Evaluation of serum protein profiling by surface-enhanced laser desorption/ionization time-of-flight mass spectrometry for the detection of prostate cancer: I. Assessment of platform reproducibility

被引:272
|
作者
Semmes, OJ
Feng, Z
Adam, BL
Banez, LL
Bigbee, WL
Campos, D
Cazares, LH
Chan, DW
Grizzle, WE
Izbicka, E
Kagan, J
Malik, G
McLerran, D
Moul, JW
Partin, A
Prasanna, P
Rosenzweig, J
Sokoll, LJ
Srivastava, S
Srivastava, S
Thompson, I
Welsh, MJ
White, N
Winget, M
Yasui, Y
Zhang, Z
Zhu, L
机构
[1] Eastern Virginia Med Sch, Dept Microbiol & Mol Cell Biol, Virginia Prostate Ctr, Norfolk, VA 23507 USA
[2] Fred Hutchinson Canc Res Ctr, Seattle, WA 98104 USA
[3] Uniformed Serv Univ Hlth Sci, Ctr Prostate Dis Res, Dept Surg, Rockville, MD USA
[4] Univ Pittsburgh, Inst Canc, Hillman Canc Ctr, Pittsburgh, PA USA
[5] Inst Drug Dev, Canc Therapy & Res Ctr, San Antonio, TX USA
[6] Johns Hopkins Med Inst, Dept Pathol, Baltimore, MD 21205 USA
[7] Univ Alabama Birmingham, Dept Pathol, Birmingham, AL 35294 USA
[8] Natl Canc Inst, Div Canc Prevent, Canc Biomakers Res Grp, Bethesda, MD USA
[9] Univ Texas, Hlth Sci Ctr, Dept Med, San Antonio, TX 78284 USA
关键词
D O I
10.1373/clinchem.2004.038950
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Protein expression profiling for differences indicative of early cancer has promise for improving diagnostics. This report describes the first stage of a National Cancer Institute/Early Detection Research Network-sponsored multiinstitutional evaluation and validation of this approach for detection of prostate cancer. Methods: Two sequential experimental phases were conducted to establish interlaboratory calibration and standardization of the surf ace-enhanced laser desorption (SELDI) instrumental and assay platform output. We first established whether the output from multiple calibrated Protein Biosystem II SELDI-ionization time-of-flight mass spectrometry (TOF-MS) instruments demonstrated acceptable interlaboratory reproducibility. This was determined by measuring mass accuracy, resolution, signal-to-noise ratio, and normalized intensity of three m/z "peaks" present in a standard pooled serum sample. We next evaluated the ability of the calibrated and standardized instrumentation to accurately differentiate between selected cases of prostate cancer and control by use of an algorithm developed from data derived from a single site 2 years earlier. Results: When the described standard operating procedures were established at all laboratory sites, the across-laboratory measurements revealed a CV for mass accuracy of 0.1%. signal-to-noise ratio of similar to40%, and normalized intensity of 15-36% for the three pooled serum peaks. This was comparable to the intralaboratory measurements of the same peaks. The instrument systems were then challenged with sera from a selected group of 14 cases and 14 controls. The classification agreement between each site and the established decision algorithm were examined by use of both raw peak intensity boosting and ranked peak intensity boosting. All six sites achieved perfect blinded classification for all samples when boosted alignment of raw intensities was used. Four of six sites achieved perfect blinded classification with ranked intensities, with one site passing the criteria of 26 of 28 correct and one site failing with 19 of 28 correct. Conclusions: These results demonstrate that "between-laboratory" reproducibility of SELDI-TOF-MS serum profiling approaches that of "within-laboratory" reproducibility as determined by measuring discrete m/z peaks over time and Across laboratories. (C) 2005 American Association for Clinical Chemistry.
引用
收藏
页码:102 / 112
页数:11
相关论文
共 50 条
  • [1] Detection of breast cancer by surface-enhanced laser desorption/ionization time-of-flight mass spectrometry tissue and serum protein profiling
    Gast, Marie-Christine W.
    van Dulkenz, Eric J.
    van Loenen, Thea K. G.
