Why is flow-mediated dilation dependent on arterial size? Assessment of the shear stimulus using phase-contrast magnetic resonance imaging

被引:80
作者
Silber, HA
Ouyang, P
Bluemke, DA
Gupta, SN
Foo, TK
Lima, JAC
机构
[1] Johns Hopkins Univ, Sch Med, Div Cardiol, Baltimore, MD USA
[2] Johns Hopkins Univ, Sch Med, Dept Radiol, Baltimore, MD 21205 USA
[3] GE Co, Med Syst, Appl Sci Lab, Baltimore, MD USA
来源
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY | 2005年 / 288卷 / 02期
关键词
endothelial function; vasodilation; blood flow;
D O I
10.1152/ajpheart.00612.2004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Flow-mediated dilation (FMD) is strongly dependent on arterial size, but the reasons for this phenomenon are poorly understood. We have previously shown that FMD is greater in small brachial arteries because the shear stress stimulus is greater in small brachial arteries. However, it is unclear why the shear stimulus is greater in small arteries. Furthermore, this relationship has not been investigated in other, differently sized arterial beds. Postischemic systolic shear stress and resulting FMD were evaluated in the brachial and femoral arteries of 24 young, healthy adults using phase-contrast magnetic resonance imaging. Arterial shear and radius were calculated from the velocity profile via a best-fit parabola before and after occlusion. Summing the velocity pixels provided hyperemic systolic flow. FMD was proportional to hyperemic shear in the brachial and femoral arteries ( P < 0.0001, r = 0.60). Hyperemic systolic flow was proportional to radius(2) ( P < 0.0001, r = 0.93). Applying this relationship to the Poiseuille equation ( shear is proportional to flow/radius(3)) shows that hyperemic shear is proportional to radius(2)/radius(3) and, therefore, explains why hyperemic shear is proportional to 1/radius. We conclude that FMD is proportional to hyperemic systolic shear stress in both the brachial and the femoral arteries. The hyperemic shear stimulus for FMD is greater in small arteries due to the dependence of postischemic systolic flow on radius squared. Therefore, greater FMD in small arteries does not necessarily reflect better conduit artery endothelial function. Evaluating the shear stimulus using phase-contrast magnetic resonance imaging enhances the understanding of mechanisms underlying FMD.
引用
收藏
页码:H822 / H828
页数:7
相关论文
共 38 条
  • [1] Comparison of ultrasound assessment of flow-mediated dilatation in the radial and brachial artery with upper and forearm cuff positions
    Agewall, S
    Doughty, RN
    Bagg, W
    Whalley, GA
    Braatvedt, G
    Sharpe, N
    [J]. CLINICAL PHYSIOLOGY, 2001, 21 (01): : 9 - 14
  • [2] Determination of femoral artery endothelial function by phase contrast magnetic resonance imaging
    Alexander, MR
    Kitzman, DW
    Khaliq, S
    Darty, SN
    Hamilton, CA
    Herrington, DM
    Link, KM
    Hundley, WG
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2001, 88 (09) : 1070 - +
  • [3] FLOW-MEDIATED AND REFLEX CHANGES IN LARGE PERIPHERAL ARTERY TONE IN HUMANS
    ANDERSON, EA
    MARK, AL
    [J]. CIRCULATION, 1989, 79 (01) : 93 - 100
  • [4] Coronary artery flow velocity is related to lumen area and regional left ventricular mass
    Anderson, HV
    Stokes, MJ
    Leon, M
    Abu-Halawa, SA
    Stuart, Y
    Kirkeeide, RL
    [J]. CIRCULATION, 2000, 102 (01) : 48 - 54
  • [5] Occlusion cuff position is an important determinant of the time course and magnitude of human brachial artery flow-mediated dilation
    Berry, KL
    Skyrme-Jones, RAP
    Meredith, IT
    [J]. CLINICAL SCIENCE, 2000, 99 (04) : 261 - 267
  • [6] Bland M., 2000, INTRO MED STAT
  • [7] A NONINVASIVE METHOD TO ESTIMATE WALL SHEAR RATE USING ULTRASOUND
    BRANDS, PJ
    HOEKS, APG
    HOFSTRA, L
    RENEMAN, RS
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1995, 21 (02) : 171 - 185
  • [8] Pulsatile stretch and shear stress: Physical stimuli determining the production of endothelium-derived relaxing factors
    Busse, R
    Fleming, I
    [J]. JOURNAL OF VASCULAR RESEARCH, 1998, 35 (02) : 73 - 84
  • [9] CIGARETTE-SMOKING IS ASSOCIATED WITH DOSE-RELATED AND POTENTIALLY REVERSIBLE IMPAIRMENT OF ENDOTHELIUM-DEPENDENT DILATION IN HEALTHY-YOUNG ADULTS
    CELERMAJER, DS
    SORENSEN, KE
    GEORGAKOPOULOS, D
    BULL, C
    THOMAS, O
    ROBINSON, J
    DEANFIELD, JE
    [J]. CIRCULATION, 1993, 88 (05) : 2149 - 2155
  • [10] NONINVASIVE DETECTION OF ENDOTHELIAL DYSFUNCTION IN CHILDREN AND ADULTS AT RISK OF ATHEROSCLEROSIS
    CELERMAJER, DS
    SORENSEN, KE
    GOOCH, VM
    SPIEGELHALTER, DJ
    MILLER, OI
    SULLIVAN, ID
    LLOYD, JK
    DEANFIELD, JE
    [J]. LANCET, 1992, 340 (8828) : 1111 - 1115