Test cell analysis of the use of a supply air window as a passive solar component

被引:36
作者
Baker, PH
McEvoy, M
机构
[1] Univ Westminster, Dept Architecture, London NW1 5LS, England
[2] BRE Ltd, Scottish Lab, Glasgow G75 0RZ, Lanark, Scotland
关键词
Heat transfer - Mathematical models - Ventilation;
D O I
10.1016/S0038-092X(00)00048-7
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A series of experiments was conducted to determine the performance characteristic of a 'double' window used to pre-heat background room ventilation. A theoretical model of heat exchange conditions within the window was compared with results from a test cell. The test cell was used in different modes, firstly free-ventilated with the service room window and interconnecting duet to the cell left open, and then with forced ventilation at a consistent velocity to analyse the relative extent of direct solar and ventilation heat gain. A subsidiary study sought to determine the frequency of positive and negative air Row through trickle vents under real house conditions, this was compared with glass temperatures from the test cell measurements to assess the risk of condensation forming within the window. By reference to recent work on ventilated PV systems it was possible to derive a method of relating the U value and Solar Heat Gain Coefficient within the window cavity to a range of boundary conditions. (C) 2000 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:113 / 130
页数:18
相关论文
共 8 条
  • [1] BAKER P, 1997, C1 PIT, P9
  • [2] BAKER P, 1992, PASSYS 2 FINAL REPOR
  • [3] DEMEESTER J, 1997, DRAFT JOULE PV HYBRI
  • [4] FAIST A, 1977, P 1 INT C SOL BUILD, P308
  • [5] ORESZCYN T, 1993, P 3 EUR C ARCH 17 21, P522
  • [6] WRIGHT JL, 1986, P SOL EN SOC CAN WIN, P219
  • [7] YANNAS S, 1994, SOLAR ENERGY HOUSING, V1, P3
  • [8] ADV GLAZING SYSTEM L