Investigation of a solid-state detector for advanced computed tomography

被引:32
|
作者
Hsieh, J [1 ]
Gurmen, OE
King, KF
机构
[1] GE, Med Syst, Appl Sci Lab, Milwaukee, WI 53201 USA
[2] GE, Med Syst, Detector Engn, Milwaukee, WI 53201 USA
关键词
computed tomography; primary speed and afterglow; recursive correction; solid-state detector;
D O I
10.1109/42.887840
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Utilization of solid-state detectors for computed tomography (CT) has been the focus of many studies. Previous phantom and clinical experiments have shown that one of the important performance parameters for the solid-state detector is the primary speed and afterglow, In this paper, we present a detailed investigation on the signal decay characteristics of the HiLight (GE Medical Systems, Milwaukee, WI) scintillating detector, The detector primary speed and afterglow are modeled by a multiexponential function and fully characterized by a set of time constants and relative strengths. The sensitivity of these parameters to X-ray photon energy, detector aging, and radiation exposure is then established and analyzed. No statistically significant variation is observed in these parameters due to changes in the above external variables. The impact of various decay time constants on CT image quality, such as spatial resolution, noise, and artifacts, is subsequently illustrated with computer simulations and phantom experiments, Finally, an algorithmic correction scheme is derived to compensate for detector afterglow The correction scheme employs a recursive filter to remove adverse effects of the detector decay on image quality. Experimental results have shown that the correction scheme successfully restores system spatial resolution, produces a more homogeneous noise pattern, and eliminates ring-band image artifacts due to detector afterglow. The effectiveness and robustness of the correction scheme are demonstrated by extensive phantom and clinical experiments.
引用
收藏
页码:930 / 940
页数:11
相关论文
共 50 条
  • [1] An X-ray computed tomography demonstrator using a CZT solid-state detector
    Claesson, T
    Kerek, A
    Molnár, J
    Novák, D
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 487 (1-2): : 202 - 208
  • [2] Solid-state detector module design for Computed mammo-Tomography (CmT) system
    Park, Shin-Woong
    Yi, Yun
    2006 CONFERENCE ON OPTOELECTRONIC AND MICROELECTRONIC MATERIALS & DEVICES, 2006, : 239 - 242
  • [3] High-resolution X-ray computed tomography using a solid-state linear detector
    Kaftandjian, V.
    Peix, G.
    Babot, D.
    Peyrin, F.
    Journal of X-Ray Science and Technology, 1996, 6 (01):
  • [4] PRaVDA: The first solid-state system for proton computed tomography
    Esposito, Michela
    Waltham, Chris
    Taylor, Jonathan T.
    Manger, Sam
    Phoenix, Ben
    Price, Tony
    Poludniowski, Gavin
    Green, Stuart
    Evans, Philip M.
    Allport, Philip P.
    Manolopulos, Spyros
    Nieto-Camero, Jaime
    Symons, Julyan
    Allinson, Nigel M.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 55 : 149 - 154
  • [5] SOLID-STATE NULL DETECTOR
    SHABET, E
    INSTRUMENTS & CONTROL SYSTEMS, 1971, 44 (06): : 25 - &
  • [6] A SOLID-STATE NEUTRON DETECTOR
    VELBECK, K
    KING, CW
    TAWIL, RA
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1984, 31 (01) : 360 - 361
  • [7] Investigation of solid-state photomultipliers for positron emission tomography scanners
    Lee, Jae Sung
    Ito, Mikiko
    Sim, Kwang-Souk
    Hong, Byungsik
    Lee, Kyung Sei
    Muhammad, Jamil
    Rhee, June Tak
    Lee, Geon Song
    Park, Kwang Suk
    Song, In Chan
    Hong, Seong Jong
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2007, 50 (05) : 1332 - 1339
  • [8] COMBINED SOLID-STATE DETECTOR FOR RADIOMETRY
    RYZHIKOV, VD
    SOKHIN, VP
    DANSHIN, EA
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1990, 33 (06) : 1294 - 1296
  • [9] ALPHA MONITOR WITH SOLID-STATE DETECTOR
    SHEEN, EM
    NUCLEAR INSTRUMENTS & METHODS, 1962, 17 (02): : 140 - 144
  • [10] A solid-state VRX CT detector
    DiBianca, FA
    Melnyk, R
    Sambari, A
    Jordan, LM
    Laughter, JS
    Zou, P
    MEDICAL IMAGING 2000: PHYSICS OF MEDICAL IMAGING, 2000, 3977 : 205 - 210