Digital rock physics and application of high-resolution micro-CT techniques for geomaterials

被引:0
作者
Mahanta, Bankim [1 ,2 ,3 ]
Ranjith, P. G. [1 ]
Singh, T. N. [2 ]
Vishal, Vikram [1 ,2 ]
Duan, WenHui [1 ]
Sazid, Mohammed [4 ]
机构
[1] Monash Univ, Dept Civil Engn, Melbourne, Vic, Australia
[2] Indian Inst Technol, Dept Earth Sci, Mumbai, Maharashtra, India
[3] Indian Inst Technol, IITB Monash Res Acad, Mumbai, Maharashtra, India
[4] King Abdulaziz Univ, Min Engn Dept, Fac Engn, Jeddah, Saudi Arabia
来源
DEEP ROCK MECHANICS: FROM RESEARCH TO ENGINEERING | 2019年
关键词
Micro-CT; Sandstone; Pore Network Modelling; Pore; Throat; POROUS-MEDIA; PORE-SPACE; TOMOGRAPHIC-IMAGES;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Understanding the behaviour of rocks at microstructural levels is important for interpreting their macroscopic behaviour and the long-term successful implementation of their engineering applications like underground coal gasification, geothermal energy extractions, enhanced oil recovery, geological carbon sequestrations etc. Digital Rock Physics (DRP) is an alternative way for optimization and measurement of various image-based rock properties like porosity, permeability, electrical conductivity and elastic modulus and has been useful due to its high-resolution insight into the complex rock structure. DRP using micro-CT techniques includes image acquisition, image processing followed by the numerical experiments by means of the field equations and their solutions. The foremost microscopic attributes of rocks are pore volume, pore radius; pore coordination number, throat radius and throat channel length and these can be quantified precisely with the application of micro-CT technique. Additionally, pore-network model and flow behaviour simulation can also be achieved using this technique. In the current study, the advancement and usefulness of micro-CT techniques for geomaterials like rocks is discussed and summarised. Further, the technique is applied to an Indian sandstone to evaluate the above-mentioned rock properties.
引用
收藏
页码:299 / 307
页数:9
相关论文
共 50 条
[31]   Automatic registration and fusion of high resolution micro-CT and lung perfusion SPECT images of the rat [J].
Fei, BW ;
Wietholt, C ;
Clough, AV ;
Dawson, CA ;
Wilson, DL .
PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 :592-594
[32]   Improving Spatial-Resolution in High Cone-Angle Micro-CT by Source Deblurring [J].
Li, Heyang ;
Kingston, Andrew ;
Myers, Glenn ;
Recur, Benoit ;
Turner, Michael ;
Sheppard, Adrian .
DEVELOPMENTS IN X-RAY TOMOGRAPHY IX, 2014, 9212
[33]   Comparison of high-resolution X-ray and micro-CT for experimental evaluation of intracranial stent prototypes: quality evaluation beyond CE mark [J].
Keuler, Andreas ;
Taschner, Christian ;
Brockmann, Marc Alexander ;
Boll, Hanne ;
Foerster, Katharina ;
Lutz, Lisa ;
Herrmann-Frank, Annegret ;
Lelgemann, Monika ;
Schumacher, Martin .
NEURORADIOLOGY, 2014, 56 (04) :315-323
[34]   Comparison of high-resolution X-ray and micro-CT for experimental evaluation of intracranial stent prototypes: quality evaluation beyond CE mark [J].
Andreas Keuler ;
Christian Taschner ;
Marc Alexander Brockmann ;
Hanne Boll ;
Katharina Förster ;
Lisa Lutz ;
Annegret Herrmann-Frank ;
Monika Lelgemann ;
Martin Schumacher .
Neuroradiology, 2014, 56 :315-323
[35]   Analysis of wood anatomy via high-resolution micro-MRI and micro-CT: first approaches and results from Pozzo di Bellafonte (Montaione, Florence, Italy) [J].
de Loewenstern, Antonio Borzatti ;
Giovannetti, Giulio ;
Panetta, Daniele ;
Flori, Alessandra ;
Francischello, Roberto ;
Alderighi, Lorella .
PLANT BIOSYSTEMS, 2024, 158 (06) :1358-1363
[36]   High-resolution ex vivo imaging in mouse spinal cord using micro-CT with 11.7T-MRI and myelin staining validation [J].
Saito, Shigeyoshi ;
Mori, Yuki ;
Yoshioka, Yoshichika ;
Murase, Kenya .
NEUROSCIENCE RESEARCH, 2012, 73 (04) :337-340
[37]   Accurate Resolution Measurement for X-Ray Micro-CT Systems [J].
Sen Sharma, K. ;
Seshadri, S. ;
Feser, M. ;
Wang, G. .
10TH INTERNATIONAL CONFERENCE ON X-RAY MICROSCOPY, 2011, 1365 :337-340
[38]   Optimizing Micro-CT Resolution for Geothermal Reservoir Characterization in the Pannonian Basin [J].
Njeru, Rita Mwendia ;
Sofyan, Akhmad ;
Halisch, Matthias ;
Kobor, Balazs ;
Szanyi, Janos .
ENERGIES, 2024, 17 (13)
[39]   Application of the Flower Pollination Algorithm in the Analysis of Micro-CT Scans [J].
Kowalski, Piotr A. ;
Kaminski, Jakub ;
Lukasik, Szymon ;
Swiebocka-Wiek, Joanna ;
Golunaka, Dominika ;
Tarasiuk, Jacek ;
Kulczycki, Piotr .
TRENDS IN MATHEMATICS AND COMPUTATIONAL INTELLIGENCE, 2019, 796 :1-9
[40]   Digital preservation and dissemination of ancient lithic technology with modern micro-CT [J].
Abel, R. L. ;
Parfitt, S. ;
Ashton, N. ;
Lewis, Simon G. ;
Scott, Beccy ;
Stringer, C. .
COMPUTERS & GRAPHICS-UK, 2011, 35 (04) :878-884