A three-dimensional finite element model of the polymerization process in dental restorations

被引:54
作者
Barink, M
Van der Mark, PCP
Fennis, WMM
Kuijs, RH
Kreulen, CM
Verdonschot, N
机构
[1] Univ Nijmegen, Ctr Med, Orthopaed Res Lab, NL-6500 HB Nijmegen, Netherlands
[2] Univ Nijmegen, Coll Dent Sci, Dept Oral Funct & Prosthet Dent, NL-6500 HB Nijmegen, Netherlands
[3] Univ Nijmegen, Coll Dent Sci, Dept Prevent & Curat Dent, NL-6500 HB Nijmegen, Netherlands
关键词
D O I
10.1016/S0142-9612(02)00529-X
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Restoration of dental restorations with resin composite is hampered by shrinkage of the material during the polymerization process. In this study, we simulated the polymerization process in a detailed three-dimensional finite element model of a human upper premolar with a cusp-replacing restoration. It was analyzed how the stress patterns changed during polymerization and it was assessed whether immediate failure of the restoration is likely to occur and if so, which locations within the restoration are at highest risk and what the clinical implications of these findings are for clinical practice. It was found that the stresses increased rapidly during polymerization and decreased again in the post-polymerization phase. At the interface, tensile stresses relaxed to a higher degree than the shear stresses. Stress values in the composite material and at the interface with the tooth tissue were lower than the reported strength values suggesting that immediate failure is unlikely. The safety factor against mechanical failure of the interface, however, was relatively low indicating that the interface between the composite material and the tooth tissue is at a higher risk for failure than the bulk of the restoration. Stress relaxation was less effective in areas where the interface surface was irregular. In common practice, irregular interface surfaces are used to increase the retention of the restoration. This study indicates that the increased retention may be compromized to some extent by higher shrinkage stresses. The fact that stresses considerably decreased during the post-polymerization period suggests that mechanical loading should be limited during the first few hours after restoration. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1427 / 1435
页数:9
相关论文
共 17 条
[1]   POISSONS RATIO OF GLASS-POLYALKENOATE (GLASS-IONOMER) CEMENTS DETERMINED BY AN ULTRASONIC PULSE METHOD [J].
AKINMADE, AO ;
NICHOLSON, JW .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1995, 6 (08) :483-485
[2]  
al-Salehi S K, 1997, Quintessence Int, V28, P717
[3]  
BARKMEIER WW, 1992, OPER DENT, P50
[4]   THE COMPETITION BETWEEN THE COMPOSITE-DENTIN BOND STRENGTH AND THE POLYMERIZATION CONTRACTION STRESS [J].
DAVIDSON, CL ;
DEGEE, AJ ;
FEILZER, A .
JOURNAL OF DENTAL RESEARCH, 1984, 63 (12) :1396-1399
[5]  
Eldiwany M, 1993, Am J Dent, V6, P222
[6]   SETTING STRESS IN COMPOSITE RESIN IN RELATION TO CONFIGURATION OF THE RESTORATION [J].
FEILZER, AJ ;
DEGEE, AJ ;
DAVIDSON, CL .
JOURNAL OF DENTAL RESEARCH, 1987, 66 (11) :1636-1639
[7]  
FENNIS WMM, IN PRESS INT J PROST
[8]  
Hubsch P. F., 1999, Comput Methods Biomech Biomed Engin, V2, P245, DOI 10.1080/10255849908907990
[9]   A finite element analysis of the stress at the restoration-tooth interface, comparing inlays and bulk fillings [J].
Hübsch, PF ;
Middleton, J ;
Knox, J .
BIOMATERIALS, 2000, 21 (10) :1015-1019
[10]  
HUBSCH PF, 1995, THESIS U WALES SWANS