Estimates of the image quality in accordance with radiation dose for pediatric imaging using deep learning CT: A phantom study

被引:3
|
作者
Jeon, Pil-Hyun [1 ]
Kim, Daehong [2 ]
Chung, Myung-Ae [3 ]
机构
[1] Yonsei Univ, Dept Radiol, Woju Severance Christian Hosp, Wonju, South Korea
[2] Eulji Univ, Dept Radiol Sci, Seongnam, South Korea
[3] Eulji Univ, Dept Bigdata Med Convergence, Seongnam, South Korea
来源
2022 IEEE INTERNATIONAL CONFERENCE ON BIG DATA AND SMART COMPUTING (IEEE BIGCOMP 2022) | 2022年
关键词
Deep learning reconstruction (DLR); Pediatric computed tomography (CT); Image quality; Radiation dose; ABDOMINAL CT; ALGORITHM;
D O I
10.1109/BigComp54360.2022.00078
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Pediatric patients are at higher risk of radiation-induced damage than adults because cells of children tend to be sensitive to radiation. Therefore, the purpose of this study is to evaluated the dose reduction and image quality in pediatric computed tomography (CT) using deep learning reconstruction (DLR). Pediatric and adult phantom images were acquired with various tube voltages (kV), radiation doses, and image reconstruction methods. Tube voltages of 80, 100, and 120 kV were used to evaluate the image quality such as contrast-to-noise ratio (CNR). Radiation dose was set based on volume CT dose index (CTDIvol) and did not exceed the diagnostic reference level for abdominal CT scans in children and adults. To confirm the noise reduction effect of DLR, images acquired with DLR were compared with filtered back projection (FBP) and iterative reconstruction (IR) images. In the results on the effect of tube voltage, a 100 kV improved the CNR in both pediatric and adult phantom images of DLR. In the results according to the effect of the image reconstruction method, DLR showed almost superior results in terms of image quality than FBP and IR at the CTDIvol. Under the same imaging conditions, the CNR of pediatric phantom images was higher than that of adult phantom images. According to the results, DLR can improve image quality by reducing noise during abdominal CT scans in children. In addition, since the same image quality can be maintained even at a lower dose than adult CT scans, DLR will be useful for CT scans in children.
引用
收藏
页码:352 / 356
页数:5
相关论文
共 50 条
  • [1] Effect of Tube Voltage and Radiation Dose on Image Quality in Pediatric Abdominal CT Using Deep Learning Reconstruction: A Phantom Study
    Kim, Daehong
    Jeon, Pil-Hyun
    Lee, Chang-Lae
    Chung, Myung-Ae
    SYMMETRY-BASEL, 2023, 15 (02):
  • [2] Improving Image Quality and Reducing Radiation Dose for Pediatric CT by Using Deep Learning Reconstruction
    Brady, Samuel L.
    Trout, Andrew T.
    Somasundaram, Elanchezhian
    Anton, Christopher G.
    Li, Yinan
    Dillman, Jonathan R.
    RADIOLOGY, 2021, 298 (01) : 180 - 188
  • [3] Image quality and dose reduction opportunity of deep learning image reconstruction algorithm for CT: a phantom study
    Greffier, Joel
    Hamard, Aymeric
    Pereira, Fabricio
    Barrau, Corinne
    Pasquier, Hugo
    Beregi, Jean Paul
    Frandon, Julien
    EUROPEAN RADIOLOGY, 2020, 30 (07) : 3951 - 3959
  • [4] Image quality and dose reduction opportunity of deep learning image reconstruction algorithm for CT: a phantom study
    Joël Greffier
    Aymeric Hamard
    Fabricio Pereira
    Corinne Barrau
    Hugo Pasquier
    Jean Paul Beregi
    Julien Frandon
    European Radiology, 2020, 30 : 3951 - 3959
  • [5] Estimates of the image quality and the radiation dose for head and abdomen phantom image acquisition by using dual-energy CT
    Dae-Hong Kim
    Hee-Joung Kim
    Chang-Lae Lee
    Pil-Hyun Jeon
    Won-Hyung Lee
    Sung-Soo Jeon
    Journal of the Korean Physical Society, 2012, 60 : 1150 - 1156
  • [6] Estimates of the Image Quality and the Radiation Dose for Head and Abdomen Phantom Image Acquisition by Using Dual-energy CT
    Kim, Dae-Hong
    Kim, Hee-Joung
    Lee, Chang-Lae
    Jeon, Pil-Hyun
    Lee, Won-Hyung
    Jeon, Sung-Soo
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2012, 60 (07) : 1150 - 1156
  • [7] Evaluation of radiation dose and image quality of CT scan for whole-body pediatric PET/CT: A phantom study
    Yang, Ching-Ching
    Liu, Shu-Hsin
    Mok, Greta S. P.
    Wu, Tung-Hsin
    MEDICAL PHYSICS, 2014, 41 (09)
  • [8] Deep learning image reconstruction algorithm for abdominal multidetector CT at different tube voltages: assessment of image quality and radiation dose in a phantom study
    Hye Joo Park
    Seo-Youn Choi
    Ji Eun Lee
    Sanghyeok Lim
    Min Hee Lee
    Boem Ha Yi
    Jang Gyu Cha
    Ji Hye Min
    Bora Lee
    Yunsub Jung
    European Radiology, 2022, 32 : 3974 - 3984
  • [9] Deep learning image reconstruction algorithm for abdominal multidetector CT at different tube voltages: assessment of image quality and radiation dose in a phantom study
    Park, Hye Joo
    Choi, Seo-Youn
    Lee, Ji Eun
    Lim, Sanghyeok
    Lee, Min Hee
    Yi, Boem Ha
    Cha, Jang Gyu
    Min, Ji Hye
    Lee, Bora
    Jung, Yunsub
    EUROPEAN RADIOLOGY, 2022, 32 (06) : 3974 - 3984
  • [10] Improving the image quality of pediatric chest CT angiography with low radiation dose and contrast volume using deep learning image reconstruction
    Sun, Jihang
    Li, Haoyan
    Li, Jianying
    Yu, Tong
    Li, Michelle
    Zhou, Zuofu
    Peng, Yun
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2021, 11 (07) : 3051 - 3058