Evaluation of a novel system for hypothermic oxygenated pulsatile perfusion preservation

被引:18
作者
Doorschodt, Benedict M. [1 ]
Schreinemachers, Marie-Claire J. M. [2 ]
Florquin, Sandrine [3 ]
Lai, Wei [4 ]
Sitzia, Mario [4 ]
Zernecke, Alma [5 ]
Tolba, Rene H. [1 ,4 ]
机构
[1] Univ Aachen, Rhein Westfal TH Aachen, Inst Lab Anim Sci & Expt Surg, D-52074 Aachen, Germany
[2] Univ Amsterdam, Acad Med Ctr, Dept Surg, NL-1105 AZ Amsterdam, Netherlands
[3] Univ Amsterdam, Acad Med Ctr, Dept Pathol, NL-1105 AZ Amsterdam, Netherlands
[4] Univ Bonn, D-5300 Bonn, Germany
[5] Univ Aachen, Rhein Westfal TH Aachen, Inst Pathol, Inst Mol Cardiovasc Res, D-52074 Aachen, Germany
关键词
Kidney; Machine perfusion; Oxygenation; Microcirculation; Pig; BEATING DONOR KIDNEYS; MACHINE PERFUSION; COLD-STORAGE; ISCHEMIA/REPERFUSION INJURY; ORGAN PRESERVATION; LIVER PRESERVATION; GRAFT FUNCTION; TRANSPLANTATION; POLYSOL; MICROCIRCULATION;
D O I
10.1177/039139880903201004
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Recently, a novel innovative machine perfusion (MP) system for hypothermic oxygenated pulsatile perfusion called the Airdrive (AD) has been developed. The aim of the study was to evaluate the biological safety of the AD system for perfusion preservation of kidney grafts in a porcine autotransplantation model using the low-viscosity perfusion solution Polysol (PS) in comparison with cold storage (CS) using PS or the University of Wisconsin solution (UW). In addition, we evaluated real-time microcirculation parameters. At sacrifice, grafts were retrieved for histological analysis and immunohistochemistry. Methods: After assessment of the microcirculation, left kidneys were retrieved. Following the washout, kidneys were preserved for 20 hr using AD-PS, CS-PS or CS-UW. Thereafter, contralateral kidneys were removed followed by heterotopic autotransplantation of the preserved graft. Seven days after transplantation animals were sacrificed with retrieval of the grafts for histological analysis. Renal function, renal microcirculation and tissue injury including the proliferative response of tubular epithelial cells (TECs) were compared. Results: Preservation using AD-PS or CS-PS resulted in higher microcirculatory flow compared with CS-UW. Improved recovery of renal function was seen in the AD-PS and CS-PS groups compared with CS-UW. Structural integrity was better preserved using AD-PS compared with both CS groups. Proliferative response of TECs was higher in CS-UW preserved grafts compared to grafts preserved using AD-PS. Conclusion: This study demonstrates the biological safety of the AD system in a porcine autotransplantation model. Also, the microcirculation was better preserved and less morphological injury was observed after 20 hr MP compared with CS. (Int J Artif Organs 2009; 32: 728-38)
引用
收藏
页码:728 / 738
页数:11
相关论文
共 50 条
[31]   Extended hypothermic oxygenated machine perfusion enables ex situ preservation of porcine livers for up to 24 hours [J].
Bruggenwirth, Isabel M. A. ;
van Leeuwen, Otto B. ;
de Vries, Yvonne ;
Bodewes, Silke B. ;
Adelmeijer, Jelle ;
Wiersema-Buist, Janneke ;
Lisman, Ton ;
Martins, Paulo N. ;
de Meijer, Vincent E. ;
Porte, Robert J. .
JHEP REPORTS, 2020, 2 (02)
[32]   Can hypothermic oxygenated perfusion (HOPE) rescue futile DCD liver grafts? [J].
Muller, X. ;
Schlegel, A. ;
Wurdinger, M. ;
Wendt, M. ;
Kron, P. ;
Eshmuminov, D. ;
Mullhaupt, B. ;
Clavien, P. A. ;
Dutkowski, P. .
