Digital neutron-gamma discrimination in a wide energy range using pulse reconstruction method

被引:7
作者
Jamili, S. [1 ]
Bayat, E. [2 ]
Afarideh, H. [3 ]
Davani, F. Abbasi [4 ]
Ghal-Eh, N. [5 ]
机构
[1] Shahid Shamsipour Tech Coll, Tehran, Iran
[2] AEOI, Nucl Sci & Technol Res Ctr, Tehran, Iran
[3] Amirkabir Univ Technol, Dept Energy Engn & Phys, Tehran, Iran
[4] Shahid Beheshti Univ, Radiat Applicat Dept, Tehran, Iran
[5] Damghan Univ, Sch Phys, Damghan, Iran
关键词
NGD; Neutron; Gamma; Pulse reconstruction; TIMING RESPONSE;
D O I
10.1016/j.radphyschem.2014.12.004
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
In this research, based on pulse reconstruction method, digital storage oscilloscopes with an 8-bit digital-to-analog convertor was used to successfully perform the neutron-gamma discrimination with NE213 (or its equivalent BC501A) scintillator anode pulses at minimum discrimination bias value of 95 keVee (or keV electron equivalent). Also, a 100 mCi Am-241-Be source and micro-Curie gamma ray sources (Cs-137 and Na-22) were used for the system calibration and discrimination studies. The results confirm the feasibility and simplicity of the proposed method. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:13 / 16
页数:4
相关论文
共 10 条
  • [1] Lightguide influence on timing response of scintillation detectors
    Bash, Z. Binaei
    Ghal-Eh, N.
    Bayat, E.
    Etaati, G. R.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2013, 82 : 1 - 6
  • [2] Cvachovec J., 2011, THESIS MASARVK U BRN
  • [3] Neutron-gamma discrimination with UGAB scintillator using zero-crossing method
    Divani-Vais, N.
    Bayat, E.
    Firoozabadi, M. M.
    Ghal-Eh, N.
    [J]. RADIATION PROTECTION DOSIMETRY, 2013, 154 (03) : 381 - 384
  • [4] Determination of the neutron spectra around an 18 MV medical LINAC with a passive Bonner sphere spectrometer based on gold foils and TLD pairs
    Esposito, A.
    Bedogni, R.
    Lembo, L.
    Morelli, M.
    [J]. RADIATION MEASUREMENTS, 2008, 43 (2-6) : 1038 - 1043
  • [5] Knoll GF., 2010, Radiation detection and measurement
  • [6] Siddavatam A. P. I., 2014, P INT TECHN C I TECH
  • [7] Modeling NE213 scintillator response to neutrons using an MCNPX-PHOTRACK hybrid code
    Tajik, M.
    Ghal-Eh, N.
    Etaati, G. R.
    Afarideh, H.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 704 : 104 - 110
  • [8] Takaku D., 2011, Prog. Nucl. Sci. Technol, V1, P210, DOI [10.15669/pnst.1.210, DOI 10.15669/PNST.1.210]
  • [9] Study of Pulse Shape Discrimination of Sub-MeV Neutrons from Gamma-rays with Liquid Scintillator
    Yoshioka, M.
    Ueyama, M.
    Koba, Y.
    Nakamura, Y.
    Kajimoto, T.
    Moriguchi, D.
    Uozumi, Y.
    Shigyo, N.
    Sato, D.
    Sanami, T.
    Takada, M.
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2011, 59 (02) : 1971 - 1974
  • [10] On timing response improvement of an NE213 scintillator attached to two PMTs
    Zare, S.
    Ghal-Eh, N.
    Bayat, E.