Wearable soft sensing suit for human gait measurement

被引:317
作者
Menguc, Yigit [1 ,2 ]
Park, Yong-Lae [3 ]
Pei, Hao [1 ,2 ]
Vogt, Daniel [1 ,2 ]
Aubin, Patrick M. [1 ,2 ]
Winchell, Ethan [1 ]
Fluke, Lowell [1 ]
Stirling, Leia [4 ]
Wood, Robert J. [1 ,2 ]
Walsh, Conor J. [1 ,2 ]
机构
[1] Harvard Univ, Sch Engn & Appl Sci, Cambridge, MA 02138 USA
[2] Harvard Univ, Wyss Inst Biol Inspired Engn, Boston, MA 02115 USA
[3] Carnegie Mellon Univ, Inst Robot, Pittsburgh, PA 15213 USA
[4] MIT, Dept Aeronaut & Astronaut, Cambridge, MA 02139 USA
关键词
Soft sensors; soft robotics; wearable robotics; wearable electronics; motion capture; STRAIN SENSOR; DESIGN; EXOSKELETON; SKIN; TRANSPARENT; ORIENTATION; PRESSURE; POSITION; TEXTILE;
D O I
10.1177/0278364914543793
中图分类号
TP24 [机器人技术];
学科分类号
080202 ; 1405 ;
摘要
Wearable robots based on soft materials will augment mobility and performance of the host without restricting natural kinematics. Such wearable robots will need soft sensors to monitor the movement of the wearer and robot outside the lab. Until now wearable soft sensors have not demonstrated significant mechanical robustness nor been systematically characterized for human motion studies of walking and running. Here, we present the design and systematic characterization of a soft sensing suit for monitoring hip, knee, and ankle sagittal plane joint angles. We used hyper-elastic strain sensors based on microchannels of liquid metal embedded within elastomer, but refined their design with the use of discretized stiffness gradients to improve mechanical durability. We found that these robust sensors could stretch up to 396% of their original lengths, would restrict the wearer by less than 0.17% of any given joint's torque, had gauge factor sensitivities of greater than 2.2, and exhibited less than 2% change in electromechanical specifications through 1500 cycles of loading-unloading. We also evaluated the accuracy and variability of the soft sensing suit by comparing it with joint angle data obtained through optical motion capture. The sensing suit had root mean square (RMS) errors of less than 5 degrees for a walking speed of 0.89m/s and reached a maximum RMS error of 15 degrees for a running speed of 2.7m/s. Despite the deviation of absolute measure, the relative repeatability of the sensing suit's joint angle measurements were statistically equivalent to that of optical motion capture at all speeds. We anticipate that wearable soft sensing will also have applications beyond wearable robotics, such as in medical diagnostics and in human-computer interaction.
引用
收藏
页码:1748 / 1764
页数:17
相关论文
共 66 条
  • [1] Asbeck Alan T, 2013, IEEE Int Conf Rehabil Robot, V2013, P6650455, DOI 10.1109/ICORR.2013.6650455
  • [2] Bar-Cohen Y., 2004, ELECTROACTIVE POLYM
  • [3] Synergy-based hand pose sensing: Optimal glove design
    Bianchi, Matteo
    Salaris, Paolo
    Bicchi, Antonio
    [J]. INTERNATIONAL JOURNAL OF ROBOTICS RESEARCH, 2013, 32 (04) : 407 - 424
  • [4] Synergy-based hand pose sensing: Reconstruction enhancement
    Bianchi, Matteo
    Salaris, Paolo
    Bicchi, Antonio
    [J]. INTERNATIONAL JOURNAL OF ROBOTICS RESEARCH, 2013, 32 (04) : 396 - 406
  • [5] Estimation of Soft Tissue Mechanical Parameters From Robotic Manipulation Data
    Boonvisut, Pasu
    Cavusoglu, M. Cenk
    [J]. IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2013, 18 (05) : 1602 - 1611
  • [6] Surface-marker cluster design criteria for 3-D bone movement reconstruction
    Cappozzo, A
    Cappello, A
    DellaCroce, U
    Pensalfini, F
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1997, 44 (12) : 1165 - 1174
  • [7] The resonant step frequency in human running
    Cavagna, GA
    Mantovani, M
    Willems, PA
    Musch, G
    [J]. PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1997, 434 (06): : 678 - 684
  • [8] Cavallo Filippo, 2013, IEEE Int Conf Rehabil Robot, V2013, P6650466, DOI 10.1109/ICORR.2013.6650466
  • [9] Microfluidic electronics
    Cheng, Shi
    Wu, Zhigang
    [J]. LAB ON A CHIP, 2012, 12 (16) : 2782 - 2791
  • [10] A Soft Strain Sensor Based on Ionic and Metal Liquids
    Chossat, Jean-Baptiste
    Park, Yong-Lae
    Wood, Robert J.
    Duchaine, Vincent
    [J]. IEEE SENSORS JOURNAL, 2013, 13 (09) : 3405 - 3414