Test and analysis of reliability for electromagnetic relay

被引:12
作者
Li, K [1 ]
Yao, F [1 ]
Lu, JG [1 ]
Li, ZG [1 ]
机构
[1] Hebei Univ Technol, Tianjin 300130, Peoples R China
来源
ELECTRICAL CONTACTS-2000: PROCEEDINGS OF THE FORTY-SIXTH IEEE HOLM CONFERENCE ON ELECTRICAL CONTACTS | 2000年
关键词
electromagnetic relay; reliability test; reliability analysis;
D O I
10.1109/HOLM.2000.889915
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Because the Relays are widely used in automatic control system and communication system, the reliability of relays is very important. The electromagnetic relays, type 155, were tested for their reliability in our paper. The test load was DC 24Vx0.1A. During the test, the contact voltage drop, closing time and opening time were monitored and measured. In the end of test, we estimated the reliability of the relay according to the results of test, and analyzed the failure mode. The failure mechanisms were analyzed by observing the surfaces of failure contacts. We put forward a method for reducing the failure rate of the relay.