Influence of Staged-Air on Combustion Characteristics and NOx Emissions of a 300 MWe Down-Fired Boiler with Swirl Burners

被引:35
作者
Li, Zhengqi [1 ]
Fan, Subo [1 ]
Liu, Guangkui [1 ]
Yang, Xuehai [1 ]
Chen, Zhichao [1 ]
Su, Wei [1 ]
Wang, Lin [1 ]
机构
[1] Harbin Inst Technol, Sch Energy Sci & Engn, Harbin 150001, Peoples R China
关键词
TEMPERATURE; FLOW;
D O I
10.1021/ef900476c
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Using an IFA300 constant temperature anemometer system, cold air experiments on a quarter-scaled burner model sited in a 300 MWe down-fired boiler were carried out to investigate the influence of various relative secondary air ratios oil the flow characteristics in the burner nozzle region. With decreasing secondary air ratio, axial velocities and entrained flue gas decreased,, as well as tangential velocities and rates of jet diffusion. However, the more that secondary air obstructs the diffusion of primary air, rates of primary air diffusion increased. Industrial-sized experiments were performed oil a 300 MWe down-fired boiler with swirl burners. Gas temperature, concentrations of gas components (O-2, CO, and NOx) in the burn region and combustible content in the fly ash were measured over a range of staged-air damper openings of 15, 25, and 35%. With openings of 15 and 25%, the level of pulverized-coal burnout is high, although NOx emissions were also it little higher. The level of burnout degree decreased for a 35% opening, and exhaust gas temperatures increased. Although the boiler efficiency decreased, NOx emissions also decreased.
引用
收藏
页码:38 / 45
页数:8
相关论文
共 10 条
[1]  
BURDETT NA, 1987, J I ENERGY, V60, P103
[2]   Measurements of gas species, temperature, and char burnout in a low-NOx pulverized-coal-fired utility boiler [J].
Costa, M ;
Silva, P ;
Azevedo, JLT .
COMBUSTION SCIENCE AND TECHNOLOGY, 2003, 175 (02) :271-289
[3]   NOx emission and thermal efficiency of a 300 MWe utility boiler retrofitted by air staging [J].
Li, Sen ;
Xu, Tongmo ;
Hui, Shien ;
Wei, Xiaolin .
APPLIED ENERGY, 2009, 86 (09) :1797-1803
[4]   Influence of vent air valve opening on combustion characteristics of a down-fired pulverized-coal 300 MWe utility boiler [J].
Li, Zhengqi ;
Ren, Feng ;
Zhang, Jie ;
Zhang, Xiaohui ;
Chen, Zhichao ;
Chen, Lizhe .
FUEL, 2007, 86 (15) :2457-2462
[5]  
MUELLER UR, 1982, FLUID MECH, V119, P155
[6]   Influence of the secondary air-box damper opening on airflow and combustion characteristics of a down-fired 300-MWe utility boiler [J].
Ren, Feng ;
Li, Zhengqi ;
Zhang, Yubin ;
Sun, Shaozeng ;
Zhang, Xiaohui ;
Chen, Zhichao .
ENERGY & FUELS, 2007, 21 (02) :668-676
[7]   Effect of the rotor shape on the mixing characteristics of a continuous flow Taylor-vortex reactor [J].
Richter, Oliver ;
Hoffmann, Heike ;
Kraushaar-Czarnetzki, Bettina .
CHEMICAL ENGINEERING SCIENCE, 2008, 63 (13) :3504-3513
[8]   Local temperature measurements in a full-scale utility boiler with overfire air [J].
Tree, DR ;
Webb, BW .
FUEL, 1997, 76 (11) :1057-1066
[9]  
TRUELOVE JS, 1982, 19 S INT COMB COMB I, P1181
[10]   Investigation of the flow, combustion, heat-transfer and emissions from a 609 MW utility tangentially fired pulverized-coal boiler [J].
Yin, C ;
Caillat, S ;
Harion, JL ;
Baudoin, B ;
Perez, E .
FUEL, 2002, 81 (08) :997-1006