On-line automatic SPE-CE coupling for the determination of biological markers in urine

被引:28
作者
Ruiz-Jimenez, Jose
Mata-Granados, Jose M.
Luque de Castro, Maria Dolores
机构
[1] Univ Cordoba, Dept Analyt Chem, E-14071 Cordoba, Spain
[2] SANYRES I&D, Grp PRASA, Cordoba, Spain
关键词
biological markers; CE; on-line; SPE-CE coupling; prospekt; urine;
D O I
10.1002/elps.200600340
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Automatic SPE has been coupled on-line to CE by a transfer tube and the replenishment system of the CE instrument. The approach allows the target analytes (viz. creatinine, creatine, xanthine, hypoxanthine, uric acid, p-aminohippuric acid and ascorbic acid in urine samples) to be removed from the sample matrix, cleaned up, preconcentrated and injected into the capillary. The detection limits range between 0.14 and 4.50 mu g/mL, the quantification limits between 0.45 and 15.0 mu g/mL, and linear dynamic ranges - which include the reference healthy human values - from the quantification limits to 1332 mu g/mL. The precision, expressed as RSD, ranges between 0.38 and 2.22% for repeatability and between 1.79 and 7.61% for within-laboratory reproducibility. The errors, expressed as RSD for all compounds, range between 0.20 and 6.90%. The time for automatic SPE and that necessary for the individual separation-detection of the target analytes are 13 and 12 min, respectively; the analysis frequency is 5 h(-1). The accuracy of the method and potential matrix effects were studied by using spiked samples and recoveries between 96.00 and 103.07 % were obtained. The proposed method was applied to samples from healthy young students.
引用
收藏
页码:789 / 798
页数:10
相关论文
共 20 条
[1]   Simultaneous determination of inulin and p-aminohippuric acid (PAH) in human plasma and urine by high-performance liquid chromatography [J].
Baccard, N ;
Hoizey, G ;
Frances, C ;
Lamiable, D ;
Trenque, T ;
Millart, H .
ANALYST, 1999, 124 (06) :833-836
[2]  
BRIGDEN ML, 1992, CLIN CHEM, V38, P426
[3]   High-throughput multi-analyte screening for renal disease using capillary electrophoresis [J].
Clark, EA ;
Fanguy, JC ;
Henry, CS .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2001, 25 (5-6) :795-801
[4]  
CLARK J, 1985, KIDNEYS BALANCING FL
[5]   A COLORIMETRIC METHOD USING URICASE AND PEROXIDASE FOR DETERMINATION OF URIC ACID [J].
DOMAGK, GF ;
SCHLICKE, HH .
ANALYTICAL BIOCHEMISTRY, 1968, 22 (02) :219-&
[6]   Simultaneous determination of the urinary metabolites of toluene, xylene and styrene using high-performance capillary electrophoresis - Comparison with high-performance liquid chromatography [J].
Fujii, T ;
Kawabe, S ;
Horike, T ;
Taguchi, T ;
Ogata, M .
JOURNAL OF CHROMATOGRAPHY B, 1999, 730 (01) :41-47
[7]   Direct detection of renal function markers using microchip CE with pulsed electrochemical detection [J].
Garcia, CD ;
Henry, CS .
ANALYST, 2004, 129 (07) :579-584
[8]   Determination of uric acid and p-aminohippuric acid in human saliva and urine using capillary electrophoresis with electrochemical detection -: Potential application in fast diagnosis of renal disease [J].
Guan, YQ ;
Wu, T ;
Ye, JN .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 821 (02) :229-234
[9]  
HALMINGH O, 1998, SIMPLE STRATEGY RAPI
[10]   Creatine supplementation - Its role in human performance [J].
Kraemer, WJ ;
Volek, JS .
CLINICS IN SPORTS MEDICINE, 1999, 18 (03) :651-+