    Kingma-Vegter, Florine
    Westerga, Johan
    Flohil, Claudie C.
    Knol, Jaco C.
    Jimenez, Connie R.
    van Gils, Carla H.
    Wessels, Lodewijk F. A.
    Schellens, Jan H. M.
    Beijnen, Jos H.
    INTERNATIONAL JOURNAL OF BIOLOGICAL MARKERS, 2009, 24 (03): : 130 - 141
  • [2] Surface-enhanced laser desorption/ionization time-of-flight mass spectrometry: serum protein profiling in seminoma patients
    Romy Strenziok
    Stefan Hinz
    Christian Wolf
    Tim Conrad
    Hans Krause
    Kurt Miller
    Mark Schrader
    World Journal of Urology, 2010, 28 : 193 - 197
  • [3] Surface-enhanced laser desorption/ionization time-of-flight mass spectrometry: serum protein profiling in seminoma patients
    Strenziok, Romy
    Hinz, Stefan
    Wolf, Christian
    Conrad, Tim
    Krause, Hans
    Miller, Kurt
    Schrader, Mark
    WORLD JOURNAL OF UROLOGY, 2010, 28 (02) : 193 - 197
  • [4] Serum Protein Profiling of Cervical Cancer Patients Using Surface-Enhanced Laser Desorption/Ionization Time-of-Flight Mass Spectrometry
    Ye, Nengsheng
    Li, Jian
    ANALYTICAL LETTERS, 2013, 46 (02) : 250 - 257
  • [5] Surface-enhanced laser desorption/ionization time-of-flight mass spectrometry serum protein profiling to identify nasopharyngeal carcinoma
    Ho, David Wing Yuen
    Yang, Zhen Fan
    Wong, Birgitta Yee-Hang
    Kwong, Dora Lai-Wan
    Sham, Jonathan Shun-Tong
    Wei, William Ignace
    Yuen, Anthony Po Wing
    CANCER, 2006, 107 (01) : 99 - 107
  • [6] Urine protein profiling with surface-enhanced laser-desorption/ionization time-of-flight mass spectrometry
    Schaub, S
    Wilkins, J
    Weiler, T
    Sangster, K
    Rush, D
    Nickerson, P
    KIDNEY INTERNATIONAL, 2004, 65 (01) : 323 - 332
  • [7] Identification of lung cancer patients by serum protein profiling using surface-enhanced laser desorption/ionization time-of-flight mass spectrometry
    Han, Ke-qi
    Huang, Guang
    Gao, Chun-fang
    Wang, Xiu-li
    Ma, Bo
    Sun, Liang-qi
    Wei, Zhi-jie
    AMERICAN JOURNAL OF CLINICAL ONCOLOGY-CANCER CLINICAL TRIALS, 2008, 31 (02): : 133 - 139
  • [8] Evaluation of serum diagnosis of pancreatic cancer by using surface-enhanced laser desorption/ionization time-of-flight mass spectrometry
    Gao, Hongjun
    Zheng, Zhaoxu
    Yue, Zhigang
    Liu, Fang
    Zhou, Lanping
    Zhao, Xiaohang
    INTERNATIONAL JOURNAL OF MOLECULAR MEDICINE, 2012, 30 (05) : 1061 - 1068
  • [9] Assessment of protein stability in cerebrospinal fluid using surface-enhanced laser desorption/ionization time-of-flight mass spectrometry protein profiling
    Ranganathan S.
    Polshyna A.
    Nicholl G.
    Lyons-Weiler J.
    Bowser R.
    Clinical Proteomics, 2006, 2 (1-2) : 91 - 102
  • [10] Optimization and evaluation of surface-enhanced laser-desorption/ionization time-of-flight mass spectrometry for protein profiling of cerebrospinal fluid
    Nelson Guerreiro
    Baltazar Gomez-Mancilla
    Stéphane Charmont
    Proteome Science, 4