Effects of bioaerosol polluted outdoor air on airways of residents: a cross sectional study

被引:112
作者
Herr, CEW
zur Nieden, A
Jankofsky, M
Stilianakis, NI
Boedeker, RH
Eikmann, TF
机构
[1] Univ Giessen, Fac Med, Med Ctr, Inst Hyg & Environm Med, D-35385 Giessen, Germany
[2] Commiss European Communities, Joint Res Ctr, I-21020 Ispra, VA, Italy
[3] Univ Giessen, Fac Med, Med Ctr, Inst Stat & Informat, D-35390 Giessen, Germany
关键词
D O I
10.1136/oem.60.5.336
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background: Bioaerosol pollution of workplace and home environments mainly affects airways and mucous membranes. The effect of environmental outdoor residential bioaerosol pollution, for example, livestock holdings, farming, and waste disposal plants, is unclear. Aims: To investigate the perceived health of residents living in areas with measurable outdoor bioaerosol pollution (for example, spores of Aspergillus fumigatus and actinomycetes), and effects of accompanying odours. Methods: In a cross sectional study, double blinded to ongoing microbial measurements, doctors collected 356 questionnaires from residents near a large scale composting site, and from unexposed controls in 1997. Self reported prevalence of health complaints during the past year, doctors' diagnoses, as well as residential odour annoyance were assessed. Microbiological pollution was measured simultaneously in residential outdoor air. Results: Concentrations of >10(5) colony forming units of thermophilic actinomycetes, moulds, and total bacteria/m(3) air were measured 200 m from the site, dropping to near background concentrations within 300 m. Positive adjusted associations were observed for residency within 150-200 m from the site versus unexposed controls for self reported health complaints: "waking up due to coughing", odds ratio (OR) 6.59 (95% confidence interval (CI) 2.57 to 17.73); "coughing on rising or during the day", OR 3.18 (95% CI 1.24 to 8.36); "bronchitis", OR 3.59 (95% CI 1.40 to 9.4); and "excessive tiredness", OR 4.27 (95% CI 1.56 to 12.15). Reports of irritative airway complaints were associated with residency in the highest bioaerosol exposure, 150-200 m (versus residency >400-500 m) from the site, and period of residency more than five years, but not residential odour annoyance. Lifetime prevalence of self reported diseases did not differ with exposure. Conclusions: Bioaerosol pollution of residential outdoor air can occur in concentrations found in occupational environments. For the first time residents exposed to bioaerosol pollution were shown to report irritative respiratory complaints similar to mucous membrane irritation independently of perceived odours.
引用
收藏
页码:336 / 342
页数:7
相关论文
共 35 条
[21]   OCCUPATIONAL-HEALTH PROBLEMS DUE TO GARBAGE SORTING [J].
MALMROS, P ;
SIGSGAARD, T ;
BACH, B .
WASTE MANAGEMENT & RESEARCH, 1992, 10 (03) :227-234
[22]  
MILLNER P, 1995, BIOCYCLE, V36, P48
[23]   Effects of damp and mould in the home on respiratory health: a review of the literature [J].
Peat, JK ;
Dickerson, J ;
Li, J .
ALLERGY, 1998, 53 (02) :120-128
[24]   SORTING AND RECYCLING OF DOMESTIC WASTE - REVIEW OF OCCUPATIONAL-HEALTH PROBLEMS AND THEIR POSSIBLE CAUSES [J].
POULSEN, OM ;
BREUM, NO ;
EBBEHOJ, N ;
HANSEN, AM ;
IVENS, UI ;
VANLELIEVELD, D ;
MALMROS, P ;
MATTHIASEN, L ;
NIELSEN, BH ;
NIELSEN, EM ;
SCHIBYE, B ;
SKOV, T ;
STENBAEK, EI ;
WILKINS, KC .
SCIENCE OF THE TOTAL ENVIRONMENT, 1995, 168 (01) :33-56
[25]  
RICHERSON HB, 1990, AM J IND MED, V17, P139
[26]   Introduction and summary: Workshop on children's health and indoor mold exposure [J].
Rylander, R ;
Etzel, R .
ENVIRONMENTAL HEALTH PERSPECTIVES, 1999, 107 :465-468
[27]   (1→3)-β-D-glucan -: relationship to indoor air-related symptoms, allergy and asthma [J].
Rylander, R ;
Lin, RH .
TOXICOLOGY, 2000, 152 (1-3) :47-52
[28]  
Schiffman SS, 1998, J ANIM SCI, V76, P1343
[29]   SYMPTOM PREVALENCE AND ODOR-WORRY INTERACTION NEAR HAZARDOUS-WASTE SITES [J].
SHUSTERMAN, D ;
LIPSCOMB, J ;
NEUTRA, R ;
SATIN, K .
ENVIRONMENTAL HEALTH PERSPECTIVES, 1991, 94 :25-30
[30]  
*STAT NEW YORK DEP, 1994, PROSP STUD HLTH SYMP