Highly sensitive electrochemical detection of cancer biomarker based on anti-EpCAM conjugated molybdenum disulfide grafted reduced graphene oxide nanohybrid

被引:32
作者
Jalil, Owais [1 ]
Pandey, Chandra Mouli [1 ]
Kumar, Devendra [1 ]
机构
[1] Delhi Technol Univ, Dept Appl Chem, Delhi 110042, India
关键词
Cancer; Biomarkers; Biosensor; EpCAM; Graphene oxide; Molybdenum disulfide; HIGH-PERFORMANCE; MOS2; NANOSHEETS; BIOSENSOR; NANOCOMPOSITE; NANOPARTICLES; IMMUNOSENSOR; CELLS;
D O I
10.1016/j.bioelechem.2020.107733
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
An ultrasensitive, electrochemical biosensor has been fabricated by utilizing molybdenum disulfide (MoS2) grafted reduced graphene oxide (MoS2@rGO) nanohybrid as a sensing platform. Biomolecular-assisted synthetic method was adopted to synthesize MoS2@rGO nanohybrid, where L-cys was used to reduce GO. The MoS2@rGO nanohybrid exhibits improved electrochemical performance when it has been electrophoretically deposited onto the indium tin oxide (ITO) coated glass substrate. Further, epithelial cell adhesion molecule antibodies (anti-EpCAM) specific to cancer biomarker has been covalently immobilized on the MoS2@rGO/ITO electrodes for label-free detection of EpCAM. Electrochemical results confirm that anti-EpCAM/MoS2@rGO/ITO based biosensor can detect EpCAM in the concentration range of 0.001-20 ng mL(-1) with a detection limit of 44.22 fg mL(-1) (S/N = 3). The biosensor's excellent analytical performance has been attributed to the efficient immobilization of EpCAM antibodies on the MoS2@rGO surface, which results in high specificity for EpCAM antigen. The fabricated biosensor showed good selectivity, reproducibility, and stability. The successful detection of EpCAM antigen in spiked samples (human saliva, serum and urine) makes this platform an alternative method for early screening of cancer biomarker. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] A highly selective and sensitive electrochemical sensor for tetracycline resistant genes detection based on the non-covalent interaction of graphene oxide and nucleobase
    Xing, Yi
    Zhang, Yanan
    Zhu, Xiaolin
    Wang, Chengzhi
    Zhang, Tingting
    Cheng, Fangyuan
    Qu, Jiao
    Peijnenburg, Willie J. G. M.
    SCIENCE OF THE TOTAL ENVIRONMENT, 2024, 906
  • [42] Highly sensitive label-free electrochemical aptasensors based on photoresist derived carbon for cancer biomarker detection
    Forouzanfar, Shahrzad
    Alam, Fahmida
    Pala, Nezih
    Wang, Chunlei
    BIOSENSORS & BIOELECTRONICS, 2020, 170
  • [43] Yttrium Functionalized Reduced Graphene Oxide Nanocomposite-Based Aptasensor for Ultrasensitive Detection of a Breast Cancer Biomarker
    Parihar, Arpana
    Khan, Raju
    ACS APPLIED NANO MATERIALS, 2023, 7 (16) : 18207 - 18218
  • [44] An enzyme-free sensor based on La-doped CoFe-layered double hydroxide decorated on reduced graphene oxide for sensitive electrochemical detection of urea
    Khataee, Simin
    Dehghan, Gholamrez
    Shaghaghi, Zohreh
    Khataee, Alireza
    MICROCHIMICA ACTA, 2024, 191 (03)
  • [45] Design of a Sensitive Electrochemical Sensor Based on Ferrocene-Reduced Graphene Oxide/Mn-Spinel for Hydrazine Detection
    Singh, Manorama
    Bhardiya, Smita R.
    Asati, Ambika
    Sheshma, Harendra
    Rai, Ankita
    Rai, Vijai K.
    ELECTROANALYSIS, 2021, 33 (02) : 464 - 472
  • [46] Nanostructured palladium-reduced graphene oxide platform for high sensitive, label free detection of a cancer biomarker
    Kumar, Vinod
    Srivastava, Saurabh
    Umrao, Sima
    Kumar, Ram
    Nath, Gopal
    Sumana, Gajjala
    Saxena, Preeti S.
    Srivastava, Anchal
    RSC ADVANCES, 2014, 4 (05): : 2267 - 2273
  • [47] Highly Sensitive Electrochemical Aptasensor for Detection of Glypican-3 Using Hemin-Reduced Graphene Oxide-Platinum Nanoparticles Coupled with Conductive Reduced Graphene Oxide-Gold Nanoparticles
    Li, Guiyin
    Li, HaiMei
    Chen, Wei
    Chen, Huijiang
    Wu, Guanxiong
    Tan, Mingxiong
    Liang, Jintao
    Zhou, Zhide
    JOURNAL OF BIOMEDICAL NANOTECHNOLOGY, 2021, 17 (12) : 2444 - 2454
  • [48] An Ultra-sensitive Electrochemical Sensor for the Detection of Oxidative Stress Biomarker 3-Nitro-l-tyrosine in Human Blood Serum and Saliva Samples Based on Reduced Graphene Oxide Entrapped Zirconium (IV) Oxide
    Maheshwaran, Selvarasu
    Akilarasan, Muthumariappan
    Chen, Shen-Ming
    Chen, Tse-Wei
    Tamilalagan, Elayappan
    Tzu, Chang Yen
    Lou, Bih-Show
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2020, 167 (06)
  • [49] Highly sensitive electrochemical sensor based on environmentally friendly biomass-derived sulfur-doped graphene for cancer biomarker detection
    Shahzad, Faisal
    Zaidi, Shabi Abbas
    Koo, Chong Min
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 241 : 716 - 724
  • [50] A novel bioconjugated reduced graphene oxide-based nanocomposite for sensitive electrochemical detection of cadmium in water
    Bhardiya, Smita R.
    Asati, Ambika
    Sheshma, Harendra
    Rai, Ankita
    Rai, Vijai K.
    Singh, Manorama
    SENSORS AND ACTUATORS B-CHEMICAL, 2021, 328 (328):