Similar outcomes with manual contact force ablation catheters and traditional catheters in the treatment of outflow tract premature ventricular complexes

被引:9
作者
Abraham, Pal [1 ]
Ambrus, Mercedesz [1 ]
Herczeg, Szilvia [1 ]
Szegedi, Nandor [1 ]
Nagy, Klaudia Vivien [1 ]
Sallo, Zoltan [1 ]
Osztheimer, Istvan [1 ]
Szeplaki, Gabor [1 ]
Tahin, Tamas [1 ]
Merkely, Bela [1 ]
Geller, Laszlo [1 ]
机构
[1] Semmelweis Univ, Dept Cardiol, Heart & Vasc Ctr, Varosmajor St 68, H-1122 Budapest, Hungary
来源
EUROPACE | 2021年 / 23卷 / 04期
关键词
Contact force; Premature ventricular complexes; Catheter ablation; Outflow tract; Follow-up; RADIOFREQUENCY ABLATION; ATRIAL-FIBRILLATION;
D O I
10.1093/europace/euaa393
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Unlike in atrial fibrillation ablation, there is a lack of appropriately sized and properly designed studies regarding outflow tract (OT) premature ventricular complex (PVC) ablation outcomes with contact force sensing (CFS) catheters. We aimed to compare the acute success-, complication-, and long-term recurrence rates of manual CFS catheters with traditional irrigated catheters (T) in OT PVC ablation. Methods and results Single-centre, propensity-matched data of 75-75 patients ablated for right-sided OT (RVOT) or left-sided OT (LVOT) PVCs in 2015-17 with CFS or T catheters were compared. Acute success rate, peri-procedural complications, post-procedural daily PVC burden, and long-term recurrence rates were compared on intention-to-treat basis. Acute success rate equalled 80% in both groups, with no difference in force values in the CFS group comparing successful or failed cases [12.0 (8.75-17.0) vs. 16.0 (10.25-22.25) g, P = 0.21]. There were three cases of pseudoaneurysm and one cardiac tamponade. PVC burden fell significantly from baseline 22 (15-30)% to 2 (0-10)% (P < 0.0001), with no difference between catheter types [CFS: 1 (0-7)% vs. T: 4 (1-12) %; P = 0.21]. There was no significant difference in recurrence-free survival of CFS and T catheters (58 vs. 59%, P = 0.29) during 12 months of follow-up, respectively. Recurrence in the CFS group did not differ either by the force exerted below or above the median value of 12 g (P = 0.66). Conclusion Both types of catheters can effectively reduce OT PVC burden with minimal serious complication rates. Ablation with CFS or T catheters gives similar acute-and long-term results.
引用
收藏
页码:596 / 602
页数:7
相关论文
共 18 条
  • [1] Use of contact force sensing technology during radiofrequency ablation reduces recurrence of atrial fibrillation: A systematic review and meta-analysis
    Afzal, Muhammad R.
    Chatta, Jawaria
    Samanta, Anweshan
    Waheed, Salman
    Mahmoudi, Morteza
    Vukas, Rachel
    Gunda, Sampath
    Reddy, Madhu
    Dawn, Buddhadeb
    Lakkireddy, Dhanunjaya
    [J]. HEART RHYTHM, 2015, 12 (09) : 1990 - 1996
  • [2] A prospective study on safety of catheter ablation procedures: Contact force guided ablation could reduce the risk of cardiac perforation
    Akca, Ferdi
    Janse, Petter
    Theuns, Dominic A. M. J.
    Szili-Torok, Tamas
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2015, 179 : 441 - 448
  • [3] Mortality and morbidity reduction after frequent premature ventricular complexes ablation in patients with left ventricular systolic dysfunction
    Berruezo, Antonio
    Penela, Diego
    Jauregui, Beatriz
    Soto-Iglesias, David
    Aguinaga, Luis
    Ordonez, Augusto
    Fernandez-Armenta, Juan
    Martinez, Mikel
    Tercedor, Luis
    Bisbal, Felipe
    Acosta, Juan
    Marti-Almor, Julio
    Acena, Marta
    Anguera, Ignasi
    Rossi, Luca
    Linhart, Markus
    Borras, Roger
    Doltra, Adelina
    Sanchez, Paula
    Ortiz-Perez, Jose T.
