The value of three-dimensional echocardiography in the diagnosis and management of ruptured sinus of Valsalva aneurysm: a case report

被引:4
作者
Daud, Elias [1 ,2 ]
Or, Tsafrir [1 ,2 ]
Adler, Zvi [3 ,4 ]
Shturman, Alexander [1 ,2 ]
机构
[1] Galilee Med Ctr, Cardiol Dept, POB 21, IL-22100 Nahariyya, Israel
[2] Bar Ilan Univ, Azrieli Fac Med, Henrietta Szold 8, IL-1311502 Safed, Israel
[3] Cardiac Surg Dept, Rambam Healthcare Campus,HaAliy HaShniya 8,POB 96, IL-31096 Haifa, Israel
[4] Technion, Rappaport Fac Med, Efron 1, IL-3525422 Haifa, Israel
关键词
Three-dimensional echocardiography; Congenital cardiac anomaly; Cardiogenic shock; Ruptured sinus of Valsalva aneurysm; Case report;
D O I
10.1093/ehjcr/ytz111
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background A sinus of Valsalva aneurysm (SVA) is a rare cardiac anomaly. Most SVA's rupture into right heart chambers and can be classified using the modified Sakakibara classification according to the site of rupture. Transoesophageal echocardiography (TOE) is a useful diagnostic tool and aides in treatment planning in patients with congenital anomalies in emergency situations. Three-dimensional TOE (3D-TOE) provides additional value over standard TOE. Case summary A 38-year-old man with a reported history of ventricular septal defect (VSD) presented to the emergency department complaining of chest pain and epigastric pain lasting several days. Physical examination revealed a continuous heart murmur and signs of acute heart failure. A 3D-TOE revealed an SVA rupture into the right ventricle (Type IIIv) but no evidence of a VSD. Urgent aortic valve replacement with correction of the ruptured SVA was performed. Neither a VSD nor signs of endocarditis were found during surgical exploration. The patient was discharged on post-operative Day 5 in good condition. Discussion A sinus of Valsalva aneurysm is a rare cardiac condition. Ventricular septal defect, bicuspid aortic valve, or aortic valve regurgitation may coexist with SVA. Xin-Jin et al. classified a ruptured SVA into five types according to the site of rupture. Transoesophageal echocardiography is an important tool for diagnosis, anatomical description, and typing of the ruptured SVA. Sinus of Valsalva aneurysm may be misdiagnosed as a VSD, as was the case in our patient, and 3D-TOE can be instrumental for providing both correct diagnosis and critical surgical planning.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] Ruptured Anterior Mitral Leaflet Aneurysm in Aortic Valve Infective Endocarditis-Evaluation by Three-Dimensional Echocardiography
    Kharwar, Rajiv Bharat
    Mohanty, Abhisekh
    Sharma, Akhil
    Narain, Varun Shankar
    Sethi, Rishi
    [J]. ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2014, 31 (03): : E72 - E76
  • [22] Thrombosed sinus of Valsalva aneurysm masquer ading as a cardiac tumour: a case report
    Sato, Wakana
    Seki, Katsuhito
    Yamamoto, Hiroshi
    Watanabe, Hiroyuki
    [J]. EUROPEAN HEART JOURNAL-CASE REPORTS, 2021, 5 (08)
  • [23] Diagnosis of Inferior Sinus Venosus Atrial Septal Defects Using Transthoracic Three-Dimensional Echocardiography
    Chen, Chun-An
    Wang, Jou-Kou
    Hsu, Jui-Yu
    Hsu, Hsao-Hsun
    Chen, Shyh-Jye
    Wu, Mei-Hwan
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2010, 23 (04) : 457.e4 - 457.e6
  • [24] Incremental Value of Three-Dimensional Echocardiography over the Two-Dimensional Technique in the Assessment of Combined Sinus of Valsalva Rupture into the Right Ventricle and Adjacent Perimembranous Ventricular Septal Defect
    Ahmed, Mustafa I.
    Gok, Gulay
    Yuzbas, Burcu
    Burkhart, Joshua
    Escanuela, Maximiliano German Amado
    Alli, Oluseun O.
    Nanda, Navin C.
    [J]. ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2014, 31 (06): : 779 - 782
  • [25] Anesthetic management of cesarean delivery in parturients with ruptured sinus of Valsalva aneurysm CARE-compliant 2 case reports and literature review
    Fang, Gang
    Li, Man
    Li, Jian
    Lin, Li
    Mei, Wei
    [J]. MEDICINE, 2017, 96 (19)
  • [26] Three-dimensional echocardiography in the diagnosis of pacemaker lead perforation
    Akinori Sugano
    Yoshihiro Seo
    Akiko Atsumi
    Masayoshi Yamamoto
    Tomoko Machino-Ohtuska
    Ryo Kawamura
    Hideki Nakajima
    Tomoko Ishizu
    Kazutaka Aonuma
    [J]. Journal of Echocardiography, 2012, 10 (4) : 141 - 142
  • [27] Resolution of post-anaesthesia aortic regurgitation by repair of a ruptured sinus of Valsalva aneurysm: 5 case reports
    Qian Xue
    Chun Yang
    Xiu Han
    [J]. BMC Cardiovascular Disorders, 20
  • [28] Rupture of a non sinus of Valsalva aneurysm during pregnancy: Case report and review of literatures
    Huang, T. T.
    Shan, J. G.
    Lin, J. H.
    [J]. NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2023, 26 (02) : 250 - 252
  • [29] Resolution of post-anaesthesia aortic regurgitation by repair of a ruptured sinus of Valsalva aneurysm: 5 case reports
    Xue, Qian
    Yang, Chun
    Han, Xiu
    [J]. BMC CARDIOVASCULAR DISORDERS, 2020, 20 (01)
  • [30] Three-dimensional transesophageal echocardiography incremental value in a rare case of a bileaflet tricuspid valve
    Mahmoud, Hani M.
    Walley, Hossam
    Hosny, Hatem
    Yacoub, Magdi
    [J]. ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2016, 33 (09): : 1438 - 1440