Evaluation of a Modified Stejs']jskal-Tanner Diffusion Encoding Scheme, Permitting a Marked Reduction in TE, in Diffusion-Weighted Imaging of Stroke Patients at 3 T

被引:37
作者
Morelli, John N. [1 ]
Runge, Val M. [1 ]
Feiweier, Thorsten [2 ]
Kirsch, John E. [2 ]
Williams, Kenneth W. [1 ]
Attenberger, Ulrike I. [3 ]
机构
[1] Texas A&M Univ Hlth Sci Ctr, Dept Radiol, Scott & White Clin & Hosp, Temple, TX USA
[2] Siemens AG, Healthcare Sector, D-8520 Erlangen, Germany
[3] Heidelberg Univ, Dept Clin Radiol & Nucl Med, Univ Med Ctr Mannheim, D-6800 Mannheim, Germany
关键词
diffusion weighted imaging; magnetic susceptibility; spatial distortion; MRI; brain infarction; IMAGES; ECHO; PROPELLER; MRI; ISCHEMIA; GRADIENT; NOISE; TESLA; EPI;
D O I
10.1097/RLI.0b013e3181c65c11
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate a modified Stejskal-Tanner diffusion gradient pulsing scheme that applies diffusion encoding during the entire time between the 2 requisite radiofrequency pulses, shortening TE. Materials and Methods: Seventeen healthy volunteers and 15 patients with acute and early subacute infarcts were evaluated at 3 T utilizing: a conventional bipolar gradient double spin echo planar imaging diffusion weighted imaging with a parallel imaging factor of 2 (p2) and a modified Stejskal-Tanner short TE (sTE) SE echo planar imaging diffusion weighted imaging with parallel imaging factors of 2, 3, and 4. Signal-to-noise ratio (SNR) and susceptibility-induced spatial distortions were quantified, and a blinded reader ranked scans in terms of susceptibility artifact and overall preference. Results: The sTE sequence allowed a shortening in TE of 18 to 28 milliseconds versus the standard bipolar gradient sequence. SNRs were generally not significantly different among the sTE scans because of compensation by number of scan averages. By using twice the number of averages, the SNR with the bipolar gradient sequence was not significantly different from that of the sTE sequences in patients. sTE scans with higher parallel imaging factors demonstrated less susceptibility-related artifact. The blinded reader ranked the p3 or p4 sTE scans most preferred and the bipolar gradient scans least or tied for least preferred in every case. Conclusions: Utilization of the sTE modified Stejskal-Tanner sequence markedly improves SNR-an increase that may be used with parallel imaging to improve overall scan quality whereas maintaining reasonable scan times and SNR.
引用
收藏
页码:29 / 35
页数:7
相关论文
共 25 条
[1]   Elimination of eddy current artifacts in diffusion-weighted echo-planar images: The use of bipolar gradients [J].
Alexander, AL ;
Tsuruda, JS ;
Parker, DL .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (06) :1016-1021
[2]   Diffusion Weighted Imaging A Comprehensive Evaluation of a Fast Spin Echo DWI Sequence With BLADE (PROPELLER) k-Space Sampling at 3 T, Using a 32-Channel Head Coil in Acute Brain Ischemia [J].
Attenberger, Ulrike I. ;
Runge, Val M. ;
Stemmer, Alto ;
Williams, Kenneth D. ;
Naul, L. Gill ;
Michaely, Henrik J. ;
Schoenberg, Stefan O. ;
Reiser, Maximilian F. ;
Wintersperger, Bernd J. .
INVESTIGATIVE RADIOLOGY, 2009, 44 (10) :656-661
[3]   Improved diffusion-weighted single-shot echo-planar imaging (EPI) in stroke using Sensitivity Encoding (SENSE) [J].
Bammer, R ;
Keeling, SL ;
Augustin, M ;
Pruessmann, KP ;
Wolf, R ;
Stollberger, R ;
Hartung, HP ;
Fazekas, F .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (03) :548-554
[4]   Eddy current correction in diffusion-weighted imaging using pairs of images acquired with opposite diffusion gradient polarity [J].
Bodammer, N ;
Kaufmann, J ;
Kanowski, M ;
Tempelmann, C .
MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (01) :188-193
[5]   A TECHNIQUE FOR ACCURATE MAGNETIC-RESONANCE-IMAGING IN THE PRESENCE OF FIELD INHOMOGENEITIES [J].
CHANG, H ;
FITZPATRICK, JM .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1992, 11 (03) :319-329
[6]   Multishot diffusion-weighted PROPELLER magnetic resonance imaging of the abdomen [J].
Deng, Jie ;
Miller, Frank H. ;
Salem, Riad ;
Omary, Reed A. ;
Larson, Andrew C. .
INVESTIGATIVE RADIOLOGY, 2006, 41 (10) :769-775
[7]   Multishot Targeted PROPELLER Magnetic Resonance Imaging Description of the Technique and Initial Applications [J].
Deng, Jie ;
Larson, Andrew C. .
INVESTIGATIVE RADIOLOGY, 2009, 44 (08) :454-462
[8]  
Engelter ST, 2008, SWISS MED WKLY, V138, P729, DOI 2008/49/smw-12249
[9]   Eddy-Current Compensated Diffusion Weighting with a Single Refocusing RF Pulse [J].
Finsterbusch, Juergen .
MAGNETIC RESONANCE IN MEDICINE, 2009, 61 (03) :748-754
[10]   Diffusion-Weighted Imaging in Patients With Acute Brain Ischemia at 3 T Current Possibilities and Future Perspectives Comparing Conventional Echoplanar Diffusion-Weighted Imaging and Fast Spin Echo Diffusion-Weighted Imaging Sequences Using BLADE (PROPELLER) [J].
Fries, Peter ;
Runge, Val M. ;
Kirchin, Miles A. ;
Stemmer, Alto ;
Naul, L. Gill ;
Williams, Kenneth D. ;
Reith, Wolfgang ;
Buecker, Arno ;
Schneider, Guenther .
INVESTIGATIVE RADIOLOGY, 2009, 44 (06) :351-359