Critical implementation issues of excitation signals for embedded wearable bioimpedance spectroscopy systems with limited resources

被引:24
作者
Kallel, A. Y. [1 ]
Bouchaala, D. [2 ]
Kanoun, O. [1 ]
机构
[1] Tech Univ Chemnitz, Chair Measurement & Sensor Technol, Chemnitz, Germany
[2] Natl Engn Sch Sfax, Digital Res Ctr Sfax, Sfax, Tunisia
关键词
bioimpedance spectroscopy; excitation signal; spectral energy efficiency; crest factor; embedded systems; real implementation; timer; FACTOR MINIMIZATION; TIME;
D O I
10.1088/1361-6501/abf78e
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Wideband excitation signals are essential in bioimpedance spectroscopy for measurements in a time ensuring a quasi-stable measurement condition. In particular, for wearable biomedical systems, due to limited system resources, several aspects regarding measurement time, crest factor, slew rate requirements, frequency distribution, amplitude spectrum, and energy efficiency need to be thoroughly investigated. In this paper, we present an investigation of excitation signals, which includes not only the theoretical aspects but also aspects of real implementation on microcontroller-based systems. At a fixed number of samples and sampling rate, we investigate the implementability of signal frequencies and the resulting spectral efficiency. We focus on sources of signal distortion due to timer and amplitude deviations. The results show that for 4096 samples and a sampling frequency of 1 MHz, wideband signals are 2.76 times faster than a stepped frequency sweep. The multisine signal provides a better energy efficiency and has a lower slew rate requirement on hardware (around 0.3 V mu s(-1)), but has a relatively high crest factor, even after optimization. An exemplary investigation of the distortion of the time/frequency and amplitudes following implementation on a standard industrial advanced RISC machines microcontroller has shown that a sampling rate compensation is required to overcome timer inaccuracies. Furthermore, non-return-to-zero binary signals are more sensitive to distortion due to hardware-related issues and have a lower signal-to-distortion-and-noise (SINAD) ratio than 24 dB, which is lower than the multisine signal, having a SINAD of 31 dB.
引用
收藏
页数:14
相关论文
共 33 条
  • [11] Robust Longitudinal Ankle Edema Assessment Using Wearable Bioimpedance Spectroscopy
    Mabrouk, Samer
    Hersek, Sinan
    Jeong, Hyeon Ki
    Whittingslow, Daniel
    Ganti, Venu G.
    Wolkoff, Paul
    Inan, Omer T.
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2020, 67 (04) : 1019 - 1029
  • [12] Broadband excitation for short-time impedance spectroscopy
    Min, M.
    Pliquett, U.
    Nacke, T.
    Barthel, A.
    Annus, P.
    Land, R.
    [J]. PHYSIOLOGICAL MEASUREMENT, 2008, 29 (06) : S185 - S192
  • [13] Lock-in measurement of bio-impedance variations
    Min, M
    Märtens, O
    Parve, T
    [J]. MEASUREMENT, 2000, 27 (01) : 21 - 28
  • [14] Performance evaluation of wideband bio-impedance spectroscopy using constant voltage source and constant current source
    Mohamadou, Youssoufa
    Oh, Tong In
    Wi, Hun
    Sohal, Harsh
    Farooq, Adnan
    Woo, Eung Je
    McEwan, Alistair Lee
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2012, 23 (10)
  • [15] Ojarand J., 2012, MEMEA 12 P IEEE 7 IN, P1
  • [16] Multichannel Electrical Impedance Spectroscopy Analyzer with Microfluidic Sensors
    Ojarand, Jaan
    Min, Mart
    Koel, Ants
    [J]. SENSORS, 2019, 19 (08):
  • [17] THRESHOLD SELECTION METHOD FROM GRAY-LEVEL HISTOGRAMS
    OTSU, N
    [J]. IEEE TRANSACTIONS ON SYSTEMS MAN AND CYBERNETICS, 1979, 9 (01): : 62 - 66
  • [18] Paavle T., 2012, Fourier Transform-Signal Processing
  • [19] Palme F, 1998, TECH MESS, V65, P370
  • [20] Analytical Model for Blood Glucose Detection Using Electrical Impedance Spectroscopy
    Pedro, Bruna Gabriela
    Cordeiro Marcondes, David William
    Bertemes-Filho, Pedro
    [J]. SENSORS, 2020, 20 (23) : 1 - 11