Mini-fluid Challenge of 100 ml of Crystalloid Predicts Fluid Responsiveness in the Operating Room

被引:80
作者
Biais, Matthieu [1 ,2 ,3 ]
de Courson, Hugues [1 ]
Lanchon, Romain [1 ]
Pereira, Bruno [4 ]
Bardonneau, Guillaume [1 ]
Griton, Marion [1 ]
Sesay, Musa [1 ]
Nouette-Gaulain, Karine [1 ,3 ,5 ]
机构
[1] Bordeaux Univ Hosp, Dept Anesthesiol & Crit Care 3, Bordeaux, France
[2] INSERM, U1034, Biol Cardiovasc Dis, Pessac, France
[3] Univ Bordeaux, Bordeaux, France
[4] CHU Clermont Ferrand, Delegat Rech Clin & Innovat, Biostat Unit, Clermont Ferrand, France
[5] INSERM, U12 11, Lab Malad Rares Genet & Metab, Bordeaux, France
关键词
MAJOR GASTROINTESTINAL SURGERY; PULSE PRESSURE VARIATIONS; CARDIAC-OUTPUT; VOLUME RESPONSIVENESS; HYDROXYETHYL STARCH; CONTOUR ANALYSIS; SALINE; OUTCOMES; TRIAL; ASSOCIATION;
D O I
10.1097/ALN.0000000000001753
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Mini-fluid challenge of 100 ml colloids is thought to predict the effects of larger amounts of fluid (500 ml) in intensive care units. This study sought to determine whether a low quantity of crystalloid (50 and 100 ml) could predict the effects of 250 ml crystalloid in mechanically ventilated patients in the operating room. Methods: A total of 44 mechanically ventilated patients undergoing neurosurgery were included. Volume expansion (250 ml saline 0.9%) was given to maximize cardiac output during surgery. Stroke volume index (monitored using pulse contour analysis) and pulse pressure variations were recorded before and after 50 ml infusion (given for 1 min), after another 50 ml infusion (given for 1 min), and finally after 150 ml infusion (total = 250 ml). Changes in stroke volume index induced by 50, 100, and 250 ml were recorded. Positive fluid challenges were defined as an increase in stroke volume index of 10% or more from baseline after 250 ml. Results: A total of 88 fluid challenges were performed (32% of positive fluid challenges). Changes in stroke volume index induced by 100 ml greater than 6% (gray zone between 4 and 7%, including 19% of patients) predicted fluid responsiveness with a sensitivity of 93% (95% CI, 77 to 99%) and a specificity of 85% (95% CI, 73 to 93%). The area under the receiver operating curve of changes in stroke volume index induced by 100 ml was 0.95 (95% CI, 0.90 to 0.99) and was higher than those of changes in stroke volume index induced by 50 ml (0.83 [95% CI, 0.75 to 0.92]; P = 0.01) and pulse pressure variations (0.65 [95% CI, 0.53 to 0.78]; P < 0.005). Conclusions: Changes in stroke volume index induced by rapid infusion of 100 ml crystalloid predicted the effects of 250 ml crystalloid in patients ventilated mechanically in the operating room.
引用
收藏
页码:450 / 456
页数:7
相关论文
共 42 条
  • [1] Accuracy of ultrasound B-lines score and E/Ea ratio to estimate extravascular lung water and its variations in patients with acute respiratory distress syndrome
    Bataille, Benoit
    Rao, Guillaume
    Cocquet, Pierre
    Mora, Michel
    Masson, Bruno
    Ginot, Jean
    Silva, Stein
    Moussot, Pierre-Etienne
    [J]. JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2015, 29 (01) : 169 - 176
  • [2] Wet, dry or something else?
    Bellamy, M. C.
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2006, 97 (06) : 755 - 757
  • [3] The effects of goal-directed fluid therapy based on dynamic parameters on post-surgical outcome: a meta-analysis of randomized controlled trials
    Benes, Jan
    Giglio, Mariateresa
    Brienza, Nicola
    Michard, Frederic
    [J]. CRITICAL CARE, 2014, 18 (05) : 1 - 11
  • [4] Clinical relevance of pulse pressure variations for predicting fluid responsiveness in mechanically ventilated intensive care unit patients: the grey zone approach
    Biais, Matthieu
    Ehrmann, Stephan
    Mari, Arnaud
    Conte, Benjamin
    Mahjoub, Yazine
    Desebbe, Olivier
    Pottecher, Julien
    Lakhal, Karim
    Benzekri-Lefevre, Dalila
    Molinari, Nicolas
    Boulain, Thierry
    Lefrant, Jean-Yves
    Muller, Laurent
    [J]. CRITICAL CARE, 2014, 18 (06):
  • [5] Case Scenario: Respiratory Variations in Arterial Pressure for Guiding Fluid Management in Mechanically Ventilated Patients
    Biais, Matthieu
    Ouattara, Alexandre
    Janvier, Gerard
    Sztark, Francois
    [J]. ANESTHESIOLOGY, 2012, 116 (06) : 1354 - 1361
  • [6] Hemodynamic monitoring and management in patients undergoing high risk surgery: a survey among North American and European anesthesiologists
    Cannesson, Maxime
    Pestel, Gunther
    Ricks, Cameron
    Hoeft, Andreas
    Perel, Azriel
    [J]. CRITICAL CARE, 2011, 15 (04):
  • [7] Assessing the Diagnostic Accuracy of Pulse Pressure Variations for the Prediction of Fluid Responsiveness A "Gray Zone" Approach
    Cannesson, Maxime
    Le Manach, Yannick
    Hofer, Christoph K.
    Goarin, Jean Pierre
    Lehot, Jean-Jacques
    Vallet, Benoit
    Tavernier, Benoit
    [J]. ANESTHESIOLOGY, 2011, 115 (02) : 231 - 241
  • [8] Carpenter J, 2000, STAT MED, V19, P1141, DOI 10.1002/(SICI)1097-0258(20000515)19:9<1141::AID-SIM479>3.0.CO
  • [9] 2-F
  • [10] Crystalloids Versus Colloids: Exploring Differences in Fluid Requirements by Systematic Review and Meta-Regression
    Cortes, Diego Orbegozo
    Barros, Teresa Gamarano
    Njimi, Hassane
    Vincent, Jean-Louis
    [J]. ANESTHESIA AND ANALGESIA, 2015, 120 (02) : 389 - 402