Comparison between a computational seated human model and experimental verification data

被引:1
作者
Olesen, Christian G. [1 ]
de Zee, Mark [2 ]
Rasmussen, John [1 ]
机构
[1] Aalborg Univ, Dept Mech & Mfg Engn, Aalborg, Denmark
[2] Aalborg Univ, Dept Hlth Sci & Technol, Aalborg, Denmark
关键词
Wheelchair; musculoskeletal model; pressure ulcer; validation; chair reaction forces; PRESSURE; INDIVIDUALS; STRESS; INJURY; SHEAR;
D O I
10.1155/2014/126736
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Sitting-acquired deep tissue injuries (SADTI) are the most serious type of pressure ulcers. In order to investigate the aetiology of SADTI a new approach is under development: a musculo-skeletal model which can predict forces between the chair and the human body at different seated postures. This study focuses on comparing results from a model developed in the AnyBody Modeling System, with data collected from an experimental setup. A chair with force-measuring equipment was developed, an experiment was conducted with three subjects, and the experimental results were compared with the predictions of the computational model. The results show that the model predicted the reaction forces for different chair postures well. The correlation coefficients of how well the experiment and model correlate for the seat angle, backrest angle and footrest height was 0.93, 0.96, and 0.95. The study show a good agreement between experimental data and model prediction of forces between a human body and a chair. The model can in the future be used in designing wheelchairs or automotive seats.
引用
收藏
页码:175 / 183
页数:9
相关论文
共 27 条
  • [1] Agam L, 2007, J Wound Care, V16, P336
  • [2] Bader D., 2005, PRESSURE ULCER RES C, P382
  • [3] BENNETT L, 1984, ARCH PHYS MED REHAB, V65, P186
  • [4] A comparison of four office chairs using biomechanical measures
    Bush, Tamara Reid
    Hubbard, Robert R.
    [J]. HUMAN FACTORS, 2008, 50 (04) : 629 - 642
  • [5] Support force measures of midsized men in seated positions
    Bush, Tamara Reid
    Hubbard, Robert P.
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2007, 129 (01): : 58 - 65
  • [6] Medical complications during acute rehabilitation following spinal cord injury - Current experience of the model systems
    Chen, D
    Apple, DF
    Hudson, LM
    Bode, R
    [J]. ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1999, 80 (11): : 1397 - 1401
  • [7] Impact of sitting time on seat-interface pressure and on pressure mapping with multiple sclerosis patients
    Crawford, SA
    Stinson, MD
    Walsh, DM
    Porter-Armstrong, AP
    [J]. ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2005, 86 (06): : 1221 - 1225
  • [8] Dahlquist J., 2004, 2 NORD SEAT S
  • [9] Analysis of musculoskeletal systems in the AnyBody Modeling System
    Damsgaard, Michael
    Rasmussen, John
    Christensen, Soren Torholm
    Surma, Egidijus
    de Zee, Mark
    [J]. SIMULATION MODELLING PRACTICE AND THEORY, 2006, 14 (08) : 1100 - 1111
  • [10] In vivo muscle stiffening under bone compression promotes deep pressure sores
    Gefen, A
    Gefen, N
    Linder-Ganz, E
    Margulies, SS
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2005, 127 (03): : 512 - 524