 591 - 597
  • [34] RECIPROCAL TIME-INTERVAL MEASUREMENT
    KAY, RH
    JOURNAL OF PHYSIOLOGY-LONDON, 1965, 181 (02): : P12 - &
  • [35] Time Interval Measurement in the Picosecond Accuracy
    Hamza, Gihan G.
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2019, 62 (06) : 778 - 784
  • [36] Time Interval Measurement in the Picosecond Accuracy
    Gihan G. Hamza
    Instruments and Experimental Techniques, 2019, 62 : 778 - 784
  • [37] MEASUREMENT OF PARTICLE-VELOCITY USING A TIME INTERVAL DISTRIBUTION OF PHOTOELECTRIC PULSES
    FUJII, KI
    SUZUKI, N
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1983, 22 (04): : 719 - 722
  • [38] A Multi-Channel time interval measurement for Time Comparison
    Shi Shao-hua
    Li Xiao-hui
    Zhang Hui-jun
    Zhao Zhi-xiong
    2011 JOINT CONFERENCE OF THE IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM/EUROPEAN FREQUENCY AND TIME FORUM PROCEEDINGS, 2011, : 529 - 531
  • [39] Dead-time measurement for radiation counters by variance-to-mean method
    Hashimoto, K
    Ohya, K
    Yamane, Y
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 1996, 33 (11) : 863 - 868
  • [40] Super-High Resolution Time Interval Measurement Method Based on Time-Space Relationships
    Du Bao-Qiang
    Zhou Wei
    CHINESE PHYSICS LETTERS, 2009, 26 (10)