Three-dimensional trajectory assessment of an IVUS transducer from single-plane cineangiograms: A phantom study

被引:3
|
作者
Sherknies, D [1 ]
Meunier, J
Mongrain, R
Tardif, JC
机构
[1] Univ Montreal, Dept Comp Sci & Operat Res, Montreal, PQ H3T 1J4, Canada
[2] Montreal Heart Inst, Montreal, PQ H1T 1C8, Canada
关键词
IVUS; phantom; single-plane angiography; 3-D reconstruction;
D O I
10.1109/TBME.2004.843295
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The recovery of the three-dimensional (3-D) path of the transducer used during an intravascular ultrasound (IVUS) examination is of primary importance to assess the exact 3-D shape of the vessel under study Traditionally, the reconstruction is done by simply stacking the images during the pullback, or more recently using biplane angiography to recover the vessel curvature. In this paper, we explain, how single-plane angiography can be used with two projection models, to perform this task. Two types of projection geometry are analyzed: weak-perspective and full-perspective. In weak-perspective projection geometry, the catheter path can be reconstructed without prior transducer depth information. With full-perspective projection geometry, precise depth location of reference points are needed in order to minimize the error of the recovered transducer angle of incidence. The transducer angulation reconstruction is based on the foreshortening effect as seen from the X-ray images. By comparing the measured to the true transducer length, we are able to get its incidence angle. The transducer trajectory is reconstructed by stitching together the different estimated angulations obtained from each image in a cineangiogram sequence. The method is described and validated on two helical vessel phantoms, giving on average a reconstructed path that is less than 2 mm distant from the true path when using full-perspective projection.
引用
收藏
页码:543 / 549
页数:7
相关论文
共 50 条
  • [1] 3D trajectory assessment of an IVUS transducer from single-plane cineangiograms: a phantom study
    Sherknies, D
    Meunier, J
    Tardif, JC
    Mongrain, R
    PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 : 690 - 693
  • [2] REGIONAL MYOCARDIAL DYNAMICS FROM SINGLE-PLANE CORONARY CINEANGIOGRAMS
    DAUGHTERS, GT
    INGELS, NB
    CARRERA, CJ
    JOURNAL OF BIOMECHANICS, 1973, 6 (01) : 25 - +
  • [3] 3D path recovery of an IVUS transducer with single-plane angiography
    Sherknies, D
    Meunier, J
    Tardif, JC
    CCECE 2003: CANADIAN CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING, VOLS 1-3, PROCEEDINGS: TOWARD A CARING AND HUMANE TECHNOLOGY, 2003, : 1489 - 1492
  • [4] A robust 3-D IVUS transducer tracking using single-plane cineangiography
    Jourdain, Melissa
    Meunier, Jean
    Sequeira, Jean
    Boi, Jean-Marc
    Tardif, Jean-Claude
    IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2008, 12 (03): : 307 - 314
  • [5] Determining Three-Dimensional Catheter Location Using Single-Plane Fluoroscopy Only
    Sra, Jasbir
    Belanger, Barry
    Palma, Mark
    Krum, David
    CIRCULATION, 2013, 128 (22)
  • [6] Registration of three-dimensional cardiac catheter models to single-plane fluoroscopic images
    Meyer, SA
    Wolf, PD
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1999, 46 (12) : 1471 - 1479
  • [7] Three-dimensional in vivo motion analysis of normal knees using single-plane fluoroscopy
    Tanifuji, Osamu
    Sato, Takashi
    Kobayashi, Koichi
    Mochizuki, Tomoharu
    Koga, Yoshio
    Yamagiwa, Hiroshi
    Omori, Go
    Endo, Naoto
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2011, 16 (06) : 710 - 718
  • [8] A method for measuring three-dimensional mandibular kinematics in vivo using single-plane fluoroscopy
    Chen, C-C
    Lin, C-C
    Chen, Y-J
    Hong, S-W
    Lu, T-W
    DENTOMAXILLOFACIAL RADIOLOGY, 2013, 42 (01)
  • [9] Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy
    Banks, SA
    Hodge, WA
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1996, 43 (06) : 638 - 649
  • [10] Tendon Phantom Mechanical Properties Assessment by Supersonic Shear Imaging with Three-Dimensional Transducer
    Martins, V. C.
    Rolando, G. B. G.
    De Matheo, L. L.
    Pereira, W. C. A.
    Oliveira, L. F.
    XXVII BRAZILIAN CONGRESS ON BIOMEDICAL ENGINEERING, CBEB 2020, 2022, : 207 - 211