Safety With Echocardiographic Contrast Agents

被引:88
作者
Muskula, Preetham R. [1 ]
Main, Michael L. [1 ]
机构
[1] St Lukes Mid Amer Heart Inst, 4330 Wornall Rd,Suite 2000, Kansas City, MO 64111 USA
关键词
contrast media; echocardiography; stress; product labeling; pulmonary heart disease; ULTRASOUND CONTRAST; STRESS ECHOCARDIOGRAPHY; HOSPITALIZED-PATIENTS; ACUTE MORTALITY; ALBUMIN MICROBUBBLES; VENTRICULAR-FUNCTION; DIAGNOSTIC-ACCURACY; IMAGE-ENHANCEMENT; SYSTOLIC PRESSURE; EJECTION FRACTION;
D O I
10.1161/CIRCIMAGING.116.005459
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In October 2007, the Food and Drug Administration mandated significant revisions to product labeling for the commercially available echocardiographic contrast agents (ECA) Definity and Optison after spontaneous healthcare provider reports of 4 patient deaths and approximate to 190 severe cardiopulmonary reactions occurring in close temporal relationship to ECA administration. Since then, multiple large ECA safety studies have been published and have included outpatients, hospitalized patients (including the critically ill), patients undergoing stress echocardiography, and patients with pulmonary hypertension. In addition, the Food and Drug Administration has convened 2 Advisory Committee meetings and the product labels for Optison and Definity have been substantially revised with a softening of safety restrictions. In this review, we will address the safety of ECA use in patients with serious cardiopulmonary conditions, patients with intracardiac shunts, and special patient populations including pulmonary hypertension, pediatrics, and pregnancy. In addition, we will discuss the confounding role of pseudocomplication in attribution of adverse events during diagnostic testing, the current status of the ECA Black Box Warning, and recommended safety precautions during ECA administration.
引用
收藏
页数:9
相关论文
共 64 条
[1]   Safety of Contrast Agent Use During Stress Echocardiography in Patients With Elevated Right Ventricular Systolic Pressure A Cohort Study [J].
Abdelmoneim, Sahar S. ;
Bernier, Mathieu ;
Scott, Christopher G. ;
Dhoble, Abhijeet ;
Ness, Sue Ann C. ;
Hagen, Mary E. ;
Moir, Stuart ;
McCully, Robert B. ;
Pellikka, Patricia A. ;
Mulvagh, Sharon L. .
CIRCULATION-CARDIOVASCULAR IMAGING, 2010, 3 (03) :240-248
[2]   Safety of Contrast Agent Use During Stress Echocardiography A 4-Year Experience From a Single-Center Cohort Study of 26,774 Patients [J].
Abdelmoneim, Sahar S. ;
Bernier, Mathieu ;
Scott, Christopher G. ;
Dhoble, Abhijeet ;
Ness, Sue Ann C. ;
Hagen, Mary E. ;
Moir, Stuart ;
McCully, Robert B. ;
Pellikka, Patricia A. ;
Mulvagh, Sharon L. .
JACC-CARDIOVASCULAR IMAGING, 2009, 2 (09) :1048-1056
[3]   Safety of myocardial flash-contrast echocardiography in combination with dobutamine stress testing for the detection of ischaemia in 5250 studies [J].
Aggeli, C. ;
Giannopoulos, G. ;
Roussakis, G. ;
Christoforatou, E. ;
Marinos, G. ;
Toli, C. ;
Pitsavos, C. ;
Stefanadis, C. .
HEART, 2008, 94 (12) :1571-1577
[4]   Safety of Contrast in Stress Echocardiography in Stable Patients and in Patients With Suspected Acute Coronary Syndrome but Negative 12-Hour Troponin [J].
Anantharam, Brijesh ;
Chahal, Navtej ;
Chelliah, Rajesh ;
Ramzy, Ihab ;
Gani, Firoz ;
Senior, Roxy .
AMERICAN JOURNAL OF CARDIOLOGY, 2009, 104 (01) :14-18
[5]   Overview of the 2008 Food and Drug Administration Advisory Committee on Safety Considerations in the Development of Ultrasound Contrast Agents [J].
Asch, Federico M. ;
Weissman, Neil J. .
CIRCULATION, 2009, 119 (14) :1956-1961
[6]   Safety and Feasibility of Contrast Echocardiography for ECMO Evaluation [J].
Bennett, Courtney E. ;
Tweet, Marysia S. ;
Michelena, Hector I. ;
Schears, Gregory J. ;
Mulvagh, Sharon L. .
JACC-CARDIOVASCULAR IMAGING, 2017, 10 (05) :603-604
[7]   TRANS-PULMONARY PASSAGE OF VENOUS AIR EMBOLI [J].
BUTLER, BD ;
HILLS, BA .
JOURNAL OF APPLIED PHYSIOLOGY, 1985, 59 (02) :543-547
[8]   Improved left ventricular endocardial border delineation and opacification with OPTISON (FS069), a new echocardiographic contrast agent - Results of a phase III multicenter trial [J].
Cohen, JL ;
Cheirif, J ;
Segar, DS ;
Gillam, LD ;
Gottdiener, JS ;
Hausnerova, E ;
Bruns, DE .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (03) :746-752
[9]   Safety of contrast-enhanced ultrasound in children for non-cardiac applications: a review by the Society for Pediatric Radiology (SPR) and the International Contrast Ultrasound Society (ICUS) [J].
Darge, Kassa ;
Papadopoulou, Frederica ;
Ntoulia, Aikaterini ;
Bulas, Dorothy I. ;
Coley, Brian D. ;
Fordham, Lynn A. ;
Paltiel, Harriet J. ;
McCarville, Beth ;
Volberg, Frank M. ;
Cosgrove, David O. ;
Goldberg, Barry B. ;
Wilson, Stephanie R. ;
Feinstein, Steven B. .
PEDIATRIC RADIOLOGY, 2013, 43 (09) :1063-1073
[10]   Safety and Efficacy of Commercially Available Ultrasound Contrast Agents for Rest and Stress Echocardiography A Multicenter Experience [J].
Dolan, Melda S. ;
Gala, Simil S. ;
Dodla, Saritha ;
Abdelmoneim, Sahar S. ;
Xie, Feng ;
Cloutier, David ;
Bierig, Michelle ;
Mulvagh, Sharon L. ;
Porter, Thomas R. ;
Labovitz, Arthur J. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (01) :32-38