    Perea, Rosario J.
    Prat-Gonzalez, Susana
    Teres, Cheryl
    Bosch, Xavier
    [J]. EUROPACE, 2019, 21 (07): : 1079 - 1087
  • [4] Acute and one year outcome of premature ventricular contraction ablation guided by contact force and automated pacemapping software
    Capulzini, Lucio
    Vergara, Pasquale
    Mugnai, Giacomo
    Salghetti, Francesca
    Pablo Abugattas, Juan
    El Bouchaibi, Said
    Iacopino, Saverio
    Sieira, Juan
    Enriquez Coutino, Hugo
    Stroeker, Erwin
    Brugada, Pedro
    Chierchia, Gianbattista
    de Asmundis, Carlo
    [J]. JOURNAL OF ARRHYTHMIA, 2019, 35 (03) : 542 - 549
  • [5] Contact force sensing for ablation of persistent atrial fibrillation: A randomized, multicenter trial
    Conti, Sergio
    Weerasooriya, Rukshen
    Novak, Paul
    Champagne, Jean
    Lim, Hong Euy
    Macle, Laurent
    Khaykin, Yaariv
    Pantano, Alfredo
    Verma, Atul
    [J]. HEART RHYTHM, 2018, 15 (02) : 201 - 208
  • [6] Procedural and long-term outcome after catheter ablation of idiopathic outflow tract ventricular arrhythmias: comparing manual, contact force, and magnetic navigated ablation
    de Vries, Lennart J.
    Hendriks, Astrid A.
    Yap, Sing C.
    Theuns, Dominic A. M. J.
    van Domburg, Ron T.
    Szili-Torok, Tamas
    [J]. EUROPACE, 2018, 20 : 22 - 27
  • [7] Safety and Clinical Outcome of Catheter Ablation of Ventricular Arrhythmias Using Contact Force Sensing: Consecutive Case Series
    Hendriks, Astrid Armanda
    Akca, Ferdi
    Abkenari, Lara Dabiri
    Khan, Muchtiar
    Bhagwandien, Rohit
    Yap, Sing-Chien
    Wijchers, Sip
    Szili-Torok, Tamas
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2015, 26 (11) : 1224 - 1229
  • [8] Electrocardiographic predictors of long-term outcomes after radiofrequency ablation in patients with right-ventricular outflow tract tachycardia
    Krittayaphong, Rungroj
    Sriratanasathavorn, Charn
    Dumavibhat, Chatkanok
    Pumprueg, Sachana
    Boonyapisit, Warangkana
    Pooranawattanakul, Sukanya
    Phrudprisan, Suteera
    Kangkagate, Charuwan
    [J]. EUROPACE, 2006, 8 (08): : 601 - 606
  • [9] Contact Force Monitoring for Cardiac Mapping in Patients with Ventricular Tachycardia
    Mizuno, Hiroya
    Vergara, Pasquale
    Maccabelli, Giuseppe
    Trevisi, Nicola
    Colombo, Sebastiano
    Brombin, Chiara
    Mazzone, Patrizio
    Della Bella, Paolo
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2013, 24 (05) : 519 - 524
  • [10] Contact feedback improves 1-year outcomes of remote magnetic navigation-guided ischemic ventricular tachycardia ablation
    Noten, Anna Maria Elisabeth
    Hendriks, Astrid Armanda
    Yap, Sing-Chien
    Mol, Daniel
    Bhagwandien, Rohit
    Wijchers, Sip
    Kardys, Isabella
    Khan, Muchtiar
    Szili-Torok, Tamas
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2020, 315 : 36 - 44