EUS with CT improves efficiency and structure identification over conventional EUS

被引:23
作者
Vosburgh, Kirby G.
Stylopoulos, Nicholas
Estepar, Raul San Jose
Ellis, Randy E.
Samset, Eigil
Thompson, Christopher C.
机构
[1] Massachusetts Gen Hosp, Ctr Integrat Med & Innovat Technol, Dept Surg, Boston, MA 02114 USA
[2] Brigham & Womens Hosp, Dept Radiol, Boston, MA 02115 USA
[3] Brigham & Womens Hosp, Dept Med, Boston, MA 02115 USA
关键词
D O I
10.1016/j.gie.2006.09.021
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: EUS is complicated because of the subtleties of US interpretation, small fields of observation, and uncertainty of probe position and orientation. Objective: Improved EUS performance is sought by providing contextual information to support US probe positioning and identification of features in US images. Our aims were to demonstrate the feasibility of the image registered gastroscopic US (IRGUS) system in a porcine model and to compare the effectiveness and the efficiency of IRGUS with traditional EUS. Design: Animal feasibility study. Interventions: The IRGUS system uses preprocedure CT and miniature US probe trackers to create real-time synthetic displays of the position of the probe tip and a matched slice of CT data for comparison with the US image. Participants used EUS and IRGUS systems in a porcine model to evaluate the speed and accuracy of structure identification. Main Outcome Measurements: The performance and utility of lRGUS were determined by the number of correctly identified structures in a timed trial, kinematic variables, and a structured survey Results: IRGUS was twice as effective as EUS in localizing and identifying individual structures. In timed trials, IRGUS users identified over 25% more structures than EUS users. Improvement in examination efficiency and accuracy of feature identification was statistically significant, and 90% of the users preferred IRGUS to EUS for these tasks. Conclusions: IRGUS appears feasible and may be superior to conventional EUS in efficiency and accuracy of probe positioning and in image interpretation. IRGUS has the potential to shorten the EUS learning curve and to broaden the adoption of EUS techniques by gastroenterologists.
引用
收藏
页码:866 / 870
页数:5
相关论文
共 10 条
[1]  
Brugge WR, 2002, AM J GASTROENTEROL, V97, P2701
[2]  
Di Stasi M, 1998, AM J GASTROENTEROL, V93, P1329
[3]  
Estépar RSJ, 2006, LECT NOTES COMPUT SC, V4190, P445
[4]  
HART S G, 1988, P139
[5]   Intraoperative ultrasonography - History, current state of the art, and future directions [J].
Kane, RA .
JOURNAL OF ULTRASOUND IN MEDICINE, 2004, 23 (11) :1407-1420
[6]  
Rattner DW, 1996, ARCH SURG-CHICAGO, V131, P366
[7]   ENDOSCOPIC ULTRASOUND IN PANCREATIC TUMOR-DIAGNOSIS [J].
ROSCH, T ;
LORENZ, R ;
BRAIG, C ;
FEUERBACH, S ;
SIEWERT, JR ;
SCHUSDZIARRA, V ;
CLASSEN, M .
GASTROINTESTINAL ENDOSCOPY, 1991, 37 (03) :347-352
[8]   Computer-enhanced laparoscopic training system (CELTS) - Bridging the gap [J].
Stylopoulos, N ;
Cotin, S ;
Maithel, SK ;
Ottensmeyer, M ;
Jackson, PG ;
Bardsley, RS ;
Neumann, PF ;
Rattner, DW ;
Dawson, SL .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2004, 18 (05) :782-789
[9]  
THOMPSON CC, 2006, DIG DIS WEEK MAY 21
[10]  
VOSBURGH KG, 2006, CARS ISCAS JUN 26 JU