Performance studies of an optical fiber OSL/RL dosimetry system in pulsed high-intensity radiation beams

被引:5
|
作者
Benoit, David [2 ,3 ]
Dusseau, Laurent [2 ]
Glaser, Maurice [1 ]
Mukherjee, Bhaskar [4 ]
Ravotti, Federico [1 ]
机构
[1] CERN, Dept Phys, CH-1211 Geneva 23, Switzerland
[2] Univ Montpellier 2, IES, F-34095 Montpellier, France
[3] Ctr Leon Berard, Dept Radiotherapie, F-69008 Lyon, France
[4] MSK Grp, DESY, D-22607 Hamburg, Germany
关键词
SrS:Ce; Sm; Optically Stimulated Luminescence; Radio-Luminescence; Radiation-hard optical fiber; On-line radiation monitoring; SRSCE; SM PHOSPHOR; ACCELERATOR; FACILITIES; CERN;
D O I
10.1016/j.radmeas.2009.12.028
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The SrS:Ce,Sm phosphor is suitable for operation in harsh radiation environments where real-time dosimetry measurements are needed to survey the Total Ionizing Dose (TID) damage in electronic components. For these applications, the OSL and RL emissions from this phosphor can be exploited by mounting the SrS crystal at the edge of a single, radiation-hard, optical fiber. In this work we present an exhaustive characterization of this real-time OSL/RL probe including stability, repeatability of the measured signals, dosimetry performance and measurements of the temporal behavior of the RI signal in pulsed particle beams. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:688 / 690
页数:3
相关论文
共 50 条
  • [1] CONDUCTIMETRIC DOSIMETRY - A CALORIMETRIC METHOD FOR MEASURING HIGH-INTENSITY PULSED RADIATION
    SCHMIDT, KH
    BUCK, WL
    RADIATION RESEARCH, 1969, 40 (03) : 473 - &
  • [2] PULSED SYSTEM FOR OBTAINING MICRODOSIMETRIC DATA WITH HIGH-INTENSITY BEAMS
    ZAIDER, M
    DICELLO, JF
    HIEBERT, RD
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1978, 25 (01) : 202 - 204
  • [3] Radiotherapy Using High-Intensity Pulsed Radiation Beams (FLASH): A Radiation-Chemical Perspective
    Wardman, Peter
    RADIATION RESEARCH, 2020, 194 (06) : 607 - 617
  • [4] Studies on high-intensity pulsed molecular beams and flows interacting with a solid surface
    Makarov, GN
    PHYSICS-USPEKHI, 2003, 46 (09) : 889 - 914
  • [5] A novel wire scanner for high-intensity pulsed beams
    Back, CH
    King, F
    Collet, G
    Kirby, R
    Field, C
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 435 (03): : 318 - 325
  • [6] A transparent vacuum window for high-intensity pulsed beams
    Monteil, Michael
    Blanco, Juan
    Veness, Raymond
    VACUUM, 2011, 85 (12) : 1165 - 1169
  • [7] Novel wire scanner for high-intensity pulsed beams
    Stanford Linear Accelerator Center, Stanford University, Mail Stop 65, P.O. Box 4349, Stanford, CA 94309, United States
    不详
    Nucl Instrum Methods Phys Res Sect A, 3 (318-325):
  • [8] Test of an optical transition radiation detector for high-intensity proton beams at FNAL
    Scarpine, VE
    Lumpkin, AH
    Schappert, W
    Tassotto, GR
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 1161 - 1164
  • [9] Glazing of ceramic surfaces with high-intensity pulsed ion beams
    Kucinski, J
    Langner, J
    Piekoszewski, J
    Adami, M
    Miotello, A
    Guzman, L
    SURFACE & COATINGS TECHNOLOGY, 1996, 84 (1-3): : 329 - 333
  • [10] Generation of high-intensity pulsed low-energy electron beams in a channel spark system
    G. E. Ozur
    S. A. Popov
    V. F. Fedushchak
    A. V. Saushkin
    Technical Physics Letters, 2006, 32 : 928 - 931