Risk Factors for Infections Involving Cardiac Implanted Electronic Devices

被引:117
|
作者
Birnie, David H. [1 ]
Wang, Jia [2 ]
Alings, Marco [3 ]
Philippon, Francois [4 ]
Parkash, Ratika [5 ]
Manlucu, Jaimie [6 ]
Angaran, Paul [7 ]
Rinne, Claus [8 ]
Coutu, Benoit [9 ]
Low, R. Aaron [10 ]
Essebag, Vidal [11 ]
Morillo, Carlos [12 ]
Redfearn, Damian [13 ]
Toal, Satish [14 ]
Becker, Giuliano [15 ]
Degrace, Michel [16 ]
Thibault, Bernard [17 ]
Crystal, Eugene [18 ]
Tung, Stanley [19 ]
LeMaitre, John [20 ]
Sultan, Omar [21 ]
Bennett, Matthew [21 ,22 ]
Bashir, Jamil [23 ]
Ayala-Paredes, Felix [24 ]
Gervais, Philippe [4 ]
Rioux, Leon [25 ]
Hemels, Martin E. W. [26 ,27 ]
Bouwels, Leon H. R. [28 ]
Exner, Derek V. [12 ]
Dorian, Paul [7 ]
Connolly, Stuart J. [2 ]
Longtin, Yves [29 ]
Krahn, Andrew D. [23 ]
机构
[1] Univ Ottawa, Inst Heart, Ottawa, ON, Canada
[2] McMaster Univ, Hamilton Hlth Sci, Populat Hlth Res Inst, Hamilton, ON, Canada
[3] Amphia Ziekenhuis & Working Grp Cardiovasc Res Ne, Breda, Netherlands
[4] Laval Univ, Inst Univ Cardiol & Pneumol Quebec, Quebec City, PQ, Canada
[5] Queen Elizabeth 2 Hlth Sci Ctr, Halifax, NS, Canada
[6] Western Univ, London Hlth Sci, Lawson Hlth Res Inst, London, ON, Canada
[7] Univ Toronto, St Michael Hosp, Div Cardiol, Dept Med, Toronto, ON, Canada
[8] St Marys Gen Hosp, Kitchener, ON, Canada
[9] Univ Montreal, Ctr Hosp Univ Montreal, Montreal, PQ, Canada
[10] Chinook Reg Hosp, Lethbridge, AB, Canada
[11] McGill Univ, Ctr Hlth, Montreal, PQ, Canada
[12] Univ Calgary, Libin Cardiovasc Inst Alberta, Calgary, AB, Canada
[13] Queens Univ, Kingston Gen Hosp, Kingston, ON, Canada
[14] Horizon Hlth Network, St John, NB, Canada
[15] Univ Montreal, Hop Sacre Coeur Montreal, Montreal, PQ, Canada
[16] Hotel Dieu Levis, Levis, PQ, Canada
[17] Montreal Heart Inst, Montreal, PQ, Canada
[18] Sunnybrook Hlth Sci Ctr, Toronto, ON, Canada
[19] Univ British Columbia, St Pauls Hosp, Vancouver, BC, Canada
[20] Royal Columbian Hosp, New Westminster, BC, Canada
[21] Saskatchewan Hlth Author, Regina Gen Hosp, Regina, SK, Canada
[22] Univ British Columbia, Vancouver Gen Hosp, Vancouver, BC, Canada
[23] Univ British Columbia, Vancouver, BC, Canada
[24] Ctr Hosp Univ Sherbrooke, Sherbrooke, PQ, Canada
[25] Ctr Sante & Serv Sociaux Rimouski Neigette, Rimouski, PQ, Canada
[26] Rijnstate Hosp, Arnhem, Netherlands
[27] Radboud Univ Nijmegen, Med Ctr, Nijmegen, Netherlands
[28] Canisius Wilhelmina Ziekenhuis, Nijmegen, Netherlands
[29] McGill Univ, Jewish Gen Hosp Sir Mortimer B Davis, Montreal, PQ, Canada
关键词
antibiotics; cardiac implantable electronic device; implantable cardioverter defibrillator; infection; pacemaker; MANAGEMENT; MORTALITY; PREVENTION; PACEMAKER; TRIAL; TIME;
D O I
10.1016/j.jacc.2019.09.060
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Cardiac implantable electronic device infection is a major complication that usually requires device removal. PADIT (Prevention of Arrhythmia Device Infection Trial) was a large cluster crossover trial of conventional versus incremental antibiotics. OBJECTIVES This study sought to investigate independent predictors of device infection in PADIT and develop a novel infection risk score. METHODS In brief, over 4 6-month periods, 28 centers used either conventional or incremental prophylactic antibiotic treatment in all patients. The primary outcome was hospitalization for device infection within 1 year (blinded endpoint adjudication). Multivariable logistic prediction modeling was used to identify the independent predictors and develop a risk score for device infection. The prediction models were internally validated with bootstrap methods. RESULTS Device procedures were performed in 19,603 patients, and hospitalization for infection occurred in 177 (0.90%) within 1 year of follow-up. The final prediction model identified 5 independent predictors of device infection (prior procedures [P], age [A], depressed renal function [D], immunocompromised [I], and procedure type [T]) with an optimism-corrected C-statistic of 0.704 (95% confidence interval: 0.660 to 0.744). A PADIT risk score ranging from 0 to 15 points classified patients into low (0 to 4), intermediate (5 to 6) and high (>= 7) risk groups with rates of hospitalization for infection of 0.51%, 1.42%, and 3.41%, respectively. CONCLUSIONS This study identified 5 independent predictors of device infection and developed a novel infection risk score in the largest cardiac implantable electronic device trial to date, warranting validation in an independent cohort. The 5 independent predictors in the PADIT score are readily adopted into clinical practice. (C) 2019 Published by Elsevier on behalf of the American College of Cardiology Foundation.