HPB, 2019, 21 (09) :1156-1165
[33]   Hypothermic oxygenated perfusion protects from mitochondrial injury before liver transplantation [J].
Schlegel, Andrea ;
Muller, Xavier ;
Mueller, Matteo ;
Stepanova, Anna ;
Kron, Philipp ;
de Rougemont, Olivier ;
Muiesan, Paolo ;
Clavien, Pierre-Alain ;
Galkin, Alexander ;
Meierhofer, David ;
Dutkowski, Philipp .
EBIOMEDICINE, 2020, 60
[34]   Full left/full right liver graft ex situ split during hypothermic oxygenated perfusion [J].
Rossignol, Guillaume ;
Muller, Xavier ;
Mohkam, Kayvan ;
Dubois, Remi ;
Lesurtel, Mickael ;
Mabrut, Jean-Yves .
PEDIATRIC TRANSPLANTATION, 2022, 26 (05)
[35]   Hypothermic pulsatile preservation of kidneys from uncontrolled deceased donors after cardiac arrest - a retrospective study [J].
Matillon, Xavier ;
Danjou, Fabrice ;
Petruzzo, Palmina ;
Thaunat, Olivier ;
Rimmele, Thomas ;
Delsuc, Claire ;
Faure, Alexandre ;
Rabeyrin, Maud ;
Yedid, Vannary Meas ;
Hanf, William ;
Morelon, Emmanuel ;
Badet, Lionel ;
Codas, Ricardo .
TRANSPLANT INTERNATIONAL, 2017, 30 (12) :1284-1291
[36]   Hypothermic machine perfusion for liver graft preservation [J].
Amin, Arpit ;
Panayotova, Guergana ;
Guarrera, James V. .
CURRENT OPINION IN ORGAN TRANSPLANTATION, 2022, 27 (02) :98-105
[37]   Hypothermic oxygenated perfusion for a steatotic liver graft [J].
Lai, Quirino ;
Ruberto, Franco ;
Melandro, Fabio ;
Laureiro, Zoe Larghi ;
Rossi, Massimo ;
Mennini, Gianluca .
HEPATOBILIARY & PANCREATIC DISEASES INTERNATIONAL, 2020, 19 (01) :88-90
[38]   One Hour Hypothermic Oxygenated Perfusion (HOPE) Protects Nonviable Liver Allografts Donated After Cardiac Death [J].
de Rougemont, Olivier ;
Breitenstein, Stefan ;
Leskosek, Boris ;
Weber, Achim ;
Graf, Rolf ;
Clavien, Pierre-Alain ;
Dutkowski, Philipp .
ANNALS OF SURGERY, 2009, 250 (05) :674-683
[39]   Hypothermic Oxygenated Perfusion: A Simple and Effective Method to Modulate the Immune Response in Kidney Transplantation [J].
Kron, Philipp ;
Schlegel, Andrea ;
Muller, Xavier ;
Gaspert, Ariana ;
Clavien, Pierre-Alain ;
Dutkowski, Philipp .
TRANSPLANTATION, 2019, 103 (05) :E128-E136
[40]   Real-Time Biomarkers of Liver Graft Quality in Hypothermic Oxygenated Machine Perfusion [J].
Zhylko, Andriy ;
Morawski, Marcin ;
Rykowski, Pawel ;
Krasnodebski, Maciej ;
Wyporski, Anya ;
Borkowski, Jan ;
Zhylko, Dmytro ;
Kobryn, Konrad ;
Stankiewicz, Rafal ;
Stypulkowski, Jan ;
Holowko, Waclaw ;
Patkowski, Waldemar ;
Wroblewski, Tadeusz ;
Szczepankiewicz, Benedykt ;
Gornicka, Barbara ;
Mielczarek-Puta, Magdalena ;
Struga, Marta ;
Krawczyk, Marek ;
Grat, Michal .
JOURNAL OF CLINICAL MEDICINE, 2025, 14 (02)