Multidetector CT of the paranasal sinus: Potential for radiation dose reduction

被引:51
作者
Brem, Matthias H.
Zamani, Amir A.
Riva, Roberto
Zou, Kelly H.
Rumboldt, Zoran
Hennig, Friedrich F.
Kikinis, Ron
Norbash, Alexander M.
Schoepf, U. Joseph [1 ]
机构
[1] Harvard Univ, Brigham & Womens Hosp, Sch Med, Dept Radiol, Boston, MA 02115 USA
[2] Univ Erlangen Nurnberg, Dept Surg Ortheped Surg, Erlangen, Germany
[3] Harvard Univ, Sch Med, Dept Hlth Care Policy, Boston, MA 02115 USA
[4] Med Univ S Carolina, Dept Radiol, Charleston, SC 29425 USA
[5] Boston Univ, Sch Med, Dept Radiol, Boston, MA 02118 USA
关键词
D O I
10.1148/radiol.2433050207
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of the study was to retrospectively determine the potential for radiation dose reduction at multidetector computed tomography (CT) of the paranasal sinus by using computer simulation of the effect of low-radiation dose acquisition on diagnostic image quality. This HIPAA compliant study was approved by the institutional human research committee. The need for informed patient consent was waived. Twenty patients underwent four-section CT at 120 kV, 170 mAs, and 4 x 1-mm collimation. Artificial image noise was added to the CT raw data by using a dedicated software platform. Acquisitions with effective tube currents of 134, 100, 67, and 33 mAs were simulated. Each raw data set was reconstructed with bone and soft-tissue algorithms, and two radiologists independently rated the images in blinded fashion. A two-sided paired Student t test was used for statistical analysis. The lowest radiation dose that still provided diagnostic quality was <= 67 effective mAs for osseous structures and <= 134 effective mAs for the optic nerve and the inferior rectus muscle. On the basis of the results, tube currents can be lowered and radiation dose reduced by 20%.
引用
收藏
页码:847 / 852
页数:6
相关论文
共 13 条
[1]   COMPUTED TOMOGRAPHIC SCANNING IN CHILDREN - COMPARISON OF RADIATION-DOSE AND RESOLVING POWER OF COMMERCIAL CT SCANNERS [J].
BRASCH, RC ;
BOYD, DP ;
GOODING, CA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1978, 131 (01) :95-101
[2]   A new low-dose CT examination compared with standard-dose CT in the diagnosis of acute sinusitis [J].
Hagtvedt, T ;
Aalokken, TM ;
Notthellen, J ;
Kolbenstvedt, A .
EUROPEAN RADIOLOGY, 2003, 13 (05) :976-980
[3]   Low-dose CT of the paranasal sinuses with eye lens protection: effect on image quality and radiation dose [J].
Hein, E ;
Rogalla, P ;
Klingebiel, R ;
Hamm, B .
EUROPEAN RADIOLOGY, 2002, 12 (07) :1693-1696
[4]  
Hopper KD, 2001, AM J NEURORADIOL, V22, P1194
[5]   RADIATION-DOSE TO THE LENS FROM COMPUTED-TOMOGRAPHY SCANNING IN A NEURORADIOLOGY DEPARTMENT [J].
MACLENNAN, AC ;
HADLEY, DM .
BRITISH JOURNAL OF RADIOLOGY, 1995, 68 (805) :19-22
[6]   PARANASAL SINUSES - LOW-DOSE CT [J].
MARMOLYA, G ;
WIESEN, EJ ;
YAGAN, R ;
HARIA, CD ;
SHAH, AC .
RADIOLOGY, 1991, 181 (03) :689-691
[7]  
MERRIAM GR, 1957, AMER J ROENTGENOL RA, V77, P759
[8]   DETERMINATIONS OF ORGAN DOSES AND EFFECTIVE DOSE EQUIVALENTS FROM COMPUTED TOMOGRAPHIC EXAMINATION [J].
NISHIZAWA, K ;
MARUYAMA, T ;
TAKAYAMA, M ;
OKADA, M ;
HACHIYA, J ;
FURUYA, Y .
BRITISH JOURNAL OF RADIOLOGY, 1991, 64 (757) :20-28
[9]   RADIATION-DOSE IN CT [J].
ROTHENBERG, LN ;
PENTLOW, KS .
RADIOGRAPHICS, 1992, 12 (06) :1225-1243
[10]   An extensible software-based platform for reconstruction and evaluation of CT images [J].
Sennst, DA ;
Kachelriess, M ;
Leidecker, C ;
Schmidt, B ;
Watzke, O ;
Kalender, WA .
RADIOGRAPHICS, 2004, 24 (02) :601-613