An Emergy-based Approach to Evaluate the Effectiveness of Integrating IoT-based Sensing Systems into Smart Buildings

被引:25
作者
Kumar, Tarun [1 ,2 ]
Srinivasan, Ravi [3 ]
Mani, Monto [1 ]
机构
[1] Indian Inst Sci, SuDesi Lab, Ctr Product Design & Mfg, CV Raman Ave, Bengaluru 560012, Karnataka, India
[2] Univ Florida, Sr Sch Construct Management, UrbSys Lab, BHAVANs Fellow, Gainesville, FL 32611 USA
[3] Univ Florida, Sr Sch Construct Management, UrbSys Lab, ME Rinker, Gainesville, FL 32611 USA
关键词
Smart Buildings; Emergy Neutrality; Sensing System; Internet-of-Things; Energy Neutrality; WIRELESS SENSOR NETWORKS; ENVIRONMENTAL PERFORMANCE; SUSTAINABILITY ASSESSMENT; ENERGY SOLUTIONS; GREEN IOT; OPTIMIZATION; ARCHITECTURES; PARAMETERS; INDICATORS; MANAGEMENT;
D O I
10.1016/j.seta.2022.102225
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Wireless Sensing Systems based on the Internet of Things (IoT) are increasingly being deployed in smart buildings to reduce their energy consumption and environmental impacts. However, the actual environmental costs of integrating IoT-based sensing systems into smart buildings have rarely been considered when reporting on their overall sustainability footprint. This paper presents an Emergy-based methodological approach to ascertain the effectiveness of integrating IoT-based sensing systems into smart buildings. The proposed method employs three novel Emergy Neutrality Indices (ENIs): The Sensing System to Building Emergy (SBEm) ratio, the Emergy Neutrality Score (EmN), and the Emergy Payback Time (EmPBT). The Solar House at Gainesville, Florida, retrofitted with an IoT-based sensing system, is used as an example building for computing these indices. A Building Energy Model (BEM) is created using the EnergyPlus (TM) simulation engine available in DesignBuilder V7 to determine the operational Emergy of the building. A custom-built CO2 sensor is used to collect the real-time occupancy data for incorporation into the BEM. The Emergy Neutrality computation demonstrates that the integration of the given sensing system is effective in the Solar House, with SBEm, EmN, and EmPBT values of 2.06E-03, 0.28, and 3.61 years, respectively. By varying the sensors' energy-savings potential and spatiofunctional configurations, nine design scenarios are generated and evaluated for their environmental performance using Emergy ratios and the proposed ENIs. Finally, the Solar House is compared with the Rinker Hall to emphasise the significance of reporting these indices. In the future, designers, architects, and other stakeholders could use these ENIs as useful sustainability assessment tools to evaluate the environmental effectiveness of integrating these smart sensing systems into buildings.
引用
收藏
页数:19
相关论文
共 132 条
[1]  
Abedin SF, 2015, 2015 INTERNATIONAL CONFERENCE ON INFORMATION NETWORKING (ICOIN), P177, DOI 10.1109/ICOIN.2015.7057878
[2]   Hidden costs of a typical embodied energy analysis: Brazilian sugarcane ethanol as a case study [J].
Agostinho, Feni ;
Siche, Raul .
BIOMASS & BIOENERGY, 2014, 71 :69-83
[3]  
Akkaya K, 2015, IEEE WIREL COMMUNN, P58, DOI 10.1109/WCNCW.2015.7122529
[4]   Smart buildings features and key performance indicators: A review [J].
Al Dakheel, Joud ;
Del Pero, Claudio ;
Aste, Niccolo ;
Leonforte, Fabrizio .
SUSTAINABLE CITIES AND SOCIETY, 2020, 61
[5]   Impact of building material recycle or reuse on selected emergy ratios [J].
Amponsah, N. Y. ;
Lacarriere, B. ;
Jamali-Zghal, N. ;
Le Corre, O. .
RESOURCES CONSERVATION AND RECYCLING, 2012, 67 :9-17
[6]   The impact of renovation measures on building environmental performance: An emergy approach [J].
Andric, Ivan ;
Pina, Andre ;
Ferrao, Paulo ;
Lacarriere, Bruno ;
Le Corre, Olivier .
JOURNAL OF CLEANER PRODUCTION, 2017, 162 :776-790
[7]  
[Anonymous], 2010, Energy Performance of Buildings Directive (recast) 2010/31/EU (EPBD)
[8]  
[Anonymous], 2015, U.S. Department of Energy, V3, P1
[9]  
[Anonymous], 1993, OCCUPANCY SENSORS PR
[10]   Green IoT: An Investigation on Energy Saving Practices for 2020 and Beyond [J].
Arshad, Rushan ;
Zahoor, Saman ;
Shah, Munam Ali ;
Wahid, Abdul ;
Yu, Hongnian .
IEEE ACCESS, 2017, 5 :15667-15681