Load sharing properties of cervical pedicle screw-rod constructs versus lateral mass screw-rod constructs

被引:39
作者
Dunlap, Bradley J. [1 ]
Karaikovic, Eldin E. [1 ]
Park, Hyung-Soon [2 ]
Sokolowski, Mark J. [3 ]
Zhang, Li-Qun [2 ]
机构
[1] NorthShore Univ Healthcare Syst, Dept Orthopaed Surg, Evanston, IL 60201 USA
[2] Northwestern Univ, Rehabil Inst Chicago, Chicago, IL 60611 USA
[3] Trinity Orthopaed, Oak Pk, IL USA
关键词
Cervical spine; Biomechanics; Cervical pedicle screws; Lateral mass screws; BIOMECHANICAL ANALYSIS; FIXATION; COMPLICATIONS; SPINE; RECONSTRUCTION; STABILIZATION; PLACEMENT; LESIONS;
D O I
10.1007/s00586-010-1278-0
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Lateral mass screws have a history of successful clinical use, but cannot always be used in the subaxial cervical spine. Despite safety concerns, cervical pedicle screws have been proposed as an alternative. Pedicle screws have been shown to be biomechanically stronger than lateral mass screws. No study, however, has investigated the load sharing properties comparing constructs using these screws. To investigate this, 12 fresh-frozen single cervical spine motion segments (C4-5 and C6-7) from six cadavers were isolated. They were randomized to receive either lateral mass or pedicle screw-rod constructs. After preloading, the segments were cyclically loaded with a uniplanar axial load from 0 to 90 N both with and without the construct in place. Pressure data at the disc space were continuously collected using a dynamic pressure sensor. The reduction in disc space pressure between the two constructs was calculated to see if pedicle screw and lateral mass screw-rod constructs differed in their load sharing properties. In both the pedicle screw and lateral mass screw-rod constructs, there was a significant reduction in the disc space pressures from the no-construct to construct conditions. The percentage decrease for the pedicle screw constructs was significantly greater than the percentage decrease for the lateral mass screw constructs for average pressure (p a parts per thousand currency sign 0.002), peak pressure (p a parts per thousand currency sign 0.03) and force (p a parts per thousand currency sign 0.04). We conclude that cervical pedicle screw-rod constructs demonstrated a greater reduction in axial load transfer through the intervertebral disc than lateral mass screw-rod constructs. Though there are dangers associated with the insertion of cervical pedicle screws, their use might be advantageous in some clinical conditions when increased load sharing is necessary.
引用
收藏
页码:803 / 808
页数:6
相关论文
共 25 条
  • [1] Complications of pedicle screw fixation in reconstructive surgery of the cervical spine
    Abumi, K
    Shono, Y
    Ito, M
    Taneichi, H
    Kotani, Y
    Kaneda, K
    [J]. SPINE, 2000, 25 (08) : 962 - 969
  • [2] One-stage posterior decompression and reconstruction of the cervical spine by using pedicle screw fixation systems
    Abumi, K
    Kaneda, K
    Shono, Y
    Fujiya, M
    [J]. JOURNAL OF NEUROSURGERY, 1999, 90 (01) : 19 - 26
  • [3] TRANSPEDICULAR SCREW FIXATION FOR TRAUMATIC LESIONS OF THE MIDDLE AND LOWER CERVICAL-SPINE - DESCRIPTION OF THE TECHNIQUES AND PRELIMINARY-REPORT
    ABUMI, K
    ITOH, H
    TANEICHI, H
    KANEDA, K
    [J]. JOURNAL OF SPINAL DISORDERS, 1994, 7 (01): : 19 - 28
  • [4] Correction of cervical kyphosis using pedicle screw fixation systems
    Abumi, K
    Shono, Y
    Taneichi, H
    Ito, M
    Kaneda, K
    [J]. SPINE, 1999, 24 (22) : 2389 - 2396
  • [5] ANATOMIC CONSIDERATIONS FOR PLATE-SCREW FIXATION OF THE CERVICAL-SPINE
    AN, HS
    GORDIN, R
    RENNER, K
    [J]. SPINE, 1991, 16 (10) : S548 - S551
  • [6] Flexion failure of posterior cervical lateral mass screws - Influence of insertion technique and position
    Choueka, J
    Spivak, JM
    Kummer, FJ
    Steger, T
    [J]. SPINE, 1996, 21 (04) : 462 - 468
  • [7] POSTERIOR PLATES IN THE MANAGEMENT OF CERVICAL INSTABILITY - LONG-TERM RESULTS IN 44 PATIENTS
    FEHLINGS, MG
    COOPER, PR
    ERRICO, TJ
    [J]. JOURNAL OF NEUROSURGERY, 1994, 81 (03) : 341 - 349
  • [8] Posterior cervical arthrodesis and stabilization with a lateral mass plate - Clinical and computed tomographic evaluation of lateral mass screw placement and associated complications
    Graham, AW
    Swank, ML
    Kinard, RE
    Lowery, GL
    Dials, BE
    [J]. SPINE, 1996, 21 (03) : 323 - 328
  • [9] Biomechanical study of screws in the lateral masses: Variables affecting pull-out resistance
    Heller, JG
    Estes, BT
    Zaouali, M
    Diop, A
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1996, 78A (09) : 1315 - 1321
  • [10] COMPLICATIONS OF POSTERIOR CERVICAL PLATING
    HELLER, JG
    SILCOX, DH
    SUTTERLIN, CE