引用
收藏
页码:2845 / 2854
页数:10
相关论文
共 50 条
  • [21] Preoperative checklist to reduce the risk of cardiac implantable electronic device infections
    Ziacchi, Matteo
    Massaro, Giulia
    Angeletti, Andrea
    Statuto, Giovanni
    Diemberger, Igor
    Martignani, Cristian
    Galie, Nazzareno
    Biffi, Mauro
    Boriani, Giuseppe
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2022, 45 (02): : 262 - 269
  • [22] Cardiac Implantable Electronic Device Therapy Permanent Pacemakers, Implantable Cardioverter Defibrillators, and Cardiac Resynchronization Devices
    Steffen, Melanie M.
    Osborn, Jeffery S.
    Cutler, Michael J.
    MEDICAL CLINICS OF NORTH AMERICA, 2019, 103 (05) : 931 - +
  • [23] Nonstaphylococcal Infections of Cardiac Implantable Electronic Devices
    Viola, George M.
    Awan, Leah L.
    Darouiche, Rabih O.
    CIRCULATION, 2010, 121 (19) : 2085 - 2091
  • [24] Antibiotic-Eluting Envelopes for the Prevention of Cardiac Implantable Electronic Device Infections: Rationale, Efficacy, and Cost-Effectiveness
    Traykov, Vassil
    Blomstrom-Lundqvist, Carina
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [25] Radiation therapy in patients with cardiac implantable electronic devices
    Niedziela, Jacek T.
    Blamek, Slawomir
    Gadula-Gacek, Elibieta
    Gorol, Jaroslaw
    Kurek, Anna
    Witek, Mateusz
    Wojtaszczyk, Adam
    Plaza, Przemyslaw
    Miszczyk, Leszek
    Gasior, Mariusz
    Tajstra, Mateusz
    KARDIOLOGIA POLSKA, 2021, 79 (02) : 156 - 160
  • [26] Cardiac implantable electronic device infections: Incidence, risk factors, and the effect of the AigisRx antibacterial envelope
    Mittal, Suneet
    Shaw, Richard E.
    Michel, Kimberly
    Palekar, Rachel
    Arshad, Aysha
    Musat, Dan
    Preminger, Mark
    Sichrovsky, Tina
    Steinberg, Jonathan S.
    HEART RHYTHM, 2014, 11 (04) : 595 - 601
  • [27] Detection of new atrial fibrillation in patients with cardiac implanted electronic devices and factors associated with transition to higher device-detected atrial fibrillation burden
    Boriani, Giuseppe
    Glotzer, Taya V.
    Ziegler, Paul D.
    De Melis, Mirko
    Stefano, Lorenza Mangoni di S.
    Sepsi, Milan
    Landolina, Maurizio
    Lunati, Maurizio
    Lewalter, Thorsten
    Camm, A. John
    HEART RHYTHM, 2018, 15 (03) : 376 - 383
  • [28] Antibiotic prophylaxis based on individual infective risk stratification in cardiac implantable electronic device: the PRACTICE study
    Malagu, Michele
    Vitali, Francesco
    Brieda, Alessandro
    Cimaglia, Paolo
    De Raffele, Martina
    Tazzari, Enea
    Musolino, Cristina
    Balla, Cristina
    Serenelli, Matteo
    Cultrera, Rosario
    Rapezzi, Claudio
    Bertini, Matteo
    EUROPACE, 2022, 24 (03): : 413 - 420
  • [29] Infections of cardiac implantable electronic devices: Epidemiology, classification, treatment, and prognosis
    Slawinski, Grzegorz
    Lewicka, Ewa
    Kempa, Maciej
    Budrejko, Szymon
    Raczak, Grzegorz
    ADVANCES IN CLINICAL AND EXPERIMENTAL MEDICINE, 2019, 28 (02): : 263 - 270
  • [30] Infections of cardiac implantable electronic devices: Epidemiology, mechanisms, and preventive measures
    Traykov, Vassil
    Dzhinsov, Krasimir
    Matusik, Pawel