摘要
In vivo C-13 magnetic resonance spectroscopy (MRS) is a unique and effective tool for studying dynamic human brain metabolism and the cycling of neurotransmitters. One of the major technical challenges for in vivo C-13-MRS is the high radio frequency (RF) power necessary for heteronuclear decoupling. In the common practice of in vivo C-13-MRS, alkanyl carbons are detected in the spectra range of 10-65 ppm. The amplitude of decoupling pulses has to be significantly greater than the large one-bond H-1-C-13 scalar coupling ((1)J(CH) = 125-145Hz). Two main proton decoupling methods have been developed: broadband stochastic decoupling and coherent composite or adiabatic pulse decoupling (e.g., WALTZ); the latter is widely used because of its efficiency and superb performance under inhomogeneous B1 field. Because the RF power required for proton decoupling increases quadratically with field strength, in vivo C-13-MRS using coherent decoupling is often limited to lowmagnetic fields [<=4 Tesla (T)] to keep the local and averaged specific absorption rate (SAR) under the safety guidelines established by the International Electrotechnical Commission (IEC) and the US Food and Drug Administration (FDA). Alternately, carboxylic/amide carbons are coupled to protons via weak long-range H-1-C-13 scalar couplings, which can be decoupled using low RF power broadband stochastic decoupling. Recently, the carboxylic/amide C-13-MRS technique using low power random RF heteronuclear decoupling was safely applied to human brain studies at 7T. Here, we review the two major decoupling methods and the carboxylic/amide C-13-MRS with low power decoupling strategy. Further decreases in RF power deposition by frequency-domain windowing and time-domain random under-sampling are also discussed. Low RF power decoupling opens the possibility of performing in vivo C-13 experiments of human brain at very high magnetic fields (such as 11.7T), where signal-to-noise ratio as well as spatial and temporal spectral resolution are more favorable than lower fields.
引用
收藏
页数:16
相关论文
共 43 条
  • [1] A half-volume coil for efficient proton decoupling in humans at 4 Tesla
    Adriany, G
    Gruetter, R
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1997, 125 (01) : 178 - 184
  • [2] Barker PB, 2001, MAGNET RESON MED, V45, P226, DOI 10.1002/1522-2594(200102)45:2<226::AID-MRM1031>3.0.CO
  • [3] 2-Z
  • [4] In vivo quantitation of cerebral metabolite concentrations using natural abundance 13C MRS at 1.5 T
    Blüm, S
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1999, 136 (02) : 219 - 225
  • [5] Novel peak assignments of in vivo 13C MRS in human brain at 1.5 T
    Blüml, S
    Hwang, JH
    Moreno, A
    Ross, BD
    [J]. JOURNAL OF MAGNETIC RESONANCE, 2000, 143 (02) : 292 - 298
  • [6] PROTON-DECOUPLED, OVERHAUSER-ENHANCED, SPATIALLY LOCALIZED C-13 SPECTROSCOPY IN HUMANS
    BOTTOMLEY, PA
    HARDY, CJ
    ROEMER, PB
    MUELLER, OM
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1989, 12 (03) : 348 - 363
  • [7] The Contribution of Blood Lactate to Brain Energy Metabolism in Humans Measured by Dynamic 13C Nuclear Magnetic Resonance Spectroscopy
    Boumezbeur, Fawzi
    Petersen, Kitt F.
    Cline, Gary W.
    Mason, Graeme F.
    Behar, Kevin L.
    Shulman, Gerald I.
    Rothman, Douglas L.
    [J]. JOURNAL OF NEUROSCIENCE, 2010, 30 (42) : 13983 - 13991
  • [8] Bracewell Ronald N., 2000, The Fourier Transform and Its Applications
  • [9] Robust uncertainty principles:: Exact signal reconstruction from highly incomplete frequency information
    Candès, EJ
    Romberg, J
    Tao, T
    [J]. IEEE TRANSACTIONS ON INFORMATION THEORY, 2006, 52 (02) : 489 - 509
  • [10] Measurement of human tricarboxylic acid cycle rates during visual activation by 13C magnetic resonance spectroscopy
    Chhina, N
    Kuestermann, E
    Halliday, J
    Simpson, LJ
    Macdonald, IA
    Bachelard, HS
    Morris, PG
    [J]. JOURNAL OF NEUROSCIENCE RESEARCH, 2001, 66 (05) : 737 